35 research outputs found

    Geant4 simulation of the response of phosphor screens for X-ray imaging

    Get PDF
    poster Pistrui-Maximean, submitted to NIM AIn order to predict and optimize the response of phosphor screens, it is important to understand the role played by the different physical processes inside the scintillator layer. Monte Carlo simulations were carried out to determine the Modulation Transfer Function (MTF) of phosphor screens for energies used in X-ray medical imaging and nondestructive testing applications. The visualization of the dose distribution inside the phosphor layer gives an insight into how the MTF is progressively degraded by X-ray and electron transport. The simulation model allows to study the influence of physical and technological parameters on the detector performances, as well as to design and optimize new detector configurations. Preliminary MTF measurements have been carried out and agreement with experimental data has been found in the case of a commercial screen (Kodak Lanex Fine), at an X-ray tube potential voltage of 100 kV. Further validation with other screens (transparent or granular) at different energies is under way

    Joint Simulation of Transmission X-ray Imaging on GPU and Patient's Respiration on CPU

    Get PDF
    Purpose: We previously proposed to compute the X-ray attenuation from polygons directly on the GPU, using OpenGL, to significantly increase performance without loss of accuracy. The method has been deployed into a training simulator for percutaneous transhepatic cholangiography. The simulations were however restricted to monochromatic X-rays using a point source. They now take into account both the geometrical blur and polychromatic X-rays. Method and Materials: To implement the Beer-Lambert law with a polychromatic beam, additional loops have been included in the simulation pipeline. It is split into rendering passes and uses frame buffer objects to store intermediate results. The source shape is modeled using a variable number of point sources and the incident beam is split into discrete energy channels. The respiration model is composed of ribs, spine, lungs, liver, diaphragm and the external skin. The organ motion simulation is based on anatomical and physiological studies: the model is monitored by two independent active components: the ribs with a kinematics law and the diaphragm tendon with an up and down translation. Other soft-tissue components are passively deformed using a 3D extension of the ChainMail algorithm. The respiration rate is also tunable to modify the respiratory profile. Results: We have extended the simulation pipeline to take into account focal spots that cause geometric unsharpness and polychromatic X-rays, and dynamic polygon meshes of a breathing patient can be used as input data. Conclusions: X-ray transmission images can be fully simulated on the GPU, by using the Beer-Lambert law with polychromatism and taking into account the shape of the source. The respiration of the patient can be modeled to produce dynamic meshes. This is a useful development to improve the level of realism in simulations, when it is needed to retain both speed and accuracy

    Real time monitoring of the Bragg-peak position in ion therapy by means of single photon detection

    No full text
    For real-time monitoring of the longitudinal position of the Bragg-peak during an ion therapy treatment, a novel non-invasive technique has been recently proposed that exploits the detection of prompt -rays issued from nuclear fragmentation. Two series of experiments have been performed at the GANIL and GSI facilities with 95 MeV/u and 305 MeV/u 12C6+ ion beams stopped in PMMA and water phantoms. In both experiments a clear correlation was obtained between the carbon ion range and the prompt photon profile. Additionally, an extensive study has been performed to investigate whether a prompt neutron component may be correlated with the carbon ion range. No such correlation was found. The present paper demonstrates that a collimated set-up can be used to detect single photons by means of time-of-flight measurements, at those high energies typical for ion therapy. Moreover, the applicability of the technique both at cyclotron and synchrotron facilities is shown. It is concluded that the detected photon count rates provide sufficiently high statistics to allow real-time control of the longitudinal position of the Bragg-peak under clinical conditions

    Development of a Compton camera for medical applications based on silicon strip and scintillation detectors

    Get PDF
    International audienceA Compton camera is being developed for the purpose of ion-range monitoring during hadrontherapy via the detection of prompt-gamma rays. The system consists of a scintillating fiber beam tagging hodoscope, a stack of double sided silicon strip detectors (90 Â 90 Â 2 mm 3 , 2 Â 64 strips) as scatter detectors, as well as bismuth germanate (BGO) scintillation detectors (38 Â 35 Â 30 mm 3 , 100 blocks) as absorbers. The individual components will be described, together with the status of their characterization

    Cross-detector scatter issues in dual synchronous tomography: An affine projection correction protocol

    No full text
    International audienceDual-beam x-ray tomography systems are paving the way for new experimental procedures, such as multi-resolution and multi-energy imaging, where synchronous acquisitions are essential. However, in such systems, cross-detector scatter between the detecting devices can occur as the two beamlines operate simultaneously. This paper proposes a new affine image transformation model of each projection to correct for these cross-detector scatter issues. A toy tomography test case is presented to assess the feasibility and performance of the proposed correction method

    Convolution-based scatter correction using kernels combining measurements and Monte Carlo simulations

    No full text
    International audienceOne of the well-recognized challenge of Cone-Beam Computed Tomography (CBCT) is scatter contamination within the projection images. Scatter degrades the image quality by decreasing the contrast, introducing cupping and shading artifacts and thus leading to inaccuracies in the reconstructed values. The higher scatter to primary ratio experienced in industrial applications leads to even more important artifacts. Various strategies have been investigated to manage the scatter signal in CBCT projection data. One of these strategies is to calculate the scatter intensity by deconvolution of primary intensity using Scatter Kernel Superposition (SKS). In this paper, we present an approach combining experimental measurements and Monte Carlo simulations to estimate the scatter kernels for industrial applications based on the continuously thickness-adapted kernels strategy with a four-Gaussian modeling of kernels. We compare this approach with an experimental technique based on a two-Gaussian modeling of the kernels. The results obtained prove the superiority of a four-Gaussian model to effectively take into account both the contribution of object and detector scattering as compared to a two-Gaussian approach. We also present the parameterisation of the scatter kernels with respect to object to detector distance. This approach facilitates the use of a single geometry for calculation of scatter kernels over the whole magnification range of the acquisition setup

    Prompt-gamma monitoring in hadrontherapy: A review

    No full text
    International audienceSecondary radiation emission induced by nuclear reactions is correlated to the path of ions in matter. Therefore, such penetrating radiation can be used for in vivo control of hadrontherapy treatments, for which the primary beam is absorbed inside the patient. Among secondary radiations, prompt-gamma rays were proposed for real-time verification of ion range. Such a verification is a desired condition to reduce uncertainties in treatment planning. For more than a decade, efforts have been undertaken worldwide to promote prompt-gamma-based devices to be used in clinical conditions. Dedicated cameras are necessary to overcome the challenges of a broad- and high-energy distribution, a large background, high instantaneous count rates, and compatibility constraints with patient irradiation. Several types of prompt-gamma imaging devices have been proposed, that are either physically-collimated or electronically collimated (Compton cameras). Clinical tests are now undergoing. Meanwhile, other methods than direct prompt-gamma imaging were proposed, that are based on specific counting using either time-of-flight or photon energy measurements. In the present article, we make a review and discuss the state of the art for all techniques using prompt-gamma detection to improve the quality assurance in hadrontherapy

    Mieux conserver la sardine à bord des chalutiers

    No full text
    International audienceBy the sea side, Sardine is a well appreciated fish by the consumers. It represents an important part of the French fishings (14% of sales in july 1999). The early use of cold after fishing is necessary to improve the freshness of sardine and to improve sales. This article recalls the main fishing techniques and presents the advantages and the drawbacks of on board cooling processes : icing, the most common technique, is little efficient and of an awkward use. Immersion techniques ensure a fast refrigeration but the "on-board" stake does still need improvement. Researchers and fishermen have associated themselves to improve the cooling techniques, especially on board.La sardine, poisson particulièrement apprécié des consommateurs en bord de mer, représente une part non négligeable des pêches françaises (14% des ventes en juillet 1999). L'application précoce du froid après la pêche est indispensable pour garantir sa fraîcheur et faciliter sa commercialisation. Cet article rappelle les principales techniques de pêche et présente en particulier les avantages et les inconvénients des procédés de refroidissement : la glace "écaille", le plus commun, est peu efficace et d'un emploi malcommode. Les techniques d'immersion assurent un refroidissement rapide mais la mise en oeuvre à bord n'est pas encore satisfaisante. Chercheurs et professionnels se sont associés pour améliorer les techniques de refroidissement et, à terme, les rendre opérationnelles à bord

    CHARACTERISING THE EOS SLOT-SCANNING SYSTEM WITH THE EFFECTIVE DETECTIVE QUANTUM EFFICIENCY.

    No full text
    As opposed to the standard detective quantum efficiency (DQE), effective DQE (eDQE) is a figure of merit that allows comparing the performances of imaging systems in the presence of scatter rejection devices. The geometry of the EOS™ slot-scanning system is such that the detector is self-collimated and rejects scattered radiation. In this study, the EOS system was characterised using the eDQE in imaging conditions similar to those used in clinical practice: with phantoms of different widths placed in the X-ray beam, for various incident air kerma and tube voltages corresponding to the phantom thickness. Scatter fractions in EOS images were extremely low, around 2 % for all configurations. Maximum eDQE values spanned 9-14.8 % for a large range of air kerma at the detector plane from 0.01 to 1.34 µGy. These figures were obtained with non-optimised EOS setting but still over-performed most of the maximum eDQEs recently assessed for various computed radiology and digital radiology systems with antiscatter grids