448 research outputs found

    The TEAM instrument for measuring emergency team performance: validation of the Swedish version at two emergency departments

    Get PDF
    Background: The Team Emergency Assessment Measure (TEAM) questionnaire is designed for rating the non-technical performance of emergency medical teams during emergencies, e.g., resuscitation or trauma management. Originally developed in Australia it has today been translated and validated into eleven languages, but a Swedish version is lacking. The aim was therefore to cross-culturally translate and evaluate the reliability and validity of the TEAM questionnaire in a Swedish health care setting. Methods: The instrument was forward and backward translated and adapted into a Swedish context according to established guidelines for cross-cultural adaptation of survey-based measures. The translated version was tested through 78 pairwise assessments of 39 high-priority codes at the emergency departments of two major hospitals. The raters observed the teams at work in real time and filled in the questionnaires immediately afterwards independently of each other. Psychometric properties of the instrument were evaluated. Results: The original instrument was translated by pairs of translators independently of each other and reviewed by an expert committee of researchers, nurses and physicians from different specialties, a linguist and one of the original developers of the tool. A few adaptations were needed for the Swedish context. A principal component factor analysis confirmed a single ‘teamwork’ construct in line with the original instrument. The Swedish version showed excellent reliability with a Cronbach’s alpha of 0.955 and a mean inter-item correlation of 0.691. The mean item-scale correlation of 0.82 indicated high internal consistency reliability. Inter-rater reliability was measured by intraclass correlation and was 0.74 for the global score indicating good reliability. Individual items ranged between 0.52 and 0.88. No floor effects but ceiling effects were noted. Finally, teams displaying clear closed-loop communication had higher TEAM scores than teams with less clear communication. Conclusions: Real time observations of authentic, high priority cases at two emergency departments show that the Swedish version of the TEAM instrument has good psychometric properties for evaluating team performance. The TEAM instrument is thus a welcome tool for assessing non-technical skills of emergency medical teams. © 2021, The Author(s). **Please note that there are multiple authors for this article therefore only the name of the first 5 including Federation University Australia affiliate “Simon Cooper" is provided in this record*

    High-pressure Raman study of L-alanine crystal

    Full text link
    Pressure-dependent Raman scattering studies in the range 0.0 -- 32 kbar were carried out in L-alanine in order to investigate its external mode phonon spectra in relation to the phase transitions in the crystal. A careful analysis of the spectra shows that the low-energy Raman modes exhibit variation both in frequency and in intensity and between 26 and 28 kbar it is observed a splitting of a external mode, indicating that the D_2 normal phase undergoes a transition. Pressure coefficients for external modes are also given.Comment: 11 pages, Latex, 2 figure

    CMC is more than a measure of corticospinal tract integrity in acute stroke patients

    Get PDF
    In healthy subjects, motor cortex activity and electromyographic (EMG) signals from contracting contralateral muscle show coherence in the beta (15-30 Hz) range. Corticomuscular coherence (CMC) is considered a sign of functional coupling between muscle and brain. Based on prior studies, CMC is altered in stroke, but functional significance of this finding has remained unclear. Here, we examined CMC in acute stroke patients and correlated the results with clinical outcome measures and corticospinal tract (CST) integrity estimated with diffusion tensor imaging (DTI). During isometric contraction of the extensor carpi radialis muscle, EMG and magneto encephalographic oscillatory signals were recorded from 29 patients with paresis of the upper extremity due to ischemic stroke and 22 control subjects. CMC amplitudes and peak frequencies at 13-30 Hz were compared between the two groups. In the patients, the peak frequency in both the affected and the unaffected hemisphere was significantly (p < 0.01) lower and the strength of CMC was significantly (p < 0.05) weaker in the affected hemisphere compared to the control subjects. The strength of CMC in the patients correlated with the level of tactile sensitivity and clinical test results of hand function. In contrast, no correlation between measures of CST integrity and CMC was found. The results confirm the earlier findings that CMC is altered in acute stroke and demonstrate that CMC is bidirectional and not solely a measure of integrity of the efferent corticospinal tract.Peer reviewe

    Euniwell: Maximising Academic And Social Outcomes In Engineering Education

    Get PDF
    The ERASMUS+ European University for Well-Being (EUniWell) alliance’s mission aims to resolve the paradox of Europeans’ relative prosperity against the global security and sustainability challenge. “Maximising Academic and Social Outcomes in Engineering Education” is a project which interprets this contradiction for engineering educators; how to best teach non-technical skills to ensure engineers make the utmost contribution to societal wellbeing? Appreciably, the social outcome for the person who becomes an engineer is positive because the profession is relatively well-paid. Therefore, engineering education is good for social mobility providing the learning environment narrows attainment gaps between disadvantaged and mainstream cohorts. Accordingly, our strategy is to bring together the expertise of the British, French, Italian and Swedish faculties to transfer best practice for professional, business and sustainability skill teaching, while contrasting how their disadvantaged cohorts present. The project has two primary objectives: To understand how partners differ in terms of skill teaching, and how students from disadvantaged backgrounds are accommodated. The paper describes the background and rationale of the project, and its research design and methodology. Although the project is still in progress and data collection is still underway, this paper provides insights and perspectives for engineering educators looking to design similar collaborations to share best practice, while considering engineering identities and their underlying competencies

    Integration of tools for binding archetypes to SNOMED CT

    Get PDF
    Background The Archetype formalism and the associated Archetype Definition Language have been proposed as an ISO standard for specifying models of components of electronic healthcare records as a means of achieving interoperability between clinical systems. This paper presents an archetype editor with support for manual or semi-automatic creation of bindings between archetypes and terminology systems. Methods Lexical and semantic methods are applied in order to obtain automatic mapping suggestions. Information visualisation methods are also used to assist the user in exploration and selection of mappings. Results An integrated tool for archetype authoring, semi-automatic SNOMED CT terminology binding assistance and terminology visualization was created and released as open source. Conclusion Finding the right terms to bind is a difficult task but the effort to achieve terminology bindings may be reduced with the help of the described approach. The methods and tools presented are general, but here only bindings between SNOMED CT and archetypes based on the openEHR reference model are presented in detail. Background The Archetype formalism and the associated Archetype Definition Language have been proposed as an ISO standard for specifying models of components of electronic healthcare records as a means of achieving interoperability between clinical systems. This paper presents an archetype editor with support for manual or semi-automatic creation of bindings between archetypes and terminology systems. Methods Lexical and semantic methods are applied in order to obtain automatic mapping suggestions. Information visualisation methods are also used to assist the user in exploration and selection of mappings. Results An integrated tool for archetype authoring, semi-automatic SNOMED CT terminology binding assistance and terminology visualization was created and released as open source. Conclusion Finding the right terms to bind is a difficult task but the effort to achieve terminology bindings may be reduced with the help of the described approach. The methods and tools presented are general, but here only bindings between SNOMED CT and archetypes based on the openEHR reference model are presented in detail.Original Publication: Erik Sundvall, Rahil Qamar, Mikael Nyström, Mattias Forss, HĂ„kan Petersson, Hans Åhlfeldt and Alan Rector, Integration of Tools for Binding Archetypes to SNOMED CT, 2008, BMC Medical Informatics and Decision Making, (8), S7. http://dx.doi.org/10.1186/1472-6947-8-S1-S7 Licensee: BioMed Central http://www.biomedcentral.com/</p

    FMDV replicons encoding green fluorescent protein are replication competent

    Get PDF
    The study of replication of viruses that require high bio-secure facilities can be accomplished with less stringent containment using non-infectious 'replicon' systems. The FMDV replicon system (pT7rep) reported by Mclnerney et al. (2000) was modified by the replacement of sequences encoding chloramphenicol acetyl-transferase (CAT) with those encoding a functional L proteinase (Lpro) linked to a bi-functional fluorescent/antibiotic resistance fusion protein (green fluorescent protein/puromycin resistance, [GFP-PAC]). Cells were transfected with replicon-derived transcript RNA and GFP fluorescence quantified. Replication of transcript RNAs was readily detected by fluorescence, whilst the signal from replication-incompetent forms of the genome was >2-fold lower. Surprisingly, a form of the replicon lacking the Lpro showed a significantly stronger fluorescence signal, but appeared with slightly delayed kinetics. Replication can, therefore, be quantified simply by live-cell imaging and image analyses, providing a rapid and facile alternative to RT-qPCR or CAT assays

    Enantiospecific pharmacokinetics of intravenous dexmedetomidine in beagles

    Get PDF
    The goal of this study was to investigate the pharmacokinetic (PK) behaviour of dexmedetomidine in dogs administered as a pure enantiomer versus as part of a racemic mixture. Eight unmedicated intact purpose-bread beagles were included. Two intravenous treatments of either medetomidine or dexmedetomidine were administered at 10- to 14-day intervals. Atipamezole or saline solution was administered intramuscularly 45&nbsp;min later. Venous blood samples were collected into EDTA collection tubes, and the quantification of dexmedetomidine and levomedetomidine was performed by chiral LC–MS/MS. All dogs appeared sedated after each treatment without complication. Plasma concentrations of levomedetomidine were measured only in the racemic group and were 51.4% (51.4%–56.1%) lower than dexmedetomidine. Non-compartmental analysis (NCA) was performed for both drugs, while dexmedetomidine data were further described using a population pharmacokinetic approach. A standard two-compartment mammillary model with linear elimination with combined additive and multiplicative error model for residual unexplained variability was established for dexmedetomidine. An exponential model was finally retained to describe inter-individual variability on parameters of clearance (Cl1) and central and peripheral volumes of distribution (V1, V2). No effect of occurrence, levomedetomidine or atipamezole could be observed on dexmedetomidine PK parameters. Dexmedetomidine did not undergo significantly different PK when administered alone or as part of the racemic mixture in otherwise unmedicated dogs

    Remineralization of demineralized dentin using a dual analog system.

    Get PDF
    ObjectiveImproved methods are needed to remineralize dentin caries in order to promote conservation of dentin tissue and minimize the surgical interventions that are currently required for clinical treatment. Here, we test the hypothesis that bulk substrates can be effectively mineralized via a dual analog system proposed by others, using a tripolyphosphate (TPP) "templating analog" and a poly(acrylic acid) (PAA) or poly(aspartic acid) (pAsp) "sequestration analog," the latter of which generates the polymer-induced liquid-precursor (PILP) mineralization process studied in our laboratory.Material &amp; methodsDemineralized human dentin slices were remineralized with and without pre-treatment with TPP, using either PAA or pAsp as the PILP process-directing agent. A control experiment with no polymer present was used for comparison.ResultsNo mineralization was observed in any of the PAA groups. In both the pAsp and no polymer groups, TPP inhibited mineralization on the surfaces of the specimens but promoted mineralization within the interiors. Pre-treatment with TPP enhanced overall mineralization of the pAsp group. However, when analysed via TEM, regions with little mineral were still present.ConclusionPoly(acrylic acid) was unable to remineralize demineralized dentin slices under the conditions employed, even when pre-treated with TPP. However, pre-treatment with TPP enhanced overall mineralization of specimens that were PILP-remineralized using pAsp
    • 

    corecore