1,422 research outputs found

    In My View

    Get PDF

    Experience with covered stents for the management of hemodialysis polytetrafluoroethylene graft seromas

    Get PDF
    Prosthetic graft seromas is a rare complication that has been traditionally managed with open methods using partial graft replacement and open drainage. We report the first two cases of hemodialysis graft seromas successfully treated with a covered stent. Both patients underwent arteriovenous graft placement from the brachial artery to the axillary vein using a standard wall, tapered 4 to 7 mm polytetrafluoroethylene graft, but developed a seroma at the arterial end of the graft. Unsuccessful attempts were made to treat these seromas with percutaneous and open drainage. In both patients, an 8 mm × 50 mm Wallgraft (Boston Scientific, Natick, Mass) was retrogradely deployed “bareback” at the arterial end of the graft allowing for complete resolution of the graft seromas

    Is elevated creatinine level a contraindication to endovascular aneurysm repair?

    Get PDF
    AbstractPurposeIt is widely believed that chronic renal insufficiency (CRI) greatly increases the risk associated with endovascular abdominal aortic aneurysm repair (EVAR) and is a relative contraindication to the procedure and to the use of intra-arterial contrast agents (IACA). We reviewed a 5-year EVAR experience to determine whether the procedure and use of IACA have an important deleterious effect on renal function in patients with and without pre-existing CRI.MethodsEndovascular aneurysm repair (EVAR) was performed in 200 patients with a variety of endografts, with intra-arterial contrast agents. The patients were retrospectively assigned to three groups on the basis of preoperative serum creatinine concentration (Cr): group 1 (n = 108), Cr less than 1.5 mg/dL (normal range); group 2 (n = 65), Cr 1.5 to 2.0 mg/dL; group 3 (n = 27), Cr 2.1 to 3.5 mg/dL. No patients had undergone hemodialysis. In groups 2 and 3, patients received hydration perioperatively, and received mannitol intraoperatively; no nephrotoxic drugs were administered during the procedure, other than nonionic contrast agent (Omnipaque 350).ResultsThe incidence of postoperative complications between the three study groups was not statistically different. In group 1 a transient increase in serum Cr (>30% over baseline and >1.4 mg/dL) was noted in three patients (2.7%), two of whom (1.9%) required temporary hemodialysis and one (0.9%) who died of renal failure. In group 2 a transient increase in serum Cr was noted in two patients (3.1%); both patients (3.1%) required temporary hemodialysis, and one patient (1.5%) died of renal failure. In group 3 a transient increase in serum Cr was noted in two patients (7.4%); one patient (3.7%) required temporary hemodialysis, and one patient (3.7%) died of renal failure. Perioperative hypotension significantly increased the risk for elevated serum Cr and death (P < .05), and larger contrast volume was associated with an increase in serum Cr (P < .05) during the postoperative period.ConclusionsEVAR with intra-arterial contrast agents can be accomplished in patients with chronic renal insufficiency who do not require dialysis, with limited and acceptable morbidity and mortality, similar to that observed with open aneurysm repair. Contrary to other reports in which perioperative precautions were not used, our study shows that with EVAR the risk for worsening renal failure, dialysis, and death is only slightly, and not significantly, greater in patients with preoperative chronic renal insufficiency compared with patients with normal renal function. Perioperative hypotension and increased contrast volume are significant risk factors for postoperative increase in serum Cr and death. With appropriate precautions such as averting perioperative hypotension and limiting the volume of nonionic contrast agents, elevated Cr need not be a contraindication to EVAR with intra-arterial contrast agents

    Comparison of techniques for handling missing covariate data within prognostic modelling studies: a simulation study

    Get PDF
    Background: There is no consensus on the most appropriate approach to handle missing covariate data within prognostic modelling studies. Therefore a simulation study was performed to assess the effects of different missing data techniques on the performance of a prognostic model. Methods: Datasets were generated to resemble the skewed distributions seen in a motivating breast cancer example. Multivariate missing data were imposed on four covariates using four different mechanisms; missing completely at random (MCAR), missing at random (MAR), missing not at random (MNAR) and a combination of all three mechanisms. Five amounts of incomplete cases from 5% to 75% were considered. Complete case analysis (CC), single imputation (SI) and five multiple imputation (MI) techniques available within the R statistical software were investigated: a) data augmentation (DA) approach assuming a multivariate normal distribution, b) DA assuming a general location model, c) regression switching imputation, d) regression switching with predictive mean matching (MICE-PMM) and e) flexible additive imputation models. A Cox proportional hazards model was fitted and appropriate estimates for the regression coefficients and model performance measures were obtained. Results: Performing a CC analysis produced unbiased regression estimates, but inflated standard errors, which affected the significance of the covariates in the model with 25% or more missingness. Using SI, underestimated the variability; resulting in poor coverage even with 10% missingness. Of the MI approaches, applying MICE-PMM produced, in general, the least biased estimates and better coverage for the incomplete covariates and better model performance for all mechanisms. However, this MI approach still produced biased regression coefficient estimates for the incomplete skewed continuous covariates when 50% or more cases had missing data imposed with a MCAR, MAR or combined mechanism. When the missingness depended on the incomplete covariates, i.e. MNAR, estimates were biased with more than 10% incomplete cases for all MI approaches. Conclusion: The results from this simulation study suggest that performing MICE-PMM may be the preferred MI approach provided that less than 50% of the cases have missing data and the missing data are not MNAR

    The increase of the functional entropy of the human brain with age

    Get PDF
    We use entropy to characterize intrinsic ageing properties of the human brain. Analysis of fMRI data from a large dataset of individuals, using resting state BOLD signals, demonstrated that a functional entropy associated with brain activity increases with age. During an average lifespan, the entropy, which was calculated from a population of individuals, increased by approximately 0.1 bits, due to correlations in BOLD activity becoming more widely distributed. We attribute this to the number of excitatory neurons and the excitatory conductance decreasing with age. Incorporating these properties into a computational model leads to quantitatively similar results to the fMRI data. Our dataset involved males and females and we found significant differences between them. The entropy of males at birth was lower than that of females. However, the entropies of the two sexes increase at different rates, and intersect at approximately 50 years; after this age, males have a larger entropy

    Structure calculation, refinement and validation using CcpNmr Analysis

    Get PDF
    CcpNmr Analysis provides a streamlined pipeline for both NMR chemical shift assignment and structure determination of biological macromolecules. In addition, it encompasses tools to analyse the many additional experiments that make NMR such a pivotal technique for research into complex biological questions. This report describes how CcpNmr Analysis can seamlessly link together all of the tasks in the NMR structure-determination process. It details each of the stages from generating NMR restraints [distance, dihedral,hydrogen bonds and residual dipolar couplings (RDCs)],exporting these to and subsequently re-importing them from structure-calculation software (such as the programs CYANA or ARIA) and analysing and validating the results obtained from the structure calculation to, ultimately, the streamlined deposition of the completed assignments and the refined ensemble of structures into the PDBe repository. Until recently, such solution-structure determination by NMR has been quite a laborious task, requiring multiple stages and programs. However, with the new enhancements to CcpNmr Analysis described here, this process is now much more intuitive and efficient and less error-prone

    Does Increased Arterial Stiffness Increase the Risk for Postural Hypotension?

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/75516/1/j.1076-7460.2005.04503.x.pd
    • …
    corecore