1,079 research outputs found

    Molybdenum back-contact optimization for CIGS thin film solar cell

    Get PDF
    Molybdenum (Mo) thin films are most widely used as an ohmic back-contact in the copper indium diselenide (CIS) and its alloy copper indium gallium diselenide (CIGS) based thin film solar cell. Radio frequency (RF) magnetron sputtering system used to deposit Mo thin films on soda lime glass substrate. The deposition was carried out using argon (Ar) gas at different Ar controlled (working) pressures (1 mTorr to 10 mTorr) and at different RF powers (60 W to 100 W). The influence of both the working pressure and the RF power on the Mo thin films was studied by investigating its structural, morphological, electrical, and optical measurements. The results reveal that a stress-free, low-sheet-resistance (~1 W/), and reflecting (~ 55 %) Mo thin film was observed at 1 mTorr working pressure and 100 W RF power. When you are citing the document, use the following link http://essuir.sumdu.edu.ua/handle/123456789/2211

    MATHEMATICAL MODELLING FOR MAGNETITE (CRUDE) REMOVAL FROM PRIMARY HEAT TRANSFER LOOP BY ION-EXCHANGE RESINS

    Get PDF
    The present research focuses to develop mathematical model for the removal of iron (magnetite) by ion-exchange resin from primary heat transfer loop of process industries. This mathematical model is based on operating capacities (that's provide more effective design as compared to loading capacity) from static laboratory tests. Results showed non-steady state distribution of external Fe2+ and limitations imposed on operating conditions, these conditions includes; loading and elution cycle time, flow rate, concentration of both loading and removal, volume of resin required. Number of generalized assumptions was made under shortcut modeling techniques to overcome the gap of theoretical and actual process design. KEY WORDS: Magnetite, Mathematical modeling, Ion-exchange resin, Operating capacity, Loading capacity Bull. Chem. Soc. Ethiop. 2009, 23(1), 129-133

    Energy relaxation of an excited electron gas in quantum wires: many-body electron LO-phonon coupling

    Full text link
    We theoretically study energy relaxation via LO-phonon emission in an excited one-dimensional electron gas confined in a GaAs quantum wire structure. We find that the inclusion of phonon renormalization effects in the theory extends the LO-phonon dominated loss regime down to substantially lower temperatures. We show that a simple plasmon-pole approximation works well for this problem, and discuss implications of our results for low temperature electron heating experiments in quantum wires.Comment: 10 pages, RevTex, 4 figures included. Also available at http://www-cmg.physics.umd.edu/~lzheng

    Application of the scattering rate sum-rule to the interplane optical conductivity of high temperature superconductors: pseudogap and bi-layer effects

    Full text link
    We use a recently proposed model of the interplane conductivity of high temperature superconductors to investigate the `scattering rate sum-rule' introduced by Basov and co-workers. We present a new derivation of the sum-rule. The quantal and thermal fluctuations of the order parameter which have been argued to produce the observed pseudogap behavior are shown to increase the total integrated `scattering rate' but may either increase or decrease the `quasiparticle' contribution from frequencies greater than twice the superconducting gap.Comment: 4 pages, 5 figures, revise

    The Asymptotic distribution of circles in the orbits of Kleinian groups

    Full text link
    Let P be a locally finite circle packing in the plane invariant under a non-elementary Kleinian group Gamma and with finitely many Gamma-orbits. When Gamma is geometrically finite, we construct an explicit Borel measure on the plane which describes the asymptotic distribution of small circles in P, assuming that either the critical exponent of Gamma is strictly bigger than 1 or P does not contain an infinite bouquet of tangent circles glued at a parabolic fixed point of Gamma. Our construction also works for P invariant under a geometrically infinite group Gamma, provided Gamma admits a finite Bowen-Margulis-Sullivan measure and the Gamma-skinning size of P is finite. Some concrete circle packings to which our result applies include Apollonian circle packings, Sierpinski curves, Schottky dances, etc.Comment: 31 pages, 8 figures. Final version. To appear in Inventiones Mat

    Use of Coronary Computed Tomographic Angiography to guide management of patients with coronary disease

    Get PDF
    Background In a prospective, multicenter, randomized controlled trial, 4,146 patients were randomized to receive standard care or standard care plus coronary computed tomography angiography (CCTA). Objectives The purpose of this study was to explore the consequences of CCTA-assisted diagnosis on invasive coronary angiography, preventive treatments, and clinical outcomes. Methods In post hoc analyses, we assessed changes in invasive coronary angiography, preventive treatments, and clinical outcomes using national electronic health records. Results Despite similar overall rates (409 vs. 401; p = 0.451), invasive angiography was less likely to demonstrate normal coronary arteries (20 vs. 56; hazard ratios [HRs]: 0.39 [95% confidence interval (CI): 0.23 to 0.68]; p < 0.001) but more likely to show obstructive coronary artery disease (283 vs. 230; HR: 1.29 [95% CI: 1.08 to 1.55]; p = 0.005) in those allocated to CCTA. More preventive therapies (283 vs. 74; HR: 4.03 [95% CI: 3.12 to 5.20]; p < 0.001) were initiated after CCTA, with each drug commencing at a median of 48 to 52 days after clinic attendance. From the median time for preventive therapy initiation (50 days), fatal and nonfatal myocardial infarction was halved in patients allocated to CCTA compared with those assigned to standard care (17 vs. 34; HR: 0.50 [95% CI: 0.28 to 0.88]; p = 0.020). Cumulative 6-month costs were slightly higher with CCTA: difference 462(95462 (95% CI: 303 to $621). Conclusions In patients with suspected angina due to coronary heart disease, CCTA leads to more appropriate use of invasive angiography and alterations in preventive therapies that were associated with a halving of fatal and non-fatal myocardial infarction. (Scottish COmputed Tomography of the HEART Trial [SCOT-HEART]; NCT01149590

    ProLuCID: An improved SEQUEST-like algorithm with enhanced sensitivity and specificity

    Get PDF
    AbstractProLuCID, a new algorithm for peptide identification using tandem mass spectrometry and protein sequence databases has been developed. This algorithm uses a three tier scoring scheme. First, a binomial probability is used as a preliminary scoring scheme to select candidate peptides. The binomial probability scores generated by ProLuCID minimize molecular weight bias and are independent of database size. A modified cross-correlation score is calculated for each candidate peptide identified by the binomial probability. This cross-correlation scoring function models the isotopic distributions of fragment ions of candidate peptides which ultimately results in higher sensitivity and specificity than that obtained with the SEQUEST XCorr. Finally, ProLuCID uses the distribution of XCorr values for all of the selected candidate peptides to compute a Z score for the peptide hit with the highest XCorr. The ProLuCID Z score combines the discriminative power of XCorr and DeltaCN, the standard parameters for assessing the quality of the peptide identification using SEQUEST, and displays significant improvement in specificity over ProLuCID XCorr alone. ProLuCID is also able to take advantage of high resolution MS/MS spectra leading to further improvements in specificity when compared to low resolution tandem MS data. A comparison of filtered data searched with SEQUEST and ProLuCID using the same false discovery rate as estimated by a target-decoy database strategy, shows that ProLuCID was able to identify as many as 25% more proteins than SEQUEST. ProLuCID is implemented in Java and can be easily installed on a single computer or a computer cluster.This article is part of a Special Issue entitled: Computational Proteomics

    Coronary CT Angiography and 5-Year Risk of Myocardial Infarction.

    Get PDF
    BACKGROUND: Although coronary computed tomographic angiography (CTA) improves diagnostic certainty in the assessment of patients with stable chest pain, its effect on 5-year clinical outcomes is unknown. METHODS: In an open-label, multicenter, parallel-group trial, we randomly assigned 4146 patients with stable chest pain who had been referred to a cardiology clinic for evaluation to standard care plus CTA (2073 patients) or to standard care alone (2073 patients). Investigations, treatments, and clinical outcomes were assessed over 3 to 7 years of follow-up. The primary end point was death from coronary heart disease or nonfatal myocardial infarction at 5 years. RESULTS: The median duration of follow-up was 4.8 years, which yielded 20,254 patient-years of follow-up. The 5-year rate of the primary end point was lower in the CTA group than in the standard-care group (2.3% [48 patients] vs. 3.9% [81 patients]; hazard ratio, 0.59; 95% confidence interval [CI], 0.41 to 0.84; P=0.004). Although the rates of invasive coronary angiography and coronary revascularization were higher in the CTA group than in the standard-care group in the first few months of follow-up, overall rates were similar at 5 years: invasive coronary angiography was performed in 491 patients in the CTA group and in 502 patients in the standard-care group (hazard ratio, 1.00; 95% CI, 0.88 to 1.13), and coronary revascularization was performed in 279 patients in the CTA group and in 267 in the standard-care group (hazard ratio, 1.07; 95% CI, 0.91 to 1.27). However, more preventive therapies were initiated in patients in the CTA group (odds ratio, 1.40; 95% CI, 1.19 to 1.65), as were more antianginal therapies (odds ratio, 1.27; 95% CI, 1.05 to 1.54). There were no significant between-group differences in the rates of cardiovascular or noncardiovascular deaths or deaths from any cause. CONCLUSIONS: In this trial, the use of CTA in addition to standard care in patients with stable chest pain resulted in a significantly lower rate of death from coronary heart disease or nonfatal myocardial infarction at 5 years than standard care alone, without resulting in a significantly higher rate of coronary angiography or coronary revascularization. (Funded by the Scottish Government Chief Scientist Office and others; SCOT-HEART ClinicalTrials.gov number, NCT01149590 .)

    Responsiveness and minimal important change of the Family Reported Outcome Measure (FROM-16)

    Get PDF
    Background: The FROM-16 is a generic family quality of life (QoL) instrument that measures the QoL impact of patients’ disease on their family members/partners. The study aimed to assess the responsiveness of FROM-16 to change and determine Minimal Important Change (MIC). Methods: Responsiveness and MIC for FROM-16 were assessed prospectively with patients and their family members recruited from outpatient departments of the University Hospital Wales and University Hospital Llandough, Cardiff, United Kingdom. Patients completed the EQ-5D-3L and a global severity question (GSQ) online at baseline and at 3-month follow-up. Family members completed FROM-16 at baseline and a Global Rating of Change (GRC) in addition to FROM-16 at follow-up. Responsiveness was assessed using the distribution-based (effect size-ES, standardized response mean -SRM) and anchor-based (area under the receiver operating characteristics curve ROC-AUC) approaches and by testing hypotheses on expected correlation strength between FROM-16 change score and patient assessment tools (GSQ and EQ-5D). Cohen’s criteria were used for assessing ES. The AUC ≥ 0.7 was considered a good measure of responsiveness. MIC was calculated using anchor-based (ROC analysis and adjusted predictive modelling) and distribution methods based on standard deviation (SD) and standard error of the measurement (SEM). Results: Eighty-three patients with 15 different health conditions and their relatives completed baseline and follow-up questionnaires and were included in the responsiveness analysis. The mean FROM-16 change over 3 months = 1.43 (SD = 4.98). The mean patient EQ-5D change over 3 months = −0.059 (SD = 0.14). The responsiveness analysis showed that the FROM-16 was responsive to change (ES = 0.2, SRM = 0.3; p < 0.01). The ES and SRM of FROM-16 change score ranged from small (ES = 0.2; SRM = 0.3) for the distribution-based method to large (ES = 0.8, SRM = 0.85) for anchor-based methods. The AUC value was above 0.7, indicating good responsiveness. There was a significant positive correlation between the FROM-16 change scores and the patient’s disease severity change scores (p < 0.001). The MIC analysis was based on data from 100 family members of 100 patients. The MIC value of 4 was suggested for FROM-16. Conclusions: The results of this study confirm the longitudinal validity of FROM-16 which refers to the degree to which an instrument is able to measure change in the construct to be measured. The results yield a MIC value of 4 for FROM-16. These psychometric attributes of the FROM-16 instrument are useful in both clinical research as well as clinical practice
    corecore