97 research outputs found

    The Influence of Parasite Infections on Host Immunity to Co-Infection with Other Pathogens

    Get PDF
    Parasites have evolved a wide range of mechanisms that they use to evade or manipulate the host's immune response and establish infection. The majority of the in vivo studies that have investigated these host-parasite interactions have been undertaken in experimental animals, especially rodents, which were housed and maintained to a high microbiological status. However, in the field situation it is increasingly apparent that pathogen co-infections within the same host are a common occurrence. For example, chronic infection with pathogens including malarial parasites, soil-transmitted helminths, Mycobacterium tuberculosis and viruses such as HIV may affect a third of the human population of some developing countries. Increasing evidence shows that co-infection with these pathogens may alter susceptibility to other important pathogens, and/or influence vaccine efficacy through their effects on host immune responsiveness. Co-infection with certain pathogens may also hinder accurate disease diagnosis. This review summarizes our current understanding of how the host's immune response to infection with different types of parasites can influence susceptibility to infection with other pathogenic microorganisms. A greater understanding of how infectious disease susceptibility and pathogenesis can be influenced by parasite co-infections will enhance disease diagnosis and the design of novel vaccines or therapeutics to more effectively control the spread of infectious diseases

    Endurance et tenue diĂ©lectrique de l’isolation de cĂąbles Ă©lectriques pour l’aĂ©ronautique

    No full text
    In future "more electric" aircraft, the increase in on board electrical power will result in an increase in voltage. The voltages envisaged today are lower than 1000 V DC, but higher values can be considered in the medium to long term. It is therefore essential to study possible premature degradation of existing equipment induced by this rise in voltage. This thesis work, specifically on aeronautical cables, is a contribution to this goal. The examined cables, consisting of a multi-stranded core on which PTFE and PI layers are wound, have undergone various static and dynamic accelerated thermal aging, under humidity, without or with electrical stress. Aging has been carried out in some cases for more than 9000 hours. Partial discharges (DP) were studied on these cables in terms of the appearance voltage PDIV and RPDIV. These DPs can occur outside the cable but alsoinside (for higher voltages) in the air gaps between the insulation and the conductive strands. This location has been confirmed by an electrostatic model. The effect of aging was only found in the case of internal discharges, with in some cases a significant reduction in RPDIV values.Physicochemical analyses of the electrical insulation system were carried out as well as x-ray radiography. Chemical modifications of the interfaces of the insulation system occur during aging. For the most advanced aging (after 9000h under thermal stress at 240°C), these changes result in the formation of cavities where DP can then take place. Finally, electrostatic measurements of surface potential (decline and return after neutralization) have shown, well before the observation of cavities, an increase in conductivity of one of the layers of the insulation.Dans la perspective de l’aĂ©ronef « plus Ă©lectrique », l’augmentation de puissance Ă©lectrique embarquĂ©e se traduit par une augmentation de tension. Les tensions envisagĂ©es aujourd’hui sont infĂ©rieures Ă  1000 V DC. Mais des valeurs plus Ă©levĂ©es peuvent ĂȘtre considĂ©rĂ©es pour le futur. Il est donc indispensable d’étudier les dĂ©gradations prĂ©maturĂ©es induites par cette Ă©lĂ©vation de tension sur les Ă©quipements existants. Ce travail de thĂšse, portant spĂ©cifiquement sur les cĂąbles aĂ©ronautiques, constitue une contribution Ă  cette Ă©tude. Les cĂąbles examinĂ©s, constituĂ©s d’une Ăąme multibrins sur laquelle sont rubanĂ©es des couches de PTFE et PI, ont subi diffĂ©rents vieillissements accĂ©lĂ©rĂ©s thermiques statiques et dynamiques, sous humiditĂ©, et ce sans ou avec contrainte Ă©lectrique. Certains vieillissements ont Ă©tĂ© effectuĂ©s sur une durĂ©e supĂ©rieure Ă  9000 heures. Les dĂ©charges partielles (DP) ont Ă©tĂ© Ă©tudiĂ©es sur ces cĂąbles en termes de tension d’apparition PDIV et RPDIV. Ces DP peuvent intervenir Ă  l’extĂ©rieur ducĂąble mais Ă©galement Ă  l’intĂ©rieur (pour des tensions plus Ă©levĂ©es) dans les interstices d’air entre l’isolant et les brins conducteurs. Cette localisation a Ă©tĂ© confirmĂ©e par un modĂšle Ă©lectrostatique. L’effet du vieillissement n’a pu ĂȘtre constatĂ© que sur les dĂ©charges internes, avec dans certains cas une rĂ©duction significative des valeurs de RPDIV.Des analyses physicochimiques du systĂšme d’isolation Ă©lectrique ont Ă©tĂ© effectuĂ©es ainsi que des radiographies par rayons X. Des modifications chimiques des interfaces du systĂšme d’isolation interviennent au cours des vieillissements. Pour les vieillissements les plus poussĂ©s (aprĂšs 9000h sous contrainte thermique Ă  240°C), ces modifications rĂ©sultent en la formation de cavitĂ©s oĂč des DP peuvent prendre place. Enfin, des mesures Ă©lectrostatiques de potentiel de surface (dĂ©clin et retour aprĂšs neutralisation) ont mis en Ă©vidence, bien avant l’observation de cavitĂ©s, une augmentation de conductivitĂ© d’une des couches de l’isolation

    Endurance and dielectric strength of electrical cable insulation for aeronautics

    No full text
    Dans la perspective de l’aĂ©ronef « plus Ă©lectrique », l’augmentation de puissance Ă©lectrique embarquĂ©e se traduit par une augmentation de tension. Les tensions envisagĂ©es aujourd’hui sont infĂ©rieures Ă  1000 V DC. Mais des valeurs plus Ă©levĂ©es peuvent ĂȘtre considĂ©rĂ©es pour le futur. Il est donc indispensable d’étudier les dĂ©gradations prĂ©maturĂ©es induites par cette Ă©lĂ©vation de tension sur les Ă©quipements existants. Ce travail de thĂšse, portant spĂ©cifiquement sur les cĂąbles aĂ©ronautiques, constitue une contribution Ă  cette Ă©tude. Les cĂąbles examinĂ©s, constituĂ©s d’une Ăąme multibrins sur laquelle sont rubanĂ©es des couches de PTFE et PI, ont subi diffĂ©rents vieillissements accĂ©lĂ©rĂ©s thermiques statiques et dynamiques, sous humiditĂ©, et ce sans ou avec contrainte Ă©lectrique. Certains vieillissements ont Ă©tĂ© effectuĂ©s sur une durĂ©e supĂ©rieure Ă  9000 heures. Les dĂ©charges partielles (DP) ont Ă©tĂ© Ă©tudiĂ©es sur ces cĂąbles en termes de tension d’apparition PDIV et RPDIV. Ces DP peuvent intervenir Ă  l’extĂ©rieur ducĂąble mais Ă©galement Ă  l’intĂ©rieur (pour des tensions plus Ă©levĂ©es) dans les interstices d’air entre l’isolant et les brins conducteurs. Cette localisation a Ă©tĂ© confirmĂ©e par un modĂšle Ă©lectrostatique. L’effet du vieillissement n’a pu ĂȘtre constatĂ© que sur les dĂ©charges internes, avec dans certains cas une rĂ©duction significative des valeurs de RPDIV.Des analyses physicochimiques du systĂšme d’isolation Ă©lectrique ont Ă©tĂ© effectuĂ©es ainsi que des radiographies par rayons X. Des modifications chimiques des interfaces du systĂšme d’isolation interviennent au cours des vieillissements. Pour les vieillissements les plus poussĂ©s (aprĂšs 9000h sous contrainte thermique Ă  240°C), ces modifications rĂ©sultent en la formation de cavitĂ©s oĂč des DP peuvent prendre place. Enfin, des mesures Ă©lectrostatiques de potentiel de surface (dĂ©clin et retour aprĂšs neutralisation) ont mis en Ă©vidence, bien avant l’observation de cavitĂ©s, une augmentation de conductivitĂ© d’une des couches de l’isolation.In future "more electric" aircraft, the increase in on board electrical power will result in an increase in voltage. The voltages envisaged today are lower than 1000 V DC, but higher values can be considered in the medium to long term. It is therefore essential to study possible premature degradation of existing equipment induced by this rise in voltage. This thesis work, specifically on aeronautical cables, is a contribution to this goal. The examined cables, consisting of a multi-stranded core on which PTFE and PI layers are wound, have undergone various static and dynamic accelerated thermal aging, under humidity, without or with electrical stress. Aging has been carried out in some cases for more than 9000 hours. Partial discharges (DP) were studied on these cables in terms of the appearance voltage PDIV and RPDIV. These DPs can occur outside the cable but alsoinside (for higher voltages) in the air gaps between the insulation and the conductive strands. This location has been confirmed by an electrostatic model. The effect of aging was only found in the case of internal discharges, with in some cases a significant reduction in RPDIV values.Physicochemical analyses of the electrical insulation system were carried out as well as x-ray radiography. Chemical modifications of the interfaces of the insulation system occur during aging. For the most advanced aging (after 9000h under thermal stress at 240°C), these changes result in the formation of cavities where DP can then take place. Finally, electrostatic measurements of surface potential (decline and return after neutralization) have shown, well before the observation of cavities, an increase in conductivity of one of the layers of the insulation

    Pluri-infestations et contrainte parasitaire: aspects parasitologiques, immunologiques et anatomopathologiques dans le modĂšle souris/ Filaire-Plasmodium

    No full text
    Dans le cadre d’une interaction hĂŽte-parasite, des adaptations rĂ©ciproques sont misesen place par chacun des deux protagonistes, pour maximiser ou au contraire minimiser larĂ©ussite parasitaire. Le systĂšme immunitaire de l’hĂŽte joue un rĂŽle majeur dans cesmĂ©canismes de rĂ©gulation. Chez la souris Mus musculus, de nombreuses Ă©tudes ont Ă©tĂ©rĂ©alisĂ©es en laboratoire sur des mono-infestations expĂ©rimentales avec des parasites naturelsou non de la souris. Cependant, en conditions naturelles, un hĂŽte est souvent infestĂ© parplusieurs espĂšces de parasites. Des Ă©tudes expĂ©rimentales de multi-infestations reflĂšteraientainsi mieux les conditions naturelles des interactions. Dans ce travail, nous avons rĂ©alisĂ© desco-infestations contrĂŽlĂ©es et simultanĂ©es d'une lignĂ©e consanguine de souris avec deuxespĂšces de parasites : la filaire Litomosoides sigmodontis et l'apicomplexe Plasmodium spp.Du fait de la disponibilitĂ© d'un grand nombre de souches de Plasmodium dans les collectionsdu MusĂ©um National d'Histoire Naturelle, la premiĂšre Ă©tape de cette Ă©tude a Ă©tĂ© desĂ©lectionner des souches non lĂ©tales de Plasmodium prĂ©sentant un seul pic de parasitĂ©mie.Nous avons retenu P. yoelii yoelii clone 1.1 dans une premiĂšre Ă©tude oĂč des paramĂštres de larĂ©ponse immunitaire ont Ă©tĂ© Ă©tudiĂ©s, et P. chabaudi chabaudi 864VD dans une deuxiĂšmeĂ©tude oĂč une analyse prĂ©liminaire des lĂ©sions anatomopathologiques a Ă©tĂ© effectuĂ©e. LesparamĂštres immunologiques et phĂ©notypiques pris en compte mettent en Ă©vidence desdiffĂ©rences entre les mono- et les co-infestations. En situation de co-infection, nous montronsque les deux parasites sont capables de se dĂ©velopper en prĂ©sence l'un de l'autre, mais chacuna un effet limitant sur l'autre; le pic de parasitĂ©mie plasmodial est plus bas et la chargefilarienne rĂ©duite en situation de co-infection. Cette modification phĂ©notypique est Ă  associeravec des diffĂ©rences immunitaires aussi bien dans la voie Th2 (rĂ©ponse IL-5 prĂ©pondĂ©rantedans l'infection filarienne, absente en co-infection) que dans la rĂ©gulation immunitaire (l'IL-10mesurĂ©e dans l'infection plasmodiale est immunorĂ©gulĂ©e par la prĂ©sence concomitante de lafilaire). La co-infection n'a cependant pas d'effet sur la splĂ©nomĂ©galie induite parPlasmodium, et ceci quelle que soit la souche de Plasmodium utilisĂ©e. Enfin la caractĂ©risationdes lĂ©sions par une Ă©tude anatomopathologique pourrait contribuer Ă  mieux dĂ©finir lesdiffĂ©rentes souches de Plasmodium de rongeurs et aider Ă  discriminer l'impact de l'infectionfilarienne sur les lĂ©sions dues Ă  l'infection plasmodiale.L’intĂ©rĂȘt en immunologie et en anatomopathologie de ce modĂšle de pluri-infestation chez lasouris consanguine est donc confirmĂ© par cette Ă©tude prĂ©liminaire

    A lesion on the tip of the tongue

    No full text

    La place de l'aéromathérapie à l'officine

    No full text
    CHATENAY M.-PARIS 11-BU Pharma. (920192101) / SudocSudocFranceF

    Systematic revision of the adeleid haemogregarines, with creation of

    No full text
    Life cycles and molecular data for terrestrial haemogregarines are reviewed in this article. Collection material was re-examined: Hepatozoon argantis Garnham, 1954 in Argas brumpti was reassigned to Hemolivia as Hemolivia argantis (Garnham, 1954) n. comb.; parasite DNA was extracted from a tick crush on smear of an archived slide of Hemolivia stellata in Amblyomma rotondatum, then the 18S ssrRNA gene was amplified by PCR. A systematic revision of the group is proposed, based on biological life cycles and phylogenetic reconstruction. Four types of life cycles, based on parasite vector, vertebrate host and the characteristics of their development, are defined. We propose combining species, based on their biology, into four groups (types I, II, III and IV). The characters of each type are defined and associated with a type genus and a type species. The biological characters of each type are associated with a different genus and a type species. The phylogenetic reconstruction with sequences deposited in the databases and our own new sequence of Hemolivia stellata is consistent with this classification. The classification is as follows: Type I, Hepatozoon Miller, 1908, type species H. perniciosum Miller, 1908; Type II, Karyolysus Labbé, 1894, type species K. lacertae (Danilewsky, 1886) Reichenow, 1913; Type III Hemolivia Petit et al., 1990, type species H. stellata, Petit et al., 1990; and Type IV: Bartazoon n. g., type species B. breinli (Mackerras, 1960)
    • 

    corecore