41 research outputs found

    Accuracy of Continuous Glucose Monitoring During Three Closed-Loop Home Studies Under Free-Living Conditions.

    Get PDF
    OBJECTIVES: Closed-loop (CL) systems modulate insulin delivery based on glucose levels measured by a continuous glucose monitor (CGM). Accuracy of the CGM affects CL performance and safety. We evaluated the accuracy of the Freestyle Navigator(®) II CGM (Abbott Diabetes Care, Alameda, CA) during three unsupervised, randomized, open-label, crossover home CL studies. MATERIALS AND METHODS: Paired CGM and capillary glucose values (10,597 pairs) were collected from 57 participants with type 1 diabetes (41 adults [mean±SD age, 39±12 years; mean±SD hemoglobin A1c, 7.9±0.8%] recruited at five centers and 16 adolescents [mean±SD age, 15.6±3.6 years; mean±SD hemoglobin A1c, 8.1±0.8%] recruited at two centers). Numerical accuracy was assessed by absolute relative difference (ARD) and International Organization for Standardization (ISO) 15197:2013 15/15% limits, and clinical accuracy was assessed by Clarke error grid analysis. RESULTS: Total duration of sensor use was 2,002 days (48,052 h). Overall sensor accuracy for the capillary glucose range (1.1-27.8 mmol/L) showed mean±SD and median (interquartile range) ARD of 14.2±15.5% and 10.0% (4.5%, 18.4%), respectively. Lowest mean ARD was observed in the hyperglycemic range (9.8±8.8%). Over 95% of pairs were in combined Clarke error grid Zones A and B (A, 80.1%, B, 16.2%). Overall, 70.0% of the sensor readings satisfied ISO criteria. Mean ARD was consistent (12.3%; 95% of the values fall within ±3.7%) and not different between participants (P=0.06) within the euglycemic and hyperglycemic range, when CL is actively modulating insulin delivery. CONCLUSIONS: Consistent accuracy of the CGM within the euglycemic-hyperglycemic range using the Freestyle Navigator II was observed and supports its use in home CL studies. Our results may contribute toward establishing normative CGM performance criteria for unsupervised home use of CL.Juvenile Diabetes Research Foundation (#22-2009-802), Diabetes UK (BDA07/0003549) and Seventh Framework Programme of the European Union (Grant Agreement number 247138) with additional support for the Artificial Pancreas work by National Institute of Diabetes and Digestive and Kidney Diseases (1R01DK085621), Wellcome Strategic Award (100574/Z/12/Z), and National Institute for Health Research Cambridge Biomedical Research Centre.This is the final version of the article. It first appeared from Mary Ann Liebert via http://dx.doi.org/10.1089/dia.2015.006

    Weaning practices in phenylketonuria vary between health professionals in Europe

    Get PDF
    Background: In phenylketonuria (PKU), weaning is considered more challenging when compared to feeding healthy infants. The primary aim of weaning is to gradually replace natural protein from breast milk or standard infant formula with solids containing equivalent phenylalanine (Phe). In addition, a Phe-free second stage L-amino acid supplement is usually recommended from around 6 months to replace Phe-free infant formula. Our aim was to assess different weaning approaches used by health professionals across Europe. Methods: A cross sectional questionnaire (survey monkey (R)) composed of 31 multiple and single choice questions was sent to European colleagues caring for inherited metabolic disorders (IMD). Centres were grouped into geographical regions for analysis. Results: Weaning started at 17-26 weeks in 85% (n=81/95) of centres, > 26 weeks in 12% (n=11/95) and 26 weeks. First solids were mainly low Phe vegetables (59%, n=56/95) and fruit (34%, n=32/95). A Phe exchange system to allocate dietary Phe was used by 52% (n=49/95) of centres predominantly from Northern and Southern Europe and 48% (n=46/95) calculated most Phe containing food sources (all centres in Eastern Europe and the majority from Germany and Austria). Some centres used a combination of both methods. A second stage Phe-free L-amino acid supplement containing a higher protein equivalent was introduced by 41% (n=39/95) of centres at infant age 26-36 weeks (mainly from Germany, Austria, Northern and Eastern Europe) and 37% (n=35/95) at infant age > 1y mainly from Southern Europe. 53% (n=50/95) of centres recommended a second stage Phe-free L-amino acid supplement in a spoonable or semi-solid form. Conclusions: Weaning strategies vary throughout European PKU centres. There is evidence to suggest that different infant weaning strategies may influence longer term adherence to the PKU diet or acceptance of Phe-free L-amino acid supplements; rendering prospective long-term studies important. It is essential to identify an effective weaning strategy that reduces caregiver burden but is associated with acceptable dietary adherence and optimal infant feeding development.Peer reviewe

    Early feeding practices in infants with phenylketonuria across Europe

    Get PDF
    Background: In infants with phenylketonuria (PKU), dietary management is based on lowering and titrating phenylalanine (Phe) intake from breast milk or standard infant formula in combination with a Phe-free infant formula in order to maintain blood Phe levels within target range. Professionals use different methods to feed infants with PKU and our survey aimed to document practices across Europe. Methods: We sent a cross sectional, survey monkey (R) questionnaire to European health professionals working in IMD. It contained 31 open and multiple-choice questions. The results were analysed according to different geographical regions. Results: Ninety-five centres from 21 countries responded. Over 60% of centres commenced diet in infants by age 10 days, with 58% of centres implementing newborn screening by day 3 post birth. At diagnosis, infant hospital admission occurred in 61% of metabolic centres, mainly in Eastern, Western and Southern Europe. Breastfeeding fell sharply following diagnosis with only 30% of women still breast feeding at 6 months. 53% of centres gave pre-measured Phe-free infant formula before each breast feed and 23% alternated breast feeds with Phe-free infant formula. With standard infant formula feeds, measured amounts were followed by Phe-free infant formula to satiety in 37% of centres (n = 35/95), whereas 44% (n = 42/95) advised mixing both formulas together. Weaning commenced between 17 and 26 weeks in 85% centres, >= 26 weeks in 12% and <17 weeks in 3%. Discussion: This is the largest European survey completed on PKU infant feeding practices. It is evident that practices varied widely across Europe, and the practicalities of infant feeding in PKU received little focus in the PKU European Guidelines (2017). There are few reports comparing different feeding techniques with blood Phe control, Phe fluctuations and growth. Controlled prospective studies are necessary to assess how different infant feeding practices may influence longer term feeding development.Peer reviewe

    Deleterious ABCA7 mutations and transcript rescue mechanisms in early onset Alzheimer’s disease

    Get PDF
    Abstract: Premature termination codon (PTC) mutations in the ATP-Binding Cassette, Sub-Family A, Member 7 gene (ABCA7) have recently been identified as intermediate-to-high penetrant risk factor for late-onset Alzheimer's disease (LOAD). High variability, however, is observed in downstream ABCA7 mRNA and protein expression, disease penetrance, and onset age, indicative of unknown modifying factors. Here, we investigated the prevalence and disease penetrance of ABCA7 PTC mutations in a large early onset AD (EOAD)-control cohort, and examined the effect on transcript level with comprehensive third-generation long-read sequencing. We characterized the ABCA7 coding sequence with next-generation sequencing in 928 EOAD patients and 980 matched control individuals. With MetaSKAT rare variant association analysis, we observed a fivefold enrichment (p = 0.0004) of PTC mutations in EOAD patients (3%) versus controls (0.6%). Ten novel PTC mutations were only observed in patients, and PTC mutation carriers in general had an increased familial AD load. In addition, we observed nominal risk reducing trends for three common coding variants. Seven PTC mutations were further analyzed using targeted long-read cDNA sequencing on an Oxford Nanopore MinION platform. PTC-containing transcripts for each investigated PTC mutation were observed at varying proportion (5-41% of the total read count), implying incomplete nonsense-mediated mRNA decay (NMD). Furthermore, we distinguished and phased several previously unknown alternative splicing events (up to 30% of transcripts). In conjunction with PTC mutations, several of these novel ABCA7 isoforms have the potential to rescue deleterious PTC effects. In conclusion, ABCA7 PTC mutations play a substantial role in EOAD, warranting genetic screening of ABCA7 in genetically unexplained patients. Long-read cDNA sequencing revealed both varying degrees of NMD and transcript-modifying events, which may influence ABCA7 dosage, disease severity, and may create opportunities for therapeutic interventions in AD

    Continuous glucose monitoring in pregnant women with type 1 diabetes (CONCEPTT): a multicentre international randomised controlled trial.

    Get PDF
    BACKGROUND: Pregnant women with type 1 diabetes are a high-risk population who are recommended to strive for optimal glucose control, but neonatal outcomes attributed to maternal hyperglycaemia remain suboptimal. Our aim was to examine the effectiveness of continuous glucose monitoring (CGM) on maternal glucose control and obstetric and neonatal health outcomes. METHODS: In this multicentre, open-label, randomised controlled trial, we recruited women aged 18-40 years with type 1 diabetes for a minimum of 12 months who were receiving intensive insulin therapy. Participants were pregnant (≤13 weeks and 6 days' gestation) or planning pregnancy from 31 hospitals in Canada, England, Scotland, Spain, Italy, Ireland, and the USA. We ran two trials in parallel for pregnant participants and for participants planning pregnancy. In both trials, participants were randomly assigned to either CGM in addition to capillary glucose monitoring or capillary glucose monitoring alone. Randomisation was stratified by insulin delivery (pump or injections) and baseline glycated haemoglobin (HbA1c). The primary outcome was change in HbA1c from randomisation to 34 weeks' gestation in pregnant women and to 24 weeks or conception in women planning pregnancy, and was assessed in all randomised participants with baseline assessments. Secondary outcomes included obstetric and neonatal health outcomes, assessed with all available data without imputation. This trial is registered with ClinicalTrials.gov, number NCT01788527. FINDINGS: Between March 25, 2013, and March 22, 2016, we randomly assigned 325 women (215 pregnant, 110 planning pregnancy) to capillary glucose monitoring with CGM (108 pregnant and 53 planning pregnancy) or without (107 pregnant and 57 planning pregnancy). We found a small difference in HbA1c in pregnant women using CGM (mean difference -0·19%; 95% CI -0·34 to -0·03; p=0·0207). Pregnant CGM users spent more time in target (68% vs 61%; p=0·0034) and less time hyperglycaemic (27% vs 32%; p=0·0279) than did pregnant control participants, with comparable severe hypoglycaemia episodes (18 CGM and 21 control) and time spent hypoglycaemic (3% vs 4%; p=0·10). Neonatal health outcomes were significantly improved, with lower incidence of large for gestational age (odds ratio 0·51, 95% CI 0·28 to 0·90; p=0·0210), fewer neonatal intensive care admissions lasting more than 24 h (0·48; 0·26 to 0·86; p=0·0157), fewer incidences of neonatal hypoglycaemia (0·45; 0·22 to 0·89; p=0·0250), and 1-day shorter length of hospital stay (p=0·0091). We found no apparent benefit of CGM in women planning pregnancy. Adverse events occurred in 51 (48%) of CGM participants and 43 (40%) of control participants in the pregnancy trial, and in 12 (27%) of CGM participants and 21 (37%) of control participants in the planning pregnancy trial. Serious adverse events occurred in 13 (6%) participants in the pregnancy trial (eight [7%] CGM, five [5%] control) and in three (3%) participants in the planning pregnancy trial (two [4%] CGM and one [2%] control). The most common adverse events were skin reactions occurring in 49 (48%) of 103 CGM participants and eight (8%) of 104 control participants during pregnancy and in 23 (44%) of 52 CGM participants and five (9%) of 57 control participants in the planning pregnancy trial. The most common serious adverse events were gastrointestinal (nausea and vomiting in four participants during pregnancy and three participants planning pregnancy). INTERPRETATION: Use of CGM during pregnancy in patients with type 1 diabetes is associated with improved neonatal outcomes, which are likely to be attributed to reduced exposure to maternal hyperglycaemia. CGM should be offered to all pregnant women with type 1 diabetes using intensive insulin therapy. This study is the first to indicate potential for improvements in non-glycaemic health outcomes from CGM use. FUNDING: Juvenile Diabetes Research Foundation, Canadian Clinical Trials Network, and National Institute for Health Research
    corecore