2,038 research outputs found
Photonic crystal resonator integrated in a microfluidic system
We report on a novel optofluidic system consisting of a silica-based 1D
photonic crystal, integrated planar waveguides and electrically insulated
fluidic channels. An array of pillars in a microfluidic channel designed for
electrochromatography is used as a resonator for on-column label-free
refractive index detection. The resonator was fabricated in a silicon
oxynitride platform, to support electroosmotic flow, and operated at 1.55
microns. Different aqueous solutions of ethanol with refractive indices ranging
from n = 1.3330 to 1.3616 were pumped into the column/resonator and the
transmission spectra were recorded. Linear shifts of the resonant wavelengths
yielded a maximum sensitivity of 480 nm/RIU and a minimum difference of 0.007
RIU was measured
Combined modality treatment with full-dose chemotherapy and concomitant boost radiotherapy for advanced head and neck carcinoma
The purpose of this study was to evaluate the feasibility and efficacy of a treatment concept combining three cycles of full-dose chemotherapy (CT) with concomitant accelerated uninterrupted radiotherapy (RT). Twenty-three patients (median age: 54 years, range: 35-70) with locally advanced squamous cell carcinoma of the head and neck (SCCHN) were included. The primary tumor involved the hypopharynx (n=7), base of the tongue (n=10), nasopharynx (n=2) or upper esophagus (n=1) or its location was unknown (n=3). Treatment consisted of three cycles of chemotherapy (cisplatin 100 mg/m2 on day 1; 5-FU 1,000 mg/m2 per day for 5 days as a continuous infusion, preceded by amifostine 910 mg/m2), repeated every 3 weeks. Uninterrupted concomitant boost-accelerated RT (total dose of 70 Gy in 6 weeks) started together on day 1 of the second cycle. All but two patients received the full course of RT. Eighteen patients achieved complete remission (78%). At a median follow-up of 45 months the overall survival was 56% (95% c.i. 32-79%) and the loco-regional control 71% (95% c.i. 52-91%). Toxicity involved reversible renal insufficiency of > or = grade II in 9 patients (39%) and neutropenic fever in 9 patients (39%). All patients suffered from moderate to severe mucositis (grade II/III), and 19 patients presented cutaneous toxicity grade III. Concomitant boost-accelerated RT combined with concurrent full-dose cisplatin/5-FU chemotherapy and amifostine is feasible with manageable, although substantial, toxicity. The overall survival of 4 years is promising. Newer regimens causing less acute mucosal and skin toxicity are needed
Electrocardiographic alterations during intravascular application of three different test doses of bupivacaine and epinephrine: experimental study in neonatal pigs
Background Origin of electrocardiographic (ECG) alterations during intravascular injection of local anaesthetic solutions is controversial. The aim of this study was to elucidate whether epinephrine, bupivacaine or their combination is responsible for ECG alteration. Methods Forty-five piglets were randomized into three groups. After induction of general anaesthesia using sevoflurane and peripheral venous cannulation, the trachea was intubated, the lungs were artificially ventilated, and anaesthesia was maintained by sevoflurane. Under steady state 0.2 ml kgâ1 and after 10 min 0.4 ml kgâ1 of one of the following three test solutions was administered i.v.: bupivacaine 0.125% (Group 1), bupivacaine 0.125%+epinephrine 1:200 000 (Group 2), and plain epinephrine 1:200 000 (Group 3). The ECG was analysed for alterations in heart rate and T-elevation. Results After injection of 0.2 or 0.4 ml kgâ1 test solution, an increase in heart rate of at least 10% was found in none of Group 1 and in all of Groups 2 and 3. After application of 0.2 ml kgâ1 test solution, T-elevation was found in 7% of Group 1 and in 93% of Groups 2 and 3. The injection of 0.4 ml kgâ1 revealed a T-elevation in 27%, 100%, and 100%, respectively, in Groups 1, 2, and 3. Conclusions This animal model demonstrated that increases in heart rate and T-elevation in the ECG during i.v. application of a common test dose (0.2 ml kgâ1) of bupivacaine are caused by epinephrine addition. Whether higher doses of bupivacaine alone can cause similar ECG changes or not requires further studie
Integration of a zero dead-volume PDMS rotary switch valve in a miniaturised (bio)electroanalytical system
This work features the design, fabrication and characterisation of a miniaturised electroanalytical lab on a chip that allows the performance of a complete bioassay, from the capture of magnetic particles through their functionalisation and sample incubation to the detection of electroactive reaction products. The system is built using mainly polymeric materials such as PMMA and PDMS and fast prototyping techniques such as milling and moulding. The system also includes a set of microelectrodes, photo-lithographed on a silicon chip. The novelty lies in the design of the rotary microvalve, which contains a microreactor so that various reaction and incubation steps can be carried out in isolation from the detection event with zero dead volume. This avoids contamination and fouling of the electrodes by proteins or other organic matter, and extends the useful lifetime of the detector. The system operation is demonstrated by a model example, consisting in the functionalisation of streptavidin-coated magnetic particles with biotinylated ÎČ-galactosidase over periods ranging from 5 to 15 minutes, at which point the particles saturate. Although the system is intended for the development of enzyme-based electrochemical bioassays, the concept of its rotary microreactor can be applied more broadly.Peer reviewe
Electrocardiographic changes during continuous intravenous application of bupivacaine in neonatal pigs
Background It is controversial as to whether T-wave elevation is caused by local anaesthetics, epinephrine, or their combination. It has been shown that T-elevation after intravascular injection of a small bupivacaine test dose is caused by epinephrine and not by bupivacaine. The aim of this study was to investigate ECG changes with higher doses of i.v. bupivacaine. Methods Thirty neonatal pigs were anaesthetized with sevoflurane and their tracheas intubated and artificially ventilated. Under steady-state conditions, bupivacaine was continuously infused (flow rate 3.2 ml kgâ1 minâ1) by a syringe infusion pump through a central venous catheter. Group 1 received bupivacaine 0.125%, Group 2 bupivacaine 0.5%. The ECG was continuously printed and subsequently analysed for alterations in heart rate, ventricular de- and repolarization, and arrhythmias at 1.25, 2.5, and 5 mg kgâ1 bupivacaine infused. Results Sinus rhythm persisted in all pigs. Heart rate decreased progressively in both groups, but this was significantly more pronounced in Group 1. T-wave elevation occurred in 40% and 0% (Groups 1 and 2) at 1.25 mg kgâ1, in 80% and 0% at 2.5 mg kgâ1, and in 93% and 80% at 5 mg kgâ1 bupivacaine infused. There were significant differences between the two groups at 1.25 and 2.5 mg kgâ1 infused. Conclusions Higher doses of i.v. infused bupivacaine can cause T-elevation. With slower injection technique, T-elevation can already be detected at lower bupivacaine doses administere
Acoustic resonances in microfluidic chips: full-image micro-PIV experiments and numerical simulations
We show that full-image micro-PIV analysis in combination with images of
transient particle motion is a powerful tool for experimental studies of
acoustic radiation forces and acoustic streaming in microfluidic chambers under
piezo-actuation in the MHz range. The measured steady-state motion of both
large 5 um and small 1 um particles can be understood in terms of the acoustic
eigenmodes or standing ultra-sound waves in the given experimental
microsystems. This interpretation is supported by numerical solutions of the
corresponding acoustic wave equation.Comment: RevTex, 10 pages, 9 eps figures; NOTE first authors changed his name
to S. Melker Hagsater in the published versio
Scintillator counters with WLS fiber/MPPC readout for the side muon range detector (SMRD)of the T2K experiment
The T2K neutrino experiment at J-PARC uses a set of near detectors to measure
the properties of an unoscillated neutrino beam and neutrino interaction
cross-sections. One of the sub-detectors of the near-detector complex, the side
muon range detector (SMRD), is described in the paper. The detector is designed
to help measure the neutrino energy spectrum, to identify background and to
calibrate the other detectors. The active elements of the SMRD consist of 0.7
cm thick extruded scintillator slabs inserted into air gaps of the UA1 magnet
yokes. The readout of each scintillator slab is provided through a single WLS
fiber embedded into a serpentine shaped groove. Two Hamamatsu multi-pixel
avalanche photodiodes (MPPC's) are coupled to both ends of the WLS fiber. This
design allows us to achieve a high MIP detection efficiency of greater than
99%. A light yield of 25-50 p.e./MIP, a time resolution of about 1 ns and a
spatial resolution along the slab better than 10 cm were obtained for the SMRD
counters.Comment: 7 pages, 4 figures; talk at TIPP09, March 12-17, Tsukuba, Japan; to
be published in the conference proceeding
The T2K Side Muon Range Detector
The T2K experiment is a long baseline neutrino oscillation experiment aiming
to observe the appearance of {\nu} e in a {\nu}{\mu} beam. The {\nu}{\mu} beam
is produced at the Japan Proton Accelerator Research Complex (J-PARC), observed
with the 295 km distant Super- Kamiokande Detector and monitored by a suite of
near detectors at 280m from the proton target. The near detectors include a
magnetized off-axis detector (ND280) which measures the un-oscillated neutrino
flux and neutrino cross sections. The present paper describes the outermost
component of ND280 which is a side muon range detector (SMRD) composed of
scintillation counters with embedded wavelength shifting fibers and Multi-Pixel
Photon Counter read-out. The components, performance and response of the SMRD
are presented.Comment: 13 pages, 19 figures v2: fixed several typos; fixed reference
Combined Analysis of all Three Phases of Solar Neutrino Data from the Sudbury Neutrino Observatory
We report results from a combined analysis of solar neutrino data from all
phases of the Sudbury Neutrino Observatory. By exploiting particle
identification information obtained from the proportional counters installed
during the third phase, this analysis improved background rejection in that
phase of the experiment. The combined analysis resulted in a total flux of
active neutrino flavors from 8B decays in the Sun of (5.25 \pm
0.16(stat.)+0.11-0.13(syst.))\times10^6 cm^{-2}s^{-1}. A two-flavor neutrino
oscillation analysis yielded \Deltam^2_{21} = (5.6^{+1.9}_{-1.4})\times10^{-5}
eV^2 and tan^2{\theta}_{12}= 0.427^{+0.033}_{-0.029}. A three-flavor neutrino
oscillation analysis combining this result with results of all other solar
neutrino experiments and the KamLAND experiment yielded \Deltam^2_{21} =
(7.41^{+0.21}_{-0.19})\times10^{-5} eV^2, tan^2{\theta}_{12} =
0.446^{+0.030}_{-0.029}, and sin^2{\theta}_{13} =
(2.5^{+1.8}_{-1.5})\times10^{-2}. This implied an upper bound of
sin^2{\theta}_{13} < 0.053 at the 95% confidence level (C.L.)
- âŠ