111 research outputs found

    Chemical stability of active ingredients in diluted veterinary disinfectant solutions under simulated storage conditions

    Get PDF
    Introduction: The product labels of veterinary disinfectants specify their expiration dates to prevent the use of outdated products, as these may result in disinfection and biosecurity failures during outbreak situations. However, a clear standard for the storage conditions of diluted disinfectant solutions has not yet been established, and the effects of storage conditions have scarcely been investigated. To fill this research gap, our study examined the stability of the active ingredients of diluted veterinary disinfectants based on their change in concentrations when stored at various temperatures for various time periods.Methods: Twenty veterinary disinfectants effective against either foot-and-mouth disease or avian influenza viruses were selected. The disinfectants were diluted to effective concentrations following the manufacturer’s instructions. Using selective analytical techniques, the concentrations of the active ingredients of the samples that had been stored for varying intervals at different temperatures (4, 20, 30, and 45°C) were determined. These samples included soaps and detergents, acids, oxidizing agents, aldehydes, and copper compounds. The active ingredient concentrations of two of the samples were determined following freezing/thawing cycle, to establish their stability when exposed to simulated winter conditions.Results: Our results showed that most of the active ingredients had concentrations of 90% or greater of their initial concentrations, indicating ≥90% stability over a 21-day period under the experimental storage conditions. However, there were some exceptions. Glutaraldehyde, formaldehyde, and malic acid are over 90% stable at ≤ 30°C for 21 days, but their concentrations decreased to below 90% of their initial concentrations at 45°C, indicating a decline in stability when stored at 45°C for 21 days. The concentrations of potassium peroxymonosulfate and peracetic acid rapidly declined with increasing time and temperature to less than 90% of their initial concentrations.Discussion: Based on our findings, we propose that diluted disinfectant solutions should preferably be prepared daily. However, if the daily preparation of a diluted disinfectant solution is not feasible, then our results can be used as a reference, providing basic scientific data on the chemical stability of diluted disinfectant solutions commonly used in the veterinary field, thus indicating suitable storage conditions

    Superior patient survival for continuous ambulatory peritoneal dialysis patients treated with a peritoneal dialysis fluid with neutral pH and low glucose degradation product concentration (Balance)

    Get PDF
    BACKGROUND: In recent years, laboratory and clinical research has suggested the need for peritoneal dialysis fluids (PDFs) that are more biocompatible than the conventional PDFs commonly used today. Bioincompatibility of PDF has been attributed to low pH, lactate, glucose, glucose degradation products (GDPs), and osmolality. PDFs with neutral pH and low GDPs are now available commercially. In vitro and early clinical studies suggest that these solutions are indeed more biocompatible but, as of now, there is no evidence that their use improves patient outcome. METHODS: Using a dedicated database of over 2000 patients treated with PD in Korea, we were able to conduct a retrospective observational study comparing outcomes for incident continuous ambulatory PD patients treated with a standard, conventional, heat-sterilized PDF to the outcomes for patients treated with a novel, low GDP, neutral-pH PDF prepared in a dual-compartment, double-bag PD system (Balance; Fresenius Medical Care, St. Wendel, Germany). In an intention-to-treat analysis, patient and technique survival, peritonitis-free survival, and peritonitis rates were compared in 611 patients treated with Balance for up to 30 months and 551 patients with a standard PDF (stay . safe; Fresenius Medical Care) treated in the same era and with equivalent follow-up. RESULTS: The patients were well matched for most relevant characteristics except older age distribution for the patients treated with the standard PDF. Patients treated with Balance had significantly superior survival compared to those treated with the standard PDF (74% vs 62% at 28 months, p = 0.0032). In a multivariate Cox regression model including age, diabetes, and gender, the survival advantage persisted (relative risk of death for Balance 0.75, 95% confidence interval 0.56 - 0.99, p = 0.0465). Modality technique survival was similarin Kaplan-Meieranalysis for both PDFs. No differences were detected in peritonitis-free survival or in peritonitis rates between the two solutions. CONCLUSION: This study, for the first time, suggests that treatment with a novel biocompatible PDF with low GDP concentration and neutral pH confers a significant survival advantage. The exact mechanisms for such a survival advantage cannot be determined from this study. The usual criticisms of observational studies apply and the results reported here strongly warrant the undertaking of appropriately designed, randomized, controlled clinical trials

    Efficacy of two different self-expanding nitinol stents for atherosclerotic femoropopliteal arterial disease (SENS-FP trial): study protocol for a randomized controlled trial

    Get PDF
    BACKGROUND: There have been few randomized control trials comparing the incidence of stent fracture and primary patency among different self-expanding nitinol stents to date. The SMART™ CONTROL stent (Cordis Corp, Miami Lakes, Florida, United States) has a peak-to-valley bridge and inline interconnection, whereas the COMPLETE™-SE stent (Medtronic Vascular, Santa Rosa, California, United States) crowns have been configured to minimize crown-to-crown interaction, increasing the stent's flexibility without compromising radial strength. Further, the 2011 ESC (European society of cardiology) guidelines recommend that dual antiplatelet therapy with aspirin and a thienopyridine such as clopidogrel should be administered for at least one month after infrainguinal bare metal stent implantation. Cilostazol has been reported to reduce intimal hyperplasia and subsequent repeat revascularization. To date, there has been no randomized study comparing the safety and efficacy of two different antiplatelet regimens, clopidogrel and cilostazol, following successful femoropopliteal stenting. METHODS/DESIGN: The primary purpose of our study is to examine the incidence of stent fracture and primary patency between two different major representative self-expanding nitinol stents (SMART™ CONTROL versus COMPLETE™-SE) in stenotic or occlusive femoropopliteal arterial lesion. The secondary purpose is to examine whether there is any difference in efficacy and safety between aspirin plus clopidogrel versus aspirin plus cilostazol for one month following stent implantation in femoropopliteal lesions. This is a prospective, randomized, multicenter trial to assess the efficacy of the COMPLETE™-SE versus SMART™ CONTROL stent for provisional stenting after balloon angioplasty in femoropopliteal arterial lesions. The study design is a 2x2 randomization design and a total of 346 patients will be enrolled. The primary endpoint of this study is the rate of binary restenosis in the treated segment at 12 months after intervention as determined by catheter angiography or duplex ultrasound. DISCUSSION: This trial will provide powerful insight into whether the design of the COMPLETE™-SE stent is more fracture-resistant or effective in preventing restenosis compared with the SMART™ CONTROL stent. Also, it will determine the efficacy and safety of aspirin plus clopidogrel versus aspirin plus cilostazol in patients undergoing stent implantation in femoropopliteal lesions. TRIAL REGISTRATION: Registered on 2 April 2012 with the National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier# NCT01570803)

    2D Materials-based platforms for electroanalysis applications

    Get PDF
    A new class of nanomaterials called "2D materials" (2DMs) is attracting recently the electrochemical sensing field due to the unique physicochemical properties associated to their chemical structure, formed by ultra-thin layers. In this review, we summarize the recent advances in the electroanalysis area using 2DMs giving first a brief overview on the structure, synthesis and properties of these materials followed by the analysis of their advantages while used in the development of electrochemical sensors

    ATOMS : ALMA Three-millimeter Observations of Massive Star-forming regions - I. Survey description and a first look at G9.62+0.19

    Get PDF
    The ATOMS, standing for ALMA Three-millimeter Observations of Massive Star-forming regions, survey has observed 146 active star-forming regions with ALMA band 3, aiming to systematically investigate the spatial distribution of various dense gas tracers in a large sample of Galactic massive clumps, to study the roles of stellar feedback in star formation, and to characterize filamentary structures inside massive clumps. In this work, the observations, data analysis, and example science of the ATOMS survey are presented, using a case study for the G9.62+0.19 complex. Toward this source, some transitions, commonly assumed to trace dense gas, including CS J = 2-1, HCO+ J = 1-0, and HCN J = 1-0, are found to show extended gas emission in low-density regions within the clump; less than 25 per cent of their emission is from dense cores. SO, CH3OH, (HCN)-C-13, and HC3N show similar morphologies in their spatial distributions and reveal well the dense cores. Widespread narrow SiO emission is present (over similar to 1 pc), which may be caused by slow shocks from large-scale colliding flows or HII regions. Stellar feedback from an expanding HII region has greatly reshaped the natal clump, significantly changed the spatial distribution of gas, and may also account for the sequential high-mass star formation in the G9.62+0.19 complex. The ATOMS survey data can be jointly analysed with other survey data, e.g. MALT90, Orion B, EMPIRE, ALMA IMF, and ALMAGAL, to deepen our understandings of 'dense gas' star formation scaling relations and massive protocluster formation.Peer reviewe

    ATOMS : ALMA three-millimeter observations of massive star-forming regions - II. Compact objects in ACA observations and star formation scaling relations

    Get PDF
    We report studies of the relationships between the total bolometric luminosity (L-bol or L-TIR) and the molecular line luminosities of J = 1 - 0 transitions of (HCN)-C-13, (HCO+)-C-13, HCN, and HCO+ with data obtained from ACA observations in the 'ATOMS' survey of 146 active Galactic star-forming regions. The correlations between L-bol and molecular line luminosities L-mol' of the four transitions all appear to be approximately linear. Line emission of isotopologues shows as large scatters in L-bol-L-mol' relations as their main line emission. The log(L-bol/L-mol') for different molecular line tracers have similar distributions. The L-bol-to-L-mol' ratios do not change with galactocentric distances (R-GC) and clump masses (M-clump). The molecular line luminosity ratios (HCN-to-HCO+, (HCN)-C-13-to-(HCO+)-C-13, HCN-to-(HCN)-C-13, and HCO+-to-(HCO+)-C-13) all appear constant against L-bol, dust temperature (T-d), M-clump, and R-GC. Our studies suggest that both the main lines and isotopologue lines are good tracers of the total masses of dense gas in Galactic molecular clumps. The large optical depths of main lines do not affect the interpretation of the slopes in star formation relations. We find that the mean star formation efficiency (SFE) of massive Galactic clumps in the 'ATOMS' survey is reasonably consistent with other measures of the SFE for dense gas, even those using very different tracers or examining very different spatial scales.Peer reviewe

    ATOMS : ALMA three-millimeter observations of massive star-forming regions - III. Catalogues of candidate hot molecular cores and hyper/ultra compact H II regions

    Get PDF
    A correction has been published: Monthly Notices of the Royal Astronomical Society, Volume 511, Issue 1, March 2022, Pages 501–505, https://doi.org/10.1093/mnras/stac039We have identified 453 compact dense cores in 3mm continuum emission maps in the ALMA Three-millimetre Observations of Massive Star-forming regions survey, and compiled three catalogues of high-mass star-forming cores. One catalogue, referred to as hyper/ultra compact (H/UC)-HII catalogue, includes 89 cores that enshroud H/UC HII regions as characterized by associated compact H40 alpha emission. A second catalogue, referred to as pure s-cHMC, includes 32 candidate hot molecular cores (HMCs) showing rich spectra (N >= 20 lines) of complex organic molecules (COMs) and not associated with H/UC-HII regions. The third catalogue, referred to as pure w-cHMC, includes 58 candidate HMCs with relatively low levels of COM richness and not associated with H/UC-Hii regions. These three catalogues of dense cores provide an important foundation for future studies of the early stages of high-mass star formation across the Milky Way. We also find that nearly half of H/UC-HII cores are candidate HMCs. From the number counts of COM-containing and H/UC-HII cores, we suggest that the duration of high-mass protostellar cores showing chemically rich features is at least comparable to the lifetime of H/UC-HII regions. For cores in the H/UC-HII catalogue, the width of the H40 alpha line increases as the core size decreases, suggesting that the non-thermal dynamical and/or pressure line-broadening mechanisms dominate on the smaller scales of the H/UC-HII cores.Peer reviewe
    corecore