22 research outputs found

    New Medical Device and Therapeutic Approvals in Otolaryngology: State of the Art Review of 2021

    Get PDF
    Objective To evaluate new medical devices and drugs pertinent to otolaryngology-head and neck surgery that were approved by the Food and Drug Administration (FDA) in 2021.Data SourcesPublicly available FDA device and drug approvals from ENT (ear, nose, and throat), anesthesia, neurosurgery, plastic surgery, and general surgery FDA committees. Review Methods FDA device and therapeutic approvals were identified and reviewed by members of the American Academy of Otolaryngology-Head and Neck Surgery's Medical Devices and Drugs Committee. Two independent reviewers assessed the relevance of devices and drugs to otolaryngologists. Medical devices and drugs were then allocated to their respective subspecialty fields for critical review based on available scientific literature. Conclusions The Medical Devices and Drugs Committee reviewed 1153 devices and 52 novel drugs that received FDA approval in 2021 (67 ENT, 106 anesthesia, 618 general surgery and plastic surgery, 362 neurosurgery). Twenty-three devices and 1 therapeutic agent relevant to otolaryngology were included in the state of the art review. Advances spanned all subspecialties, including over-the-counter hearing aid options in otology, expanding treatment options for rhinitis in rhinology, innovative laser-safe endotracheal tubes in laryngology, novel facial rejuvenation and implant technology in facial plastic surgery, and advances in noninvasive and surgical treatment options for obstructive sleep apnea. Implications for Practice FDA approvals for new technology and pharmaceuticals present new opportunities across subspecialties in otolaryngology. Clinicians? nuanced understanding of the safety, advantages, and limitations of these innovations ensures ongoing progress in patient care

    Measurement of the muon flux from 400 GeV/c protons interacting in a thick molybdenum/tungsten target

    Get PDF
    The SHiP experiment is proposed to search for very weakly interacting particles beyond the Standard Model which are produced in a 400 GeV/c proton beam dump at the CERN SPS. About 1011 muons per spill will be produced in the dump. To design the experiment such that the muon-induced background is minimized, a precise knowledge of the muon spectrum is required. To validate the muon flux generated by our Pythia and GEANT4 based Monte Carlo simulation (FairShip), we have measured the muon flux emanating from a SHiP-like target at the SPS. This target, consisting of 13 interaction lengths of slabs of molybdenum and tungsten, followed by a 2.4 m iron hadron absorber was placed in the H4 400 GeV/c proton beam line. To identify muons and to measure the momentum spectrum, a spectrometer instrumented with drift tubes and a muon tagger were used. During a 3-week period a dataset for analysis corresponding to (3.27±0.07) × 1011 protons on target was recorded. This amounts to approximatively 1% of a SHiP spill

    Track reconstruction and matching between emulsion and silicon pixel detectors for the SHiP-charm experiment

    Get PDF
    In July 2018 an optimization run for the proposed charm cross section measurement for SHiP was performed at the CERN SPS. A heavy, moving target instrumented with nuclear emulsion films followed by a silicon pixel tracker was installed in front of the Goliath magnet at the H4 proton beam-line. Behind the magnet, scintillating-fibre, drift-tube and RPC detectors were placed. The purpose of this run was to validate the measurement's feasibility, to develop the required analysis tools and fine-tune the detector layout. In this paper, we present the track reconstruction in the pixel tracker and the track matching with the moving emulsion detector. The pixel detector performed as expected and it is shown that, after proper alignment, a vertex matching rate of 87% is achieved

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Reconstructing the fractal clusters of detonation nanodiamonds from small-angle X-ray scattering

    No full text
    Detonation nanodiamonds (DND) form fractal-like aggregates composed of polydisperse DND particles. We present a novel methodology for the visualisation and characterisation of fractal clusters of DND from one-dimensional small-angle X-ray scattering (SAXS) intensity. The fractal nature and polydispersity of DND are modelled by combining a diffusion-limited aggregation (DLA) process implemented in Monte Carlo simulations with the distribution of DND sizes measured from high-resolution transmission electron microscopy. The radius of gyration (42–44 nm), aggregation number (850–1150), and the maximum dimension (226–242 nm) of DND fractal clusters were obtained from the fitting of the synchrotron-based SAXS data (q∌0.11–4.75 1/nm) measured for two samples of commercialized DND powders by the developed theoretical model

    The Accuracy of Owner-Provided House Values: The 1978-1991 American Housing Survey

    No full text
    The American Housing Survey (AHS) includes the owner's valuation of the house as a measure of the house's value. If owner-stated values are accurate, the AHS (as well as other survey instruments) can be used by researchers studying a variety of topics. In this study we use the metropolitan version of the AHS for three cities over fourteen years to compare owners' valuations with sales prices of houses that sold in the twelve months prior to an interview. We find that, on average, recent buyers report house values that are 8.4% higher than the stated sales prices. Further analysis indicates that these recent buyers, when compared with owners with longer tenure, overvalue their houses by 3.3%, on average. Thus, we find that the average owner overvalues his house by 5.1%. Also, differences between sales prices and owners' valuations are not related to particular characteristics of the house, occupants (other than length of tenure), or neighborhood. Thus, the use of the owners' valuations will result in accurate estimates of house price indexes and will provide reliable estimates of the prices of house and neighborhood characteristics. Copyright American Real Estate and Urban Economics Association.
    corecore