4 research outputs found

    SUB-OCEAN: subsea dissolved methane measurements using an embedded laser spectrometer technology

    Get PDF
    This document is the Accepted Manuscript version of a Published Work that appeared in final form in Environmental Science and Technology, copyright © American Chemical Society after peer review and technical editing by the publisher. To access the final edited and published work see https://doi.org/10.1021/acs.est.7b06171.We present a novel instrument, the Sub-Ocean probe, allowing in situ and continuous measurements of dissolved methane in seawater. It relies on an optical feedback cavity enhanced absorption technique designed for trace gas measurements and coupled to a patent-pending sample extraction method. The considerable advantage of the instrument compared with existing ones lies in its fast response time of the order of 30 s, that makes this probe ideal for fast and continuous 3D-mapping of dissolved methane in water. It could work up to 40 MPa of external pressure and it provides a large dynamic range, from subnmol of CH4 per liter of seawater to mmol L-1. In this work, we present laboratory calibration of the instrument, intercomparison with standard method and field results on methane detection. The good agreement with the headspace equilibration technique followed by gas-chromatography analysis supports the utility and accuracy of the instrument. A continuous 620-m depth vertical profile in the Mediterranean Sea was obtained within only 10 min and it indicates background dissolved CH4 values between 1 and 2 nmol L-1 below the pycnocline, similar to previous observations conducted in different ocean settings. It also reveals a methane maximum at around 6 m of depth that may reflect local production from bacterial transformation of dissolved organic matter

    Frequency stable and low phase noise THz synthesis for precision spectroscopy

    No full text
    International audienceWe present a robust approach to generate a continuously tunable, low phase noise, Hz linewidth and mHz/s stability THz emission in the 0.1 THz to 1.4 THz range. This is achieved by photomixing two commercial telecom, distributed feedback lasers locked by optical-feedback onto a single highly stable V-shaped optical cavity. The phase noise is evaluated up to 1.2 THz, demonstrating Hz-level linewidth. To illustrate the spectral performances and agility of the source, low pressure absorption lines of methanol and water vapors have been recorded up to 1.4 THz. In addition, the hyperfine structure of a water line at 556.9 GHz, obtained by saturation spectroscopy, is also reported, resolving spectral features displaying a full-width at half-maximum of 10 kHz. The present results unambiguously establish the performances of this source for ultra-high resolution molecular physics

    HoSAGE: Sarcopenia in Older Patients before and after Treatment with Androgen Deprivation Therapy and Radiotherapy for Prostate Cancer

    No full text
    International audienceBackground: Sarcopenia is a muscle disease defined by a loss of muscle strength associated to a decrease in skeletal muscle mass. In addition to aging, many factors may contribute to sarcopenia as cancer and/or androgen deprivation therapy (ADT).Objectives: The aims of this study are to describe the prevalence of sarcopenia in older prostate cancer patients before initiation of treatment with ADT and radiotherapy, and to evaluate the impact of ADT on the occurrence or aggravation of sarcopenia in this population.Design: Longitudinal study.Participants and setting: Sarcopenia was prospectively evaluated in 31 consecutive patients aged 70 to 88 years, referred in one hospital unit of south eastern France, for a comprehensive geriatric assessment (CGA) before cancer treatment initiation.Measurements and results: CGA, measures of muscle strength and physical performances were performed at baseline (T0) and at the end of cancer treatment (T1). Appendicular skeletal muscle mass was measured by Dual-energy X-ray absorptiometry (DXA) at the end of treatment. At T0, 8 patients (among 31) had a probable sarcopenia according to European consensus, and 18 had altered physical performance. At T1, 15 patients (among 19) had abnormal one leg balance test. Finally, only one patient had a sarcopenia confirmed by DXA.Conclusion: This preliminary study showed a high prevalence of muscle disorders before initiation of ADT in a population of elderly cancer prostate patients with intermediate frailty status, and an increased risk of falls at the end of ADT. This highlighted the importance of screening for sarcopenia before treatment initiation, to prevent the occurrence or aggravation of sarcopenia by possible adjustment of treatment, and implementation of appropriate exercise and nutrition interventions

    Whole-body MR imaging in suspected physical child abuse: comparison with skeletal survey and bone scintigraphy findings from the PEDIMA prospective multicentre study

    No full text
    International audienceObjectives: To assess the contribution of whole-body magnetic resonance imaging (WBMRI) and bone scintigraphy (BS) in addition to skeletal survey (SS) in detecting traumatic bone lesions and soft-tissue injuries in suspected child abuse.Methods: In this prospective, multicentre, diagnostic accuracy study, children less than 3 years of age with suspected physical abuse were recruited. Each child underwent SS, BS and WBMRI. A blinded first review was performed in consensus by five paediatric radiologists and three nuclear medicine physicians. A second review investigated discrepancies reported between the modalities using a consensus result of all modalities as the reference standard. We calculated the sensitivity, specificity and corresponding 95% confidence interval for each imaging modality (SS, WBMRI and BS) and for the combinations [SS + WBMRI] and [SS + BS].Results: One hundred seventy children were included of which sixty-four had at least one lesion. In total, 146 lesions were included. The sensitivity and specificity of each examination were, respectively, as follows: 88.4% [95% CI, 82.0-93.1] and 99.7% [95% CI, 99.5-99.8] for the SS, 69.9% [95% CI, 61.7-77.2] and 99.5% [95% CI, 99.2-99.7] for WBMRI and 54.8% [95% CI, 46.4-63.0] and 99.7% [95% CI, 99.5-99.9] for BS. Sensitivity and specificity were, respectively, 95.9% [95% CI, 91.3-98.5] and 99.2% [95% CI, 98.9-99.4] for the combination SS + WBMRI and 95.2% [95% CI, 90.4-98.1] and 99.4% [95% CI, 99.2-99.6] for the combination SS + BS, with no statistically significant difference between them.Conclusion: SS was the most sensitive independent imaging modality; however, the additional combination of either WBMRI or BS examinations offered an increased accuracy.Key points: • SS in suspected infant abuse was the most sensitive independent imaging modality in this study, especially for detecting metaphyseal and rib lesions, and remains essential for evaluation. • The combination of either SS + BS or SS + WBMRI provides greater accuracy in diagnosing occult and equivocal bone injuries in the difficult setting of child abuse. • WBMRI is a free-radiation technique that allows additional diagnosis of soft-tissue and visceral injuries
    corecore