342 research outputs found

    Development of a Portable Device for Thermoelectrical Power Measurement—Application to the Inspection of Duplex Stainless Steel Components

    Get PDF
    Some cast components of the primary loop of French Pressurized Water Reactors are made of cast duplex stainless steels. The mechanical characteristics of these components, working in the temperature range from 285°C to 325°C, may be altered by thermal aging : the hardness of the materials increases whereas its toughness decreases with aging time and temperature. The metallurgical explanation of this phenomena is the unmixing of the ferritic Fe-Cr-Ni solid solution by spinodal decomposition and the precipitation of intermetallic G-phase particles rich in nickel and silicium [1]

    Poisoning by non-edible squash: retrospective series of 353 patients from French Poison Control Centers

    Get PDF
    CONTEXT: Among the numerous varieties of squash that exist, some are edible while other bitter-tasting ones are not fit for human consumption. Cases of confusion seem to be multiplying and are characterized by digestive problems (diarrhea, vomiting, and abdominal pain). METHODS: This is a descriptive retrospective study of cases of exposure reported to French Poison Control Centers between 1 January 2012 and 12 December 2016. RESULTS: 353 patients were included, with 71.7% belonging to collective cases of poisoning. The male to female sex ratio was 0.75 for an average age of 38.2 ± 23.6 years. The circumstances of exposure were dietary for 337 patients (95.5%). The majority of the squash consumed was purchased at a store (55.8%) but some also came from the garden (25.5%). 204 patients (57.8%) mostly presented with diarrhea, vomiting, abdominal pain, sometimes with the consequent dehydration, hypotension, tachycardia, headaches, or vertigo. There were no deaths or severe (Poisoning Severity Score (PSS) 3) cases, but there were 14 patients (4.0%) of moderate severity, 190 patients (53.8%) of minor severity (PSS 1), and 149 patients (42.2%) without severity (PSS 0) but among which we include the bitter taste of the squash. The average age of PSS 2 patients was significantly (p = .003) older than that of the PSS <2 patients. CONCLUSION: As the first consequential series in Europe, our study shows that exposure to non-edible squash is frequent. Usually benign, poisoning could be the consequence of the irritating effect of certain cucurbits, the molecules responsible for the taste and toxicity of the fruits. In terms of prevention therefore, we recommend disposing of any squash with a bitter taste

    Accumulation of Immature Langerhans Cells in Human Lymph Nodes Draining Chronically Inflamed Skin

    Get PDF
    The coordinated migration and maturation of dendritic cells (DCs) such as intraepithelial Langerhans cells (LCs) is considered critical for T cell priming in response to inflammation in the periphery. However, little is known about the role of inflammatory mediators for LC maturation and recruitment to lymph nodes in vivo. Here we show in human dermatopathic lymphadenitis (DL), which features an expanded population of LCs in one draining lymph node associated with inflammatory lesions in its tributary skin area, that the Langerin/CD207+ LCs constitute a predominant population of immature DCs, which express CD1a, and CD68, but not CD83, CD86, and DC–lysosomal-associated membrane protein (LAMP)/CD208. Using LC-type cells generated in vitro in the presence of transforming growth factor (TGF)-β1, we further found that tumor necrosis factor (TNF)-α, as a prototype proinflammatory factor, and a variety of inflammatory stimuli and bacterial products, increase Langerin expression and Langerin dependent Birbeck granules formation in cell which nevertheless lack costimulatory molecules, DC–LAMP/CD208 and potent T cell stimulatory activity but express CCR7 and respond to the lymph node homing chemokines CCL19 and CCL21. This indicates that LC migration and maturation can be independently regulated events. We suggest that during DL, inflammatory stimuli in the skin increase the migration of LCs to the lymph node but without associated maturation. Immature LCs might regulate immune responses during chronic inflammation

    A voltage-based approach for series high impedance fault detection and location in distribution systems using smart meters

    Get PDF
    High impedance faults (HIFs) have been a major concern for protecting distribution systems and public safety hazards when involving downed conductors. The deployment of smarter grids brings new technologies for smart monitoring, automation, and protection of distribution networks. This paper presents a new method for a series of HIF detection and location in primary distribution feeders, using voltage unbalance measurements collected from smart meters (SMs) installed at low-voltage end-users. The methodology was tested in MATLAB and Simulink through steady-state simulations of a typical 13.8 kV distribution system, under load unbalance and di erent fault scenarios. Results show that the proposed method is robust and accurate for the detection of blown fuses and broken conductors, with or without ground faults, located either at the source or the load-side. The ease of implementation in SM design, formulation of parameters, and reliable simulation results show potential real-life applications

    The XMM-Newton Wide-Field Survey in the COSMOS field (XMM-COSMOS): demography and multiwavelength properties of obscured and unobscured luminous AGN

    Get PDF
    We report the final optical identifications of the medium-depth (~60 ksec), contiguous (2 deg^2) XMM-Newton survey of the COSMOS field. XMM-Newton has detected ~800 X-ray sources down to limiting fluxes of ~5x10^{-16}, ~3x10^{-15}, and ~7x10^{-15} erg/cm2/s in the 0.5-2 keV, 2-10 keV and 5-10 keV bands, respectively. The work is complemented by an extensive collection of multi-wavelength data from 24 micron to UV, available from the COSMOS survey, for each of the X-ray sources, including spectroscopic redshifts for ~50% of the sample, and high-quality photometric redshifts for the rest. The XMM and multiwavelength flux limits are well matched: 1760 (98%) of the X-ray sources have optical counterparts, 1711 (~95%) have IRAC counterparts, and 1394 (~78%) have MIPS 24micron detections. Thanks to the redshift completeness (almost 100%) we were able to constrain the high-luminosity tail of the X-ray luminosity function confirming that the peak of the number density of logL_X>44.5 AGN is at z~2. Spectroscopically-identified obscured and unobscured AGN, as well as normal and starforming galaxies, present well-defined optical and infrared properties. We devised a robust method to identify a sample of ~150 high redshift (z>1), obscured AGN candidates for which optical spectroscopy is not available. We were able to determine that the fraction of the obscured AGN population at the highest (L_X>10^{44} erg s^{-1}) X-ray luminosity is ~15-30% when selection effects are taken into account, providing an important observational constraint for X-ray background synthesis. We studied in detail the optical spectrum and the overall spectral energy distribution of a prototypical Type 2 QSO, caught in a stage transitioning from being starburst dominated to AGN dominated, which was possible to isolate only thanks to the combination of X-ray and infrared observations.Comment: ApJ, in press. 59 pages, 14 figures, 2 Tables. A few typos corrected and a reference added. Table 2 is also available at http://www.mpe.mpg.de/XMMCosmos/xmm53_release ; a version of the paper in ApJ format (27 pages) is available at http://www.mpe.mpg.de/XMMCosmos/xmm53_release/brusa_xmmcosmos_optid.pd

    Hypofractionated radiotherapy has the potential for second cancer reduction

    Get PDF
    <p>Abstract</p> <p>Background and Purpose</p> <p>A model for carcinoma and sarcoma induction was used to study the dependence of carcinogenesis after radiotherapy on fractionation.</p> <p>Materials and methods</p> <p>A cancer induction model for radiotherapy doses including fractionation was used to model carcinoma and sarcoma induction after a radiation treatment. For different fractionation schemes the dose response relationships were obtained. Tumor induction was studied as a function of dose per fraction.</p> <p>Results</p> <p>If it is assumed that the tumor is treated up to the same biologically equivalent dose it was found that large dose fractions could decrease second cancer induction. The risk decreases approximately linear with increasing fraction size and is more pronounced for sarcoma induction. Carcinoma induction decreases by around 10% per 1 Gy increase in fraction dose. Sarcoma risk is decreased by about 15% per 1 Gy increase in fractionation. It is also found that tissue which is irradiated using large dose fractions to dose levels lower than 10% of the target dose potentially develop less sarcomas when compared to tissues irradiated to all dose levels. This is not observed for carcinoma induction.</p> <p>Conclusions</p> <p>It was found that carcinoma as well as sarcoma risk decreases with increasing fractionation dose. The reduction of sarcoma risk is even more pronounced than carcinoma risk. Hypofractionation is potentially beneficial with regard to second cancer induction.</p

    Precision photometric redshift calibration for galaxy-galaxy weak lensing

    Get PDF
    Accurate photometric redshifts are among the key requirements for precision weak lensing measurements. Both the large size of the Sloan Digital Sky Survey (SDSS) and the existence of large spectroscopic redshift samples that are flux-limited beyond its depth have made it the optimal data source for developing methods to properly calibrate photometric redshifts for lensing. Here, we focus on galaxy-galaxy lensing in a survey with spectroscopic lens redshifts, as in the SDSS. We develop statistics that quantify the effect of source redshift errors on the lensing calibration and on the weighting scheme, and show how they can be used in the presence of redshift failure and sampling variance. We then demonstrate their use with 2838 source galaxies with spectroscopy from DEEP2 and zCOSMOS, evaluating several public photometric redshift algorithms, in two cases including a full p(z) for each object, and find lensing calibration biases as low as <1 per cent (due to fortuitous cancellation of two types of bias) or as high as 20 per cent for methods in active use (despite the small mean photoz bias of these algorithms). Our work demonstrates that lensing-specific statistics must be used to reliably calibrate the lensing signal, due to asymmetric effects of (frequently non-Gaussian) photoz errors. We also demonstrate that large-scale structure (LSS) can strongly impact the photoz calibration and its error estimation, due to a correlation between the LSS and the photoz errors, and argue that at least two independent degree-scale spectroscopic samples are needed to suppress its effects. Given the size of our spectroscopic sample, we can reduce the galaxy-galaxy lensing calibration error well below current SDSS statistical error

    Precision photometric redshift calibration for galaxy–galaxy weak lensing

    Get PDF
    Accurate photometric redshifts are among the key requirements for precision weak lensing measurements. Both the large size of the Sloan Digital Sky Survey (SDSS) and the existence of large spectroscopic redshift samples that are flux-limited beyond its depth have made it the optimal data source for developing methods to properly calibrate photometric redshifts for lensing. Here, we focus on galaxy–galaxy lensing in a survey with spectroscopic lens redshifts, as in the SDSS. We develop statistics that quantify the effect of source redshift errors on the lensing calibration and on the weighting scheme, and show how they can be used in the presence of redshift failure and sampling variance. We then demonstrate their use with 2838 source galaxies with spectroscopy from DEEP2 and zCOSMOS, evaluating several public photometric redshift algorithms, in two cases including a full p(z) for each object, and find lensing calibration biases as low as <1 per cent (due to fortuitous cancellation of two types of bias) or as high as 20 per cent for methods in active use (despite the small mean photoz bias of these algorithms). Our work demonstrates that lensing-specific statistics must be used to reliably calibrate the lensing signal, due to asymmetric effects of (frequently non-Gaussian) photoz errors. We also demonstrate that large-scale structure (LSS) can strongly impact the photoz calibration and its error estimation, due to a correlation between the LSS and the photoz errors, and argue that at least two independent degree-scale spectroscopic samples are needed to suppress its effects. Given the size of our spectroscopic sample, we can reduce the galaxy–galaxy lensing calibration error well below current SDSS statistical errors

    Percutaneous coronary intervention in asians- are there differences in clinical outcome?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ethnic differences in clinical outcome after percutaneous coronary intervention (PCI) have been reported. Data within different Asian subpopulations is scarce. We aim to explore the differences in clinical profile and outcome between Chinese, Malay and Indian Asian patients who undergo PCI for coronary artery disease (CAD).</p> <p>Methods</p> <p>A prospective registry of consecutive patients undergoing PCI from January 2002 to December 2007 at a tertiary care center was analyzed. Primary endpoint was major adverse cardiovascular events (MACE) of myocardial infarction (MI), repeat revascularization and all-cause death at six months.</p> <p>Results</p> <p>7889 patients underwent PCI; 7544 (96%) patients completed follow-up and were included in the analysis (79% males with mean age of 59 years ± 11). There were 5130 (68%) Chinese, 1056 (14%) Malays and 1001 (13.3%) Indian patients. The remaining 357 (4.7%) patients from other minority ethnic groups were excluded from the analysis. The primary end-point occurred in 684 (9.1%) patients at six months. Indians had the highest rates of six month MACE compared to Chinese and Malays (Indians 12% vs. Chinese 8.2% vs. Malays 10.7%; OR 1.55 95%CI 1.24-1.93, p < 0.001). This was contributed by increased rates of MI (Indians 1.9% vs. Chinese 0.9% vs. Malays 1.3%; OR 4.49 95%CI 1.91-10.56 p = 0.001), repeat revascularization (Indians 6.5% vs. Chinese 4.1% vs. Malays 5.1%; OR 1.64 95%CI 1.22-2.21 p = 0.0012) and death (Indians 11.4% vs. Chinese 7.6% vs. Malays 9.9%; OR 1.65 95%CI 1.23-2.20 p = 0.001) amongst Indian patients.</p> <p>Conclusion</p> <p>These data indicate that ethnic variations in clinical outcome exist following PCI. In particular, Indian patients have higher six month event rates compared to Chinese and Malays. Future studies are warranted to elucidate the underlying mechanisms behind these variations.</p
    corecore