1,123 research outputs found
Management of malignant pleural mesothelioma: a French multicenter retrospective study (GFPC 0802 study)
Expansion of elevational range in a forest pest: Can parasitoids track their hosts?
We are thankful to Karim Senhadji and Ramon Ruiz-Puche for their help during the field work, and to Sara Garcia Morato for her contribution to quantifying rates of parasitism in PPM clutches at the laboratory. Two anonymous referees contributed to improve the manuscript. This study was supported by projects PROPINOL (PN22/2008), GESBOME (P06-RNM-1890) from Junta de Andalucia, REMEDINAL TE-CM (S2018/EMT-4338) from Comunidad de Madrid, ADAPTAMED (LIFE14 CCA/ES/000612) from LIFE program, and GILES (PCIN-2016-150) from the ERANET-LAC H2020 Programme.Gradients in elevation impose changes in environmental conditions, which in turn modulate species distribution and abundance as well as the interactions they maintain. Along the gradient, interacting species (e.g., predators, parasitoids) can respond to changes in different ways. This study aims to investigate how egg parasitism of a forest pest, the pine processionary moth (PPM), Thaumetopoea pityocampa, vary along an elevational gradient (190-2000 m.a.s.l.) in a mountain range of SE Spain, including areas of recent elevational expansion, for a seven years period (2008-2014). We used generalized linear mixed models to ascertain the effect of both elevation and the winter North Atlantic Oscillation (NAO) index (a proxy of interannual climatic conditions) on the rate of parasitism, and the occurrence probabilities of two parasitoid species: a PPM specialist and a generalist species. Since four pine species are stratified along the elevational gradient, we repeated all the analyses separately for lowlands (190-1300 m. a.s.l.) and uplands (1350-2000 m. a.s.l.). Results showed a decrease in both parasitism rate and probability of occurrence of the two main parasitoid species with elevation, although decline was more severe for the specialist species. The effect of elevation was more conspicuous and intense in uplands than in lowlands. Positive NAO winter values, associated with cold and dry winters, reduced the rate of parasitism and the probability of occurrence of the two main parasitoid species-but particularly for the generalist species-as elevation increases. In a context of climate warming, it is crucial to mitigate PPM elevational and latitudinal expansion. Increasing tree diversity at the PPM expansion areas may favor the establishment of parasitoids, which could contribute to synchronizing host- parasitoid interactions and minimize the risk of PPM outbreaks.Junta de Andalucia
PN22/2008REMEDINAL TE-CM from Comunidad de Madrid
S2018/EMT-4338ADAPTAMED from LIFE program
LIFE14 CCA/ES/000612GILES from the ERANET-LAC H2020 Programme
PCIN-2016-150Junta de Andalucia
P06-RNM-189
Fast Photon Detection for Particle Identification with COMPASS RICH-1
Particle identification at high rates is an important challenge for many
current and future high-energy physics experiments. The upgrade of the COMPASS
RICH-1 detector requires a new technique for Cherenkov photon detection at
count rates of several per channel in the central detector region, and a
read-out system allowing for trigger rates of up to 100 kHz. To cope with these
requirements, the photon detectors in the central region have been replaced
with the detection system described in this paper. In the peripheral regions,
the existing multi-wire proportional chambers with CsI photocathode are now
read out via a new system employing APV pre-amplifiers and flash ADC chips. The
new detection system consists of multi-anode photomultiplier tubes (MAPMT) and
fast read-out electronics based on the MAD4 discriminator and the F1-TDC chip.
The RICH-1 is in operation in its upgraded version for the 2006 CERN SPS run.
We present the photon detection design, constructive aspects and the first
Cherenkov light in the detector.Comment: Proceedings of the Imaging 2006 conference, Stockholm, Sweden, 27-30
June 2006, 5 pages, 6 figures, to appear in NIM A; corrected typo in caption
of Fig.
Fast photon detection for the COMPASS RICH detector
The COMPASS experiment at the SPS accelerator at CERN uses a large scale Ring
Imaging CHerenkov detector (RICH) to identify pions, kaons and protons in a
wide momentum range. For the data taking in 2006, the COMPASS RICH has been
upgraded in the central photon detection area (25% of the surface) with a new
technology to detect Cherenkov photons at very high count rates of several 10^6
per second and channel and a new dead-time free read-out system, which allows
trigger rates up to 100 kHz. The Cherenkov photons are detected by an array of
576 visible and ultra-violet sensitive multi-anode photomultipliers with 16
channels each. The upgraded detector showed an excellent performance during the
2006 data taking.Comment: Proceeding of the IPRD06 conference (Siena, Okt. 06
The Fast Read-out System for the MAPMTs of COMPASS RICH-1
A fast readout system for the upgrade of the COMPASS RICH detector has been
developed and successfully used for data taking in 2006 and 2007. The new
readout system for the multi-anode PMTs in the central part of the photon
detector of the RICH is based on the high-sensitivity MAD4
preamplifier-discriminator and the dead-time free F1-TDC chip characterized by
high-resolution. The readout electronics has been designed taking into account
the high photon flux in the central part of the detector and the requirement to
run at high trigger rates of up to 100 kHz with negligible dead-time. The
system is designed as a very compact setup and is mounted directly behind the
multi-anode photomultipliers. The data are digitized on the frontend boards and
transferred via optical links to the readout system. The read-out electronics
system is described in detail together with its measured performances.Comment: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor
change
Influence of environment on the corrosion of glassâmetal connections
'Glass sensors' of the eighteenth century Backer glass and the sixteenth century enamel from Limoges have been chosen for a series of experiments. Combinations of these materials with different base materials such as copper and bronze has been investigated. To create surface changes on the 'glass sensor', a corrosion process was induced in a controlled environment. A variety of corrosive agents such as hydrochloric acid, sulfuric acid, water and formaldehyde were used. The sample immersed in the corrosive solution was exposed alternately to light and high temperature for a total of 38 weeks. During this period, macroscopic and microscopic observations were made and series of tests such as SEM/EDS and Raman spectroscopy were performed on the surface of the samples. ICP-MS methods were used to determine the change in the chemical composition of the solutions where the samples had corroded. The primary aim of this study was to identify the impact of a number of external corrosive variables such as temperature, humidity and local environment to identify the most damaging environments for glassâmetal objects. The obtained results showed the chemical and physical phenomena acting on the surface of the glass, metal or in the place of their joints. Information obtained on this study was used to explain the influence of the environment on the surface of glassâmetal materials. Results can be used in the design of conservation work as well as for sustainable conservation
Reconstruction of the gravitational wave signal during the Virgo science runs and independent validation with a photon calibrator
The Virgo detector is a kilometer-scale interferometer for gravitational wave
detection located near Pisa (Italy). About 13 months of data were accumulated
during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and
September 2011, with increasing sensitivity.
In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the
gravitational wave strain time series from the detector signals is
described. The standard consistency checks of the reconstruction are discussed
and used to estimate the systematic uncertainties of the signal as a
function of frequency. Finally, an independent setup, the photon calibrator, is
described and used to validate the reconstructed signal and the
associated uncertainties.
The uncertainties of the time series are estimated to be 8% in
amplitude. The uncertainty of the phase of is 50 mrad at 10 Hz with a
frequency dependence following a delay of 8 s at high frequency. A bias
lower than and depending on the sky direction of the GW is
also present.Comment: 35 pages, 16 figures. Accepted by CQ
Calibration and sensitivity of the Virgo detector during its second science run
The Virgo detector is a kilometer-length interferometer for gravitational
wave detection located near Pisa (Italy). During its second science run (VSR2)
in 2009, six months of data were accumulated with a sensitivity close to its
design. In this paper, the methods used to determine the parameters for
sensitivity estimation and gravitational wave reconstruction are described. The
main quantities to be calibrated are the frequency response of the mirror
actuation and the sensing of the output power. Focus is also put on their
absolute timing. The monitoring of the calibration data as well as the
parameter estimation with independent techniques are discussed to provide an
estimation of the calibration uncertainties. Finally, the estimation of the
Virgo sensitivity in the frequency-domain is described and typical
sensitivities measured during VSR2 are shown.Comment: 30 pages, 23 figures, 1 table. Published in Classical and Quantum
Gravity (CQG), Corrigendum include
Virgo calibration and reconstruction of the gravitational wave strain during VSR1
Virgo is a kilometer-length interferometer for gravitational waves detection
located near Pisa. Its first science run, VSR1, occured from May to October
2007. The aims of the calibration are to measure the detector sensitivity and
to reconstruct the time series of the gravitational wave strain h(t). The
absolute length calibration is based on an original non-linear reconstruction
of the differential arm length variations in free swinging Michelson
configurations. It uses the laser wavelength as length standard. This method is
used to calibrate the frequency dependent response of the Virgo mirror
actuators and derive the detector in-loop response and sensitivity within ~5%.
The principle of the strain reconstruction is highlighted and the h(t)
systematic errors are estimated. A photon calibrator is used to check the sign
of h(t). The reconstructed h(t) during VSR1 is valid from 10 Hz up to 10 kHz
with systematic errors estimated to 6% in amplitude. The phase error is
estimated to be 70 mrad below 1.9 kHz and 6 micro-seconds above.Comment: 8 pages, 8 figures, proceedings of Amaldi 8 conference, to be
published in Journal of Physics Conference Series (JPCS). Second release:
correct typo
The Polarised Valence Quark Distribution from semi-inclusive DIS
The semi-inclusive difference asymmetry A^{h^{+}-h^{-}} for hadrons of
opposite charge has been measured by the COMPASS experiment at CERN. The data
were collected in the years 2002-2004 using a 160 GeV polarised muon beam
scattered off a large polarised ^6LiD target and cover the range 0.006 < x <
0.7 and 1 < Q^2 < 100 (GeV/c)^2. In leading order QCD (LO) the asymmetry
A_d^{h^{+}-h^{-}} measures the valence quark polarisation and provides an
evaluation of the first moment of Delta u_v + Delta d_v which is found to be
equal to 0.40 +- 0.07 (stat.) +- 0.05 (syst.) over the measured range of x at
Q^2 = 10 (GeV/c)^2. When combined with the first moment of g_1^d previously
measured on the same data, this result favours a non-symmetric polarisation of
light quarks Delta u-bar = - Delta d-bar at a confidence level of two standard
deviations, in contrast to the often assumed symmetric scenario Delta u-bar =
Delta d-bar = Delta s-bar = Delta s.Comment: 7 pages, 3 figures, COMPASS, revised: details added, author list
update
- âŠ