1,267 research outputs found

    Post-operative deep brain stimulation assessment: Automatic data integration and report generation.

    Get PDF
    BACKGROUND: The gold standard for post-operative deep brain stimulation (DBS) parameter tuning is a monopolar review of all stimulation contacts, a strategy being challenged by recent developments of more complex electrode leads. OBJECTIVE: Providing a method to guide clinicians on DBS assessment and parameter tuning by automatically integrating patient individual data. METHODS: We present a fully automatic method for visualization of individual deep brain structures in relation to a DBS lead by combining precise electrode recovery from post-operative imaging with individual estimates of deep brain morphology utilizing a 7T-MRI deep brain atlas. RESULTS: The method was evaluated on 20 STN DBS cases. It demonstrated robust automatic creation of 3D-enabled PDF reports visualizing electrode to brain structure relations and proved valuable in detecting miss placed electrodes. DISCUSSION: Automatic DBS assessment is feasible and can conveniently provide clinicians with relevant information on DBS contact positions in relation to important anatomical structures

    The evolution of precipitate crystal structures in an Al-Mg-Si(-Cu) alloy studied by a combined HAADF-STEM and SPED approach

    Get PDF
    This work presents a detailed investigation into the effect of a low Cu addition (0.01 at.%) on precipitation in an Al-0.80Mg-0.85Si alloy during ageing. The precipitate crystal structures were assessed by scanning transmission electron microscopy combined with a novel scanning precession electron diffraction approach, which includes machine learning. The combination of techniques enabled evaluation of the atomic arrangement within individual precipitates, as well as an improved estimate of precipitate phase fractions at each ageing condition, through analysis of a statistically significant number of precipitates. Based on the obtained results, the total amount of solute atoms locked inside precipitates could be approximated. It was shown that even with a Cu content close to impurity levels, the Al-Mg-Si system precipitation was significantly affected with overageing. The principal change was due to a gradually increasing phase fraction of the Cu-containing Q'-phase, which eventually was seen to dominate the precipitate structures. The structural overtake could be explained based on a continuous formation of the thermally stable Q'-phase, with Cu atomic columns incorporating less Cu than what could potentially be accommodated.Comment: 13 pages, 10 figures, 2 table

    Staphylococcus cornubiensis sp. nov., a member of the Staphylococcus intermedius Group (SIG)

    Get PDF
    This is the author accepted manuscript. The final version is available from Microbiology Society via the DOI in this recordWe here describe a novel species in the Staphylococcus intermedius Group (SIG) which is phenotypically similar to Staphylococcus pseudintermedius but is genomically distinct from it and other SIG members, with an average nucleotide identity of 90.2 % with its closest relative S. intermedius. The description of Staphylococcus cornubiensis sp. nov. is based on strain NW1T (=NCTC 13950T=DSM 105366T) isolated from a human skin infection in Cornwall, UK. Although pathogenic, NW1T carries no known virulence genes or mobilizable antibiotic resistance genes and further studies are required to assess the prevalence of this species in humans as well as its potential presence in companion animals.This work was supported by the Wellcome Trust (grant WT 098051). We acknowledge BBSRC/MRC funding (grant MR/N007174/1) enabling discounted sequencing through the microbesNG program

    Protein fiber linear dichroism for structure determination and kinetics in a low-volume, low-wavelength couette flow cell

    Get PDF
    High-resolution structure determination of soluble globular proteins relies heavily on x-ray crystallography techniques. Such an approach is often ineffective for investigations into the structure of fibrous proteins as these proteins generally do not crystallize. Thus investigations into fibrous protein structure have relied on less direct methods such as x-ray fiber diffraction and circular dichroism. Ultraviolet linear dichroism has the potential to provide additional information on the structure of such biomolecular systems. However, existing systems are not optimized for the requirements of fibrous proteins. We have designed and built a low-volume (200 μL), low-wavelength (down to 180 nm), low-pathlength (100 μm), high-alignment flow-alignment system (couette) to perform ultraviolet linear dichroism studies on the fibers formed by a range of biomolecules. The apparatus has been tested using a number of proteins for which longer wavelength linear dichroism spectra had already been measured. The new couette cell has also been used to obtain data on two medically important protein fibers, the all-β-sheet amyloid fibers of the Alzheimer's derived protein Aβ and the long-chain assemblies of α1-antitrypsin polymers

    Digestibility in selected rainbow trout families and modelling of growth from the specific intake of digestible protein

    Get PDF
    The experiments aimed to clarify variations in digestibility of dietary nutrients in rainbow trout. Furthermore, the objective was to study how differences in digestibility might be related to growth and feed utilisation at various growth rates. When comparing the results from the experiments it appeared that particularly protein digestibility was closely related to specific growth rate and feed conversion ratio at high growth rates. As a tool to visualise the relationship between protein digestibility and growth of rainbow trout a growth model was developed based on the specific intake of digestible protein, and general assumptions on protein content and protein retention efficiency in rainbow trout. The model indicated that increased protein digestibility only partly explained growth increase and that additional factors were important for growth increment

    Establishing quality indicators for prehospital advanced airway management: a modified nominal group technique consensus process

    Get PDF
    Background: Prehospital advanced airway management is a complex intervention composed of numerous steps, interactions, and variables that can be delivered to a high standard in the prehospital setting. Standard research methods have struggled to evaluate this complex intervention because of considerable heterogeneity in patients, providers, and techniques. In this study, we aimed to develop a set of quality indicators to evaluate prehospital advanced airway management. Methods: We used a modified nominal group technique consensus process comprising three email rounds and a consensus meeting among a group of 16 international experts. The final set of quality indicators was assessed for usability according to the National Quality Forum Measure Evaluation Criteria. Results: Seventy-seven possible quality indicators were identified through a narrative literature review with a further 49 proposed by panel experts. A final set of 17 final quality indicators composed of three structure-, nine process-, and five outcome-related indicators, was identified through the consensus process. The quality indicators cover all steps of prehospital advanced airway management from preoxygenation and use of rapid sequence induction to the ventilatory state of the patient at hospital delivery, prior intubation experience of provider, success rates and complications. Conclusions: We identified a set of quality indicators for prehospital advanced airway management that represent a practical tool to measure, report, analyse, and monitor quality and performance of this complex intervention.publishedVersio

    Standardised data reporting from pre-hospital advanced airway management - a nominal group technique update of the Utstein-style airway template

    Get PDF
    Background Pre-hospital advanced airway management with oxygenation and ventilation may be vital for managing critically ill or injured patients. To improve pre-hospital critical care and develop evidence-based guidelines, research on standardised high-quality data is important. We aimed to identify which airway data were most important to report today and to revise and update a previously reported Utstein-style airway management dataset. Methods We recruited sixteen international experts in pre-hospital airway management from Australia, United States of America, and Europe. We used a five-step modified nominal group technique to revise the dataset, and clinical study results from the original template were used to guide the process. Results The experts agreed on a key dataset of thirty-two operational variables with six additional system variables, organised in time, patient, airway management and system sections. Of the original variables, one remained unchanged, while nineteen were modified in name, category, definition or value. Sixteen new variables were added. The updated dataset covers risk factors for difficult intubation, checklist and standard operating procedure use, pre-oxygenation strategies, the use of drugs in airway management, airway currency training, developments in airway devices, airway management strategies, and patient safety issues not previously described. Conclusions Using a modified nominal group technique with international airway management experts, we have updated the Utstein-style dataset to report standardised data from pre-hospital advanced airway management. The dataset enables future airway management research to produce comparable high-quality data across emergency medical systems. We believe this approach will promote research and improve treatment strategies and outcomes for patients receiving pre-hospital advanced airway management.publishedVersio

    Blue-enriched white light improves performance but not subjective alertness and circadian adaptation during three consecutive simulated night shifts

    Get PDF
    Use of blue-enriched light has received increasing interest regarding its activating and performance sustaining effects. However, studies assessing effects of such light during night work are few, and novel strategies for lighting using light emitting diode (LED) technology need to be researched. In a counterbalanced crossover design, we investigated the effects of a standard polychromatic blue-enriched white light (7000 K; ∼200 lx) compared to a warm white light (2500 K), of similar photon density (∼1.6 × 1014 photons/cm2/s), during three consecutive simulated night shifts. A total of 30 healthy participants [10 males, mean age 23.3 (SD = 2.9) years] were included in the study. Dependent variables comprised subjective alertness using the Karolinska Sleepiness Scale, a psychomotor vigilance task (PVT) and a digit symbol substitution test (DSST), all administered at five time points throughout each night shift. We also assessed dim-light melatonin onset (DLMO) before and after the night shifts, as well as participants’ opinion of the light conditions. Subjective alertness and performance on the PVT and DSST deteriorated during the night shifts, but 7000 K light was more beneficial for performance, mainly in terms of fewer errors on the PVT, at the end of the first- and second- night shift, compared to 2500 K light. Blue-enriched light only had a minor impact on PVT response times (RTs), as only the fastest 10% of the RTs were significantly improved in 7000 K compared to 2500 K light. In both 7000 and 2500 K light, the DLMO was delayed in those participants with valid assessment of this parameter [n = 20 (69.0%) in 7000 K light, n = 22 (78.6%) in 2500 K light], with a mean of 2:34 (SE = 0:14) and 2:12 (SE = 0:14) hours, respectively, which was not significantly different between the light conditions. Both light conditions were positively rated, although participants found 7000 K to be more suitable for work yet evaluated 2500 K light as more pleasant. The data indicate minor, but beneficial, effects of 7000 K light compared to 2500 K light on performance during night work. Circadian adaptation did not differ significantly between light conditions, though caution should be taken when interpreting these findings due to missing data. Field studies are needed to investigate similar light interventions in real-life settings, to develop recommendations regarding illumination for night workers.publishedVersio
    corecore