1,334 research outputs found

    Controlled Environmental Effects on Creep Test Data of Woven Fabric Webbings for Inflatable Space Modules

    Get PDF
    eveloping technologies for proposed lunar and Mars space exploration missions. Enhanced habitation sy g studied as potential habitats due to their inherent low mass and small launch volume. One goal of inflatable module research is quantification of the safe-life and end-of-life creep-strain spectrum. Full-scale pressurized inflatable modules are large, costly, and difficult to experimentally study. Therefore, material subcomponents are often studied as an alternative. An experimental thermally controlled long-term creep study of VectranTM webbings for application to inflatable modules is presented. Vectran fibers have high strength and low creep properties. High strength webbing materials are desirable for the load bearing restraint layer of inflatable modules because they are strong, flexible, and lightweight. Characterization of the creep behavior, safe-life, and end-of- life of webbing specimens will help quantify comparable life properties for inflatable modules. Several experimental multiple-year creep studies of webbing specimens in uncontrolled thermal environments have been conducted at NASA Langley Research Center. Experimental data obtained exhibits the classic creep-strain curve due to load, coupled with unique sinusoidal variation due to variation in temperature and humidity over daily and annual time periods. Results also have indicated that specimens fail within a year if the applied load is greater than 50 percent of the rated load. The primary goal of this study is to eliminate thermal effects from the creep data for a group of webbing specimens, and to allow uncontrolled thermal effects to influence the creep data of a second group of webbing specimens. Comparison of both sets of data will define how temperature influences creep data. A unique creep test facility was fabricated to facilitate the generation and comparison of the two sets of data. The facility consists of five creep test stands with an integrated heating and cooling system, and four creep test stands exposed to external environmental or ambient conditions. The facility contains displacement, temperature, humidity, and load sensors. Test specimens consist of one- inch wide, 48-inch long Vectran webbings rated at 12,500 pounds-per-inch. Experimental thermally controlled creep-strain data has been generated for two groups of webbing specimens. Applied load for all test stands was above 9000 lbs and greater than 50 percent of the rated load. Temperatures varied between 58F and 83F for the four test stands exposed to ambient conditions. Associated creep data exhibited the classic creep- strain profiles. The temperature was set to 72F for the five test stands in the controlled temperature environment. Creep data for tests with temperature control also exhibited the classic strain profiles. Data indicated that if the load is greater n thermal effects do not manifest. Therefore, creep tests with loads less than 50 percent of the rated load are planned for in the near future

    Geometric, aerodynamic, and kinematic characteristics of two twin keel parawings during deployment

    Get PDF
    Flight test data on geometric, aerodynamic, and kinematic characteristics of two twin keel parawings during deploymen

    Descriptive Linear modeling of steady-state visual evoked response

    Get PDF
    A study is being conducted to explore use of the steady state visual-evoke electrocortical response as an indicator of cognitive task loading. Application of linear descriptive modeling to steady state Visual Evoked Response (VER) data is summarized. Two aspects of linear modeling are reviewed: (1) unwrapping the phase-shift portion of the frequency response, and (2) parsimonious characterization of task-loading effects in terms of changes in model parameters. Model-based phase unwrapping appears to be most reliable in applications, such as manual control, where theoretical models are available. Linear descriptive modeling of the VER has not yet been shown to provide consistent and readily interpretable results

    Analytical comparison of transient and steady state visual evoked cortical potentials

    Get PDF
    To better describe the linear-dynamic properties of the human visual-cortical response system, transient and steady state Visual Evoked Response Potentials (VERP) were observed. The stimulus presentation device provided both the evoking stimulus (flickering or pulsing lights) and a video task display. The steady state stimulus was modulated by a complex, ten frequency, sum-of-sines, wave. The transient VERP was the time-locked average of the EEG to a series of narrow light pulses (pulse width of 10 msec). The Fourier transform of the averaged pulses had properties that approximate band limited white noise, i.e., a flat spectrum over the frequency region spanned by the 10 summed sines. The Fourier transform of both the steady state and the transient evoked potentials resulted in transfer that are equivalent and therefore comparable. To investigate the effects of task loading on evoked potentials, a grammatical reasoning task was provided. Results support the relevancy of continued application of a systems engineering approach for describing neurosensory functioning

    The automatic gain-matching in the PIBETA CsI calorimeter

    Full text link
    Segmented electromagnetic calorimeters are used to determine both the total energy and direction (momentum components) of charged particles and photons. A trade off is involved in selecting the degree of segmentation of the calorimeter as the spatial and energy resolutions are affected differently. Increased number of individual detectors reduces accidental particle pile-up per detector but introduces complications related to ADC pedestals and pedestal variations, exacerbates the effects of electronic noise and ground loops, and requires summing and discrimination of multiple analog signals. Moreover, electromagnetic showers initiated by individual ionizing particles spread over several detectors. This complicates the precise gain-matching of the detector elements which requires an iterative procedure. The PIBETA calorimeter is a 240-module pure CsI non-magnetic detector optimized for detection of photons and electrons in the energy range 5-100 MeV. We present the computer-controlled, automatic, in situ gain-matching procedure that we developed and used routinely in several rare pion and muon decay experiments with the PIBETA detector.Comment: 28 pages, 13 postscript figures, LaTeX, submitted to Nucl. Instrum. Meth.

    Perspectives on the ‘silent period’ for emergent bilinguals in England

    Get PDF
    This paper draws together the research findings from two ethnographic studies (Drury, 2007; Bligh, 2011) as a means to problematize the ‘silent period’ as experienced by young bilingual learners in two English speaking early years settings in England. Most teachers and senior early years practitioners in England are monolingual English speakers. The children (regardless of their mother tongue) are taught through the medium of spoken and written English in and through all subject areas. Bilingual learning through the mother tongue is not only disregarded in most schools in England but is actively discouraged in some. Three emergent bilingual learners were re-examined as case studies. Suki and Adyta (Bligh, 2011) of Japanese and Punjabi decent and Nazma (Drury, 2007) of Kashmiri descent were observed whilst they each negotiated new ways of knowing within and through an English pre-school setting. Sociocultural insights into how these young children employ their silenced mother tongue to negotiate their learning creates a fuller and richer portrait of the emergent bilingual learner both in and outside of preschool. These collaborative research findings present the silent period as agentive (Drury, 2007) and as a crucial time for self-mediated learning (Bligh, 2011) within the early years community of practice

    From Bengali to English: sequential bilingualism of a second-generation British Bangladeshi

    Get PDF
    The paper discusses sequential language acquisition of the researcher's daughter Safa who transformed from a monolingual Bengali speaker to an almost monolingual English speaker in a few months after moving to the UK. Safa was born in Bangladesh and was a monolingual Bengali speaker until she was three years and nine months when the family moved to the UK. Unlike most research on sequential bilingualism, Safa's transition from Bengali to English went through a period of an invented language, which she developed and used for a few months. Safa then underwent language shift as Bengali became her passive language. Safa's loss of fluency in Bengali was mainly due to the absence of Bengali linguistic environment, because her family lived outside the community. Safa's mother's indifference to Bangladeshi ethnicity and her parents’ positive attitude towards Britishness meant that her decline in Bengali did not cause them much concern. Despite the lack of proficiency in Bengali, Safa still retains a strong ethnic Bangladeshi identity. Tabors and Snow’s four-stage developmental process of sequential second-language acquisition has been applied to find the similarities and differences in Safa's case, while language maintenance and shift theories have contributed to the analysis of the process of her language shift

    New waterboatmen records for Western Canada (Hemiptera: Corixidae)

    Get PDF
    Trichocorixa verticalis (Fieber) is reported for the first time from the mainland of British Columbia and the subspecific assignment is discussed. Based on specimens in the Spencer Entomological Museum, one provincial record and one territorial record are added to the recent checklist of Canadian Hemiptera

    Design, Commissioning and Performance of the PIBETA Detector at PSI

    Full text link
    We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two three-month beam periods in 1999/2000 with pi+ stopping rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5-150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.Comment: 117 pages, 48 Postscript figures, 5 tables, Elsevier LaTeX, submitted to Nucl. Instrum. Meth.
    corecore