2,713 research outputs found
Photonic crystal resonator integrated in a microfluidic system
We report on a novel optofluidic system consisting of a silica-based 1D
photonic crystal, integrated planar waveguides and electrically insulated
fluidic channels. An array of pillars in a microfluidic channel designed for
electrochromatography is used as a resonator for on-column label-free
refractive index detection. The resonator was fabricated in a silicon
oxynitride platform, to support electroosmotic flow, and operated at 1.55
microns. Different aqueous solutions of ethanol with refractive indices ranging
from n = 1.3330 to 1.3616 were pumped into the column/resonator and the
transmission spectra were recorded. Linear shifts of the resonant wavelengths
yielded a maximum sensitivity of 480 nm/RIU and a minimum difference of 0.007
RIU was measured
Uniaxial and biaxial soft deformations of nematic elastomers
We give a geometric interpretation of the soft elastic deformation modes of
nematic elastomers, with explicit examples, for both uniaxial and biaxial
nematic order. We show the importance of body rotations in this non-classical
elasticity and how the invariance under rotations of the reference and target
states gives soft elasticity (the Golubovic and Lubensky theorem). The role of
rotations makes the Polar Decomposition Theorem vital for decomposing general
deformations into body rotations and symmetric strains. The role of the square
roots of tensors is discussed in this context and that of finding explicit
forms for soft deformations (the approach of Olmsted).Comment: 10 pages, 10 figures, RevTex, AmsTe
Latent regulatory potential of human-specific repetitive elements
At least half of the human genome is derived from repetitive elements, which are often lineage specific and silenced by a variety of genetic and epigenetic mechanisms. Using a transchromosomic mouse strain that transmits an almost complete single copy of human chromosome 21 via the female germline, we show that a heterologous regulatory environment can transcriptionally activate transposon-derived human regulatory regions. In the mouse nucleus, hundreds of locations on human chromosome 21 newly associate with activating histone modifications in both somatic and germline tissues, and influence the gene expression of nearby transcripts. These regions are enriched with primate and human lineage-specific transposable elements, and their activation corresponds to changes in DNA methylation at CpG dinucleotides. This study reveals the latent regulatory potential of the repetitive human genome and illustrates the species specificity of mechanisms that control it
Acoustic resonances in microfluidic chips: full-image micro-PIV experiments and numerical simulations
We show that full-image micro-PIV analysis in combination with images of
transient particle motion is a powerful tool for experimental studies of
acoustic radiation forces and acoustic streaming in microfluidic chambers under
piezo-actuation in the MHz range. The measured steady-state motion of both
large 5 um and small 1 um particles can be understood in terms of the acoustic
eigenmodes or standing ultra-sound waves in the given experimental
microsystems. This interpretation is supported by numerical solutions of the
corresponding acoustic wave equation.Comment: RevTex, 10 pages, 9 eps figures; NOTE first authors changed his name
to S. Melker Hagsater in the published versio
Electrocardiographic changes during continuous intravenous application of bupivacaine in neonatal pigs
Background It is controversial as to whether T-wave elevation is caused by local anaesthetics, epinephrine, or their combination. It has been shown that T-elevation after intravascular injection of a small bupivacaine test dose is caused by epinephrine and not by bupivacaine. The aim of this study was to investigate ECG changes with higher doses of i.v. bupivacaine. Methods Thirty neonatal pigs were anaesthetized with sevoflurane and their tracheas intubated and artificially ventilated. Under steady-state conditions, bupivacaine was continuously infused (flow rate 3.2 ml kg−1 min−1) by a syringe infusion pump through a central venous catheter. Group 1 received bupivacaine 0.125%, Group 2 bupivacaine 0.5%. The ECG was continuously printed and subsequently analysed for alterations in heart rate, ventricular de- and repolarization, and arrhythmias at 1.25, 2.5, and 5 mg kg−1 bupivacaine infused. Results Sinus rhythm persisted in all pigs. Heart rate decreased progressively in both groups, but this was significantly more pronounced in Group 1. T-wave elevation occurred in 40% and 0% (Groups 1 and 2) at 1.25 mg kg−1, in 80% and 0% at 2.5 mg kg−1, and in 93% and 80% at 5 mg kg−1 bupivacaine infused. There were significant differences between the two groups at 1.25 and 2.5 mg kg−1 infused. Conclusions Higher doses of i.v. infused bupivacaine can cause T-elevation. With slower injection technique, T-elevation can already be detected at lower bupivacaine doses administere
Integration of a zero dead-volume PDMS rotary switch valve in a miniaturised (bio)electroanalytical system
This work features the design, fabrication and characterisation of a miniaturised electroanalytical lab on a chip that allows the performance of a complete bioassay, from the capture of magnetic particles through their functionalisation and sample incubation to the detection of electroactive reaction products. The system is built using mainly polymeric materials such as PMMA and PDMS and fast prototyping techniques such as milling and moulding. The system also includes a set of microelectrodes, photo-lithographed on a silicon chip. The novelty lies in the design of the rotary microvalve, which contains a microreactor so that various reaction and incubation steps can be carried out in isolation from the detection event with zero dead volume. This avoids contamination and fouling of the electrodes by proteins or other organic matter, and extends the useful lifetime of the detector. The system operation is demonstrated by a model example, consisting in the functionalisation of streptavidin-coated magnetic particles with biotinylated β-galactosidase over periods ranging from 5 to 15 minutes, at which point the particles saturate. Although the system is intended for the development of enzyme-based electrochemical bioassays, the concept of its rotary microreactor can be applied more broadly.Peer reviewe
Mechanical response of plectonemic DNA: an analytical solution
We consider an elastic rod model for twisted DNA in the plectonemic regime.
The molecule is treated as an impenetrable tube with an effective, adjustable
radius. The model is solved analytically and we derive formulas for the contact
pressure, twisting moment and geometrical parameters of the supercoiled region.
We apply our model to magnetic tweezer experiments of a DNA molecule subjected
to a tensile force and a torque, and extract mechanical and geometrical
quantities from the linear part of the experimental response curve. These
reconstructed values are derived in a self-contained manner, and are found to
be consistent with those available in the literature.Comment: 14 pages, 4 figure
Scintillator counters with WLS fiber/MPPC readout for the side muon range detector (SMRD)of the T2K experiment
The T2K neutrino experiment at J-PARC uses a set of near detectors to measure
the properties of an unoscillated neutrino beam and neutrino interaction
cross-sections. One of the sub-detectors of the near-detector complex, the side
muon range detector (SMRD), is described in the paper. The detector is designed
to help measure the neutrino energy spectrum, to identify background and to
calibrate the other detectors. The active elements of the SMRD consist of 0.7
cm thick extruded scintillator slabs inserted into air gaps of the UA1 magnet
yokes. The readout of each scintillator slab is provided through a single WLS
fiber embedded into a serpentine shaped groove. Two Hamamatsu multi-pixel
avalanche photodiodes (MPPC's) are coupled to both ends of the WLS fiber. This
design allows us to achieve a high MIP detection efficiency of greater than
99%. A light yield of 25-50 p.e./MIP, a time resolution of about 1 ns and a
spatial resolution along the slab better than 10 cm were obtained for the SMRD
counters.Comment: 7 pages, 4 figures; talk at TIPP09, March 12-17, Tsukuba, Japan; to
be published in the conference proceeding
Settled Cryogenic Propellant Transfer
Cryogenic propellant transfer can significantly benefit NASA s space exploration initiative. LMSSC parametric studies indicate that "Topping off" the Earth Departure Stage (EDS) in LEO with approx.20 mT of additional propellant using cryogenic propellant transfer increases the lunar delivered payload by 5 mT. Filling the EDS to capacity in LEO with 78 mT of propellants increases the delivered payload by 20 mT. Cryogenic propellant transfer is directly extensible to Mars exploration in that it provides propellant for the Mars Earth Departure stage and in-situ propellant utilization at Mars. To enable the significant performance increase provided by cryogenic propellant transfer, the reliability and robustness of the transfer process must be guaranteed. By utilizing low vehicle acceleration during the cryogenic transfer the operation is significantly simplified and enables the maximum use of existing, reliable, mature upper stage cryogenic-fluid-management (CFM) techniques. Due to settling, large-scale propellant transfer becomes an engineering effort, and not the technology development endeavor required with zero-gravity propellant transfer. The following key CFM technologies are all currently implemented by settling on both the Centaur and Delta IV upper stages: propellant acquisition, hardware chilldown, pressure control, and mass gauging. The key remaining technology, autonomous rendezvous and docking, is already in use by the Russians, and must be perfected for NASA whether the use of propellant transfer is utilized or not
- …
