14 research outputs found

    Formulation and taste masking of ranitidine orally disintegrating tablet

    No full text
    Orally Disintegrating Tablets (ODT) have the advantages of both solid dosage form specially the stability and ease of handling and liquid dosage forms including ease of swallowing and pre-gastric absorption. We focused on taste masking and formulation of ranitidine ODT which disintegrates rapidly in the mouth within 60 sec using super-disintegrants, special polymers, water soluble and even insoluble excipients, sweeteners and essence. Various formulations were designed and made in four series. The amount of ranitidine in each formulation was 150 mg, and the final weight of tablets was around 500 mg. Prepared formulations were evaluated in terms of several physicochemical tests including powder/granule flowability, appearance, thickness, uniformity of weight, hardness, friability and disintegration time. Several taste masking techniques were investigated in each series of formulation, in order to cover the bitter taste of wranitidine. These included the addition of sweetener, granulation, solid dispersion with soluble and insoluble agents and complex formation with cellulose derivatives. The best formulation(s) in each group was/were chosen for taste evaluations with the help of 10 volunteers. Finally, formulation F14 was selected as the ultimate formulation, based on its better taste and shorter disintegration time (around 5 seconds). Formulation F14 contained Na CMC, avicel, Na starch glycolate, xylitol, saccharin, Na benzoate and menthol. The chosen formulation successfully passed the complementary evaluations such as assay of active ingredient and dissolution time. Na CMC was found to be acceptable in terms of decreasing disintegration time and enhanced taste masking potential and can be used in further ODT formulations. © 2016 by School of Pharmacy

    Development and application of a High-Resolution mass spectrometry method for the detection of fentanyl analogs in urine and serum.

    No full text
    IntroductionThe use of illicitly manufactured synthetic opioids, specifically fentanyl and its analogs, has escalated exponentially in the United States over the last decade. Due to the targeted nature of drug detection methods in clinical laboratories and the ever-evolving list of synthetic opioids of concern, alternative analytical approaches are needed.MethodsUsing the fentanyl analog screening (FAS) kit produced by the Centers for Disease Control and Prevention (CDC), we developed a liquid chromatography-high resolution mass spectrometry (LC-HRMS) synthetic opioid spectral library and data acquisition method using information dependent acquisition of product ion spectra. Chromatographic retention times, limits of detection and matrix effects, in urine and serum, for the synthetic opioids in the FAS kit (n = 150) were established. All urine and serum specimens sent to a clinical toxicology laboratory for comprehensive drug testing in 2019 (n = 856) and 2021 (n = 878) were analyzed with the FAS LC-HRMS library to determine the prevalence of fentanyl analogs and other synthetic opioids, retrospectively (2019) and prospectively (2021).ResultsThe limit of detection (LOD) of each opioid ranged from 1 to 10 ng/mL (median, 2.5 ng/mL) in urine and 0.25-2.5 ng/mL (median, 0.5 ng/mL) in serum. Matrix effects ranged from -79 % to 86 % (median, -37 %) for urine, following dilution and direct analysis, and -80 % to 400 % (median, 0 %) for serum, following protein precipitation. The prevalence of fentanyl/fentanyl analogs in serum samples increased slightly from 2019 to 2021 while it remained the same in urine. There were only 2 samples identified that contained a fentanyl analog without the co-occurrence of fentanyl or fentanyl metabolites. Analysis of the established MS/MS spectral library revealed characteristic fragmentation patterns in most fentanyl analogs, which can be used for structure elucidation and drug identification of future analogs.ConclusionsThe LC-HRMS method was capable of detecting fentanyl analogs in routine samples sent for comprehensive drug testing. The method can be adapted to accommodate testing needs for the evolving opioid epidemic

    Health risk assessment of aflatoxin M1 in infant formula milk in IR Iran

    No full text
    In this study, two accurate, precise, selective and sensitive methods were developed for determining aflatoxin M1 (AFM1) in infant formula milk using immunoaffinity column clean-up followed by high performance liquid chromatography (HPLC) with fluorescence detection. The validated methods were used for determination of AFM1 in 29 samples of 6 different infant formula milk brands and the risk of AFM1 in infants aged zero to 6 months old was assessed using cancer risk, Margin of Exposure (MOE) and Hazard Index (HI). Only one sample (3.4) was contaminated with AFM1. Although the results showed that MOE values for the mean and median exposure to AFM1 was <10,000 in infants, the additional cancer risk due to mean and median exposure to AFM1 in infant <6 months were 0.00010 and 0.00012 additional cases per year per 105 individuals, respectively, which indicates no health concern. In addition, HI values for the mean and median exposure to AFM1 for infants were quite below one which indicates no health concern. To the best of our knowledge, this is the first report on risk assessment of AFM1 in infant formula milk consumed by Iranian infants <6 months old, presenting a low risk for the evaluated groups. © 2020 Elsevier Lt
    corecore