75 research outputs found

    The biocompatibility of titanium in a buffer solution: compared effects of a thin film of TiO2 deposited by MOCVD and of collagen deposited from a gel

    Get PDF
    This study aims at evaluating the biocompatibility of titanium surfaces modified according two different ways: (i) deposition of a bio-inert, thin film of rutile TiO2 by chemical vapour deposition (MOCVD), and (ii) biochemical treatment with collagen gel, in order to obtain a bio-interactive coating. Behind the comparison is the idea that either the bio-inert or the bio-active coating has specific advantages when applied to implant treatment, such as the low price of the collagen treatment for instance. The stability in buffer solution was evaluated by open circuit potential (OCP) for medium time and cyclic voltametry. The OCP stabilized after 5104 min for all the specimens except the collagen treated sample which presented a stable OCP from the first minutes. MOCVD treated samples stabilized to more electropositive values. Numeric results were statistically analysed to obtain the regression equations for long time predictable evolution. The corrosion parameters determined from cyclic curves revealed that the MOCVD treatment is an efficient way to improve corrosion resistance. Human dermal fibroblasts were selected for cell culture tests, taking into account that these cells are present in all bio-interfaces, being the main cellular type of connective tissue. The cells grew on either type of surface without phenotype modification. From the reduction of yellow, water-soluble 3-(4,5-dimethyldiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT cytotoxicity test), MOCVD treated samples offer better viability than mechanically polished Ti and collagen treated samples as well. Cell spreading, as evaluated from microscope images processed by the program Sigma Scan, showed also enhancement upon surface modification. Depending on the experimental conditions, MOCVD deposited TiO2 exhibits different nanostructures that may influence biological behaviour. The results demonstrate the capacity of integration in simulated physiologic liquids for an implant pretreated by either method

    In vitro kinetic study of growth and mineralization of osteoblast-like cells (Saos-2) on titanium surface coated with a RGD functionalized bisphosphonate

    Get PDF
    Osteoconduction and osseointegration are the critical stages for implantation success. Peptides containing RGD (Arg-Gly-Asp) adhesive sequence are known to promote cell adhesion and consequently to favor osseointegration of medical devices. In this study, RGD peptides were coupled to a bisphosphonate used as an anchor system and chemically adsorbed on polished titanium discs. Two different concentrations, 10−10 mol/L (RGD 10−10) and 10−4 mol/L (RGD 10−4) were compared to non coated discs (RGD 0). Adhesion, spreading, and mineralization of osteoblast-like cells (Saos-2) were assessed. Mineralization kinetic was done at 3, 6, 10, 14, and 18 days of culture; the extent of mineral deposits was quantified by image analysis. Histogram repartitions of nuclear area, characterizing cell spreading, showed a shift to higher values in cells cultured on RGD coated titanium disks. Mineralization started at day 3 in the three groups, but had a faster development in the RGD 10−10 group from day 6 to day 18 compared to RGD 0 and RGD 10−4. At day 18, the percentage of mineralized area was significantly higher for RGD 10−10 compared to RGD 0 (p < 0.05). In the present study, this new method was found suitable to anchor RGD containing species on titanium: this favored adhesion and spreading of osteoblast-like cells and mineralization compared to noncoated titanium

    Corrosion behaviour of micro-plasma arc welded stainless steels in H3PO4 under flowing conditions at different temperatures

    Full text link
    [EN] This paper studies the general corrosion behaviour of the micro-plasma arc welded AISI 316L stainless steel in phosphoric acid at different temperatures (25-60°C) and at a Reynolds number of 1456. Galvanic corrosion has been studied using zero-resistance ammeter (ZRA) measurements and polarization curves (by the mixed potential theory). Results show that the microstructure of the stainless steel is modified due to the micro-plasma arc welding procedure. Coupled current density values obtained from polarization curves increase with temperature. ZRA tests present the highest iG values at 60°C; however, the values are very close to zero for all the temperatures studied. This is in agreement with the low value of the compatibility limit and of the parameter which evaluates the importance of the galvanic phenomenon. Both techniques present the most positive potentials at the highest temperature. This study reveals that micro-plasma arc welded AISI 316L stainless steels are appropriated working in the studied H3PO4 media from a corrosion point of view for all the temperatures analysedThe authors would like to express their gratitude to the Spanish MAEC (PCI Mediterráneo C/8196/07, C/018046/08, D/023608/09) and to Asuncion Jaime for her translation assistance.Sánchez Tovar, R.; Montañés Sanjuan, MT.; García Antón, J.; Guenbour, A.; Ben Bachir, A. (2011). Corrosion behaviour of micro-plasma arc welded stainless steels in H3PO4 under flowing conditions at different temperatures. Corrosion Science. 53(4):1237-1246. https://doi.org/10.1016/j.corsci.2010.12.017S1237124653

    Corrosion resistance of ZrTi alloys with hydroxyapatite-zirconia silver layer in simulated physiological solution containing proteins for biomaterial applications

    Get PDF
    The degradation characteristics of hydroxyapatite-zirconia-silver films (HA-ZrO2-Ag) coatings on three ZrTi alloys were investigated in Ringer’s solution containing 10% human albumin protein at 37 °C. Samples were immersed for 7 days while monitored by electrochemical impedance spectroscopy (EIS) and linear potentiodynamic polarization (LPP). The electrochemical analysis in combination with surface analytical characterization by scanning electron microscopy (SEM/EDX) reveals the stability and corrosion resistance of the HA–ZrO2-Ag coated ZrTi alloys. The characteristic feature that describes the electrochemical behaviour of the coated alloys is the coexistence of large areas of the coating presenting pores in which the ZrTi alloy substrate is exposed to the simulated physiological environment. The EIS interpretation of results was thus performed using a two-layer model of the surface film. The blocking effect in the presence the human albumin protein produces an enhancement of the corrosion resistance. The results disclose that the Zr45Ti alloy is a promising material for biomedical devices, since electrochemical stability is directly associated to biocompatibilit

    A study of histological responses from Ti-6Al-7Nb alloy dental implants with and without plasma-sprayed hydroxyapatite coating in dogs

    No full text
    Titanium alloys are hoped to be used much more for applications as implant materials in the medical and dental fields because of their basic properties, such as biocompatibility, corrosion resistance and specific strength compared with other metallic implant materials. Thus, the Ti-6Al-7Nb alloy that has recently been developed for biomedical use, that is, primarily developed for orthopaedic use, is to be studied in this paper, for application in dental implants. The biocompatibility test in vivo was carried out in dogs and the osseointegration was verified through histological analysis of the samples of the Ti-6Al-7Nb alloy with and without hydroxyapatite coating that were inserted in the alveoli. Within the controlled conditions the samples did not show any toxic effects on the cells. (C) 2001 Kluwer Academic Publishers.12327327

    Electrochemical impedance spectroscopy characterization of passive film formed on implant Ti-6Al-7Nb alloy in Hank's solution

    No full text
    The influence of potential on electrochemical behavior of Ti-6Al-7Nb alloy under simulate physiological conditions was investigated by electrochemical impedance spectroscopy (EIS). The experimental results were compared with those obtained by potentiodynamic polarization curves. All measurements were carried out in Hank's aerated solution at 25degreesC, at pH 7.8 and at different potentials (corrosion potential, 0 mV(SCE), 1000 mV(SCE), and 2000 mV(SCE)). The EIS spectra exhibited a two-step or a two-time constant system, suggesting the formation of a two-layer oxide film on the metal surface. The high corrosion resistance, displayed by this alloy in electrochemical polarization tests, is due to the dense inner layer, while its osseointegration ability can be ascribed to the presence of the outer porous layer. (C) 2004 Kluwer Academic Publishers
    corecore