104 research outputs found
GEC-ESTRO ACROP recommendations in skin brachytherapy
Purpose: The aim of this publication is to compile available literature data and expert experience regarding skin brachytherapy (BT) in order to produce general recommendations on behalf of the GEC-ESTRO Group. Methods: We have done an exhaustive review of published articles to look for general recommendations. Results: Randomized controlled trials, systemic reviews and meta-analysis are lacking in literature and there is wide variety of prescription techniques successfully used across the radiotherapy centers. BT can be delivered as superficial application (also called contact BT or plesiotherapy) or as interstitial for tumours thicker than 5 mm within any surface, including very irregular. In selected cases, particularly in tumours located within curved surfaces, BT can be advantageous modality from dosimetric and planning point of view when compared to external beam radiotherapy. The general rule in skin BT is that the smaller the target volume, the highest dose per fraction and the shortest overall length of treatment can be used. Conclusion: Skin cancer incidence is rising worldwide. BT offers an effective non-invasive or minimally invasive and relative short treatment that particularly appeals to elder and frail population
Acute neuromuscular and perceptual responses to blood flow restriction exercise in adults with severe haemophilia:A pilot study
Introduction: No previous studies have implemented a standard blood flow restriction (BFR) training session in people with severe haemophilia (PwH), where this type of training has been contraindicated.Aims: The purpose of this study was to evaluate the tolerability, adverse events, and neuromuscular and perceptual responses to an acute session of low load (LL) knee extensions with BFR in PwH under prophylaxis.Methods: Eight PwH performed one LL-BFR session with 40% arterial occlusion pressure (AOP). Perceptual responses and adverse effects were assessed, together with high-density surface electromyography of vastusmedialis (VM) and lateralis (VL).Results: Significant normalized root mean square differences were found within each set, but not between sets. Spatial distribution (centroid displacement (p > .05), modified entropy (VM, set two, cycles three and five, p = .032) and coefficient of variation (VM, set two, cycles four and five lower than cycle three (p = .049; p = .036)) showed changes within each set.Median frequency showed a slight increase during cycle four of set four (p = .030). Rate of perceived exertion slightly increased with each set while tolerability slightly decreased in the last set and fear of training with BFR generally decreased after the session.Conclusions: In PwH, a LL-BFR session at 40% AOP is safe and feasible. Our results suggest that potential muscle impairments may blunt neuromuscular adaptations induced by BFR
Monte Carlo flattening filter design to high energy intraoperative electron beam homogenization
[EN] Intraoperative radiotherapy using mobile linear accelerators is used for a wide variety of malignancies. However, when large fields are used in combination with high energies, a deterioration of the flatness dose profile is measured with respect to smaller fields and lower energies. Indeed, for the LIAC HWL of Sordina, this deterioration is observed for the 12 MeV beam combined with 10 cm (or larger) diameter applicator. Aimed to solve this problem, a flattening filter has been designed and validated evaluating the feasibility of its usage at the upper part of the applicator. The design of the filter was based on Monte Carlo simulations because of its accuracy in modeling components of clinical devices, among other purposes. The LIAC 10 cm diameter applicator was modeled and simulated independently by two different research groups using two different MC codes, reproducing the heterogeneity of the 12 MeV energy beam. Then, an iterative process of filter design was carried out. Finally, the MC designed conical filter with the optimal size and height to obtain the desired flattened beam was built in-house using a 3D printer. During the experimental validation of the applicator-filter, percentage depth dose, beam profiles, absolute and peripheral dose measurements were performed to demonstrate the effectiveness of the filter addition in the applicator. These measurements conclude that the beam has been flattened, from 5.9% with the standard configuration to 1.6% for the configuration with the filter, without significant increase of the peripheral dose. Consequently, the new filter-applicator LIAC configuration can be used also in a conventional surgery room. A reduction of 16% of the output dose and a reduction of 1.1 mm in the D50 of the percentage depth dose was measured with respect to the original configuration. This work is a proof-of-concept that demonstrates that it is possible to add a filter able to flatten the beam delivered by the Sordina LIAC HWL. Future studies will focus on more refined technical solutions fully compatible with the integrity of the applicator, including its sterilization, to be safely introduced in the clinical practice.The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Giuseppe Felici reports a relationship with S.I.T. Sordina IORT Technologies S.p.A. that includes: employment. We thank the professionals and facilities at the 3D printing and metrology department in the Mechanics Unit at IFIC. JV thanks I. Diaz for measuring the PLA density. We thank S.I.T. SORDINA IORT Tech-nologies SpA for providing the applicator used for testing the filter during the measurements. JV, FB, and JP would like to acknowledge the Spanish "Ministerio de Ciencia e Innovacion" (MCIN) grant PID2021-125096NB-I00 funded by MCIN/AEI/10.13039 and the "Generalitat Valenciana" (GVA) grant PROMETEO/2021/064.Oliver-Gil, S.; Vijande, J.; Tejedor-Aguilar, N.; Miró Herrero, R.; Rovira-Escutia, JJ.; Ballester, F.; Juste-Vidal, B.... (2023). Monte Carlo flattening filter design to high energy intraoperative electron
beam homogenization. Radiation Physics and Chemistry. 212. https://doi.org/10.1016/j.radphyschem.2023.11110221
A simple analytical method for heterogeneity corrections in low dose rate prostate brachytherapy
In low energy brachytherapy, the presence of tissue heterogeneities contributes significantly to the discrepancies observed between treatment plan and delivered dose. In this work, we present a simplified analytical dose calculation algorithm for heterogeneous tissue. We compare it with Monte Carlo computations and assess its suitability for integration in clinical treatment planning systems. The algorithm, named as RayStretch, is based on the classic equivalent path length method and TG-43 reference data. Analytical and Monte Carlo dose calculations using Penelope2008 are compared for a benchmark case: a prostate patient with calcifications. The results show a remarkable agreement between simulation and algorithm, the latter having, in addition, a high calculation speed. The proposed analytical model is compatible with clinical real-time treatment planning systems based on TG-43 consensus datasets for improving dose calculation and treatment quality in heterogeneous tissue. Moreover, the algorithm is applicable for any type of heterogeneities
Erratum to: 36th International Symposium on Intensive Care and Emergency Medicine
[This corrects the article DOI: 10.1186/s13054-016-1208-6.]
- …