Using Satellite Observations to Evaluate Model Microphysical Representation of Arctic Mixed-Phase Clouds
publishedVersio
Superficial Soft-Tissue Sarcomas Rarely Require Advanced Soft-Tissue Reconstruction Following Resection
Objective: Soft-tissue sarcomas are most frequently located deep within myofascial compartments. Superficial soft-tissue sarcomas (S-STS) are relatively less common and may be managed differently than deep sarcomas because generous resection margins are often possible without sacrificing critical structures. We sought to investigate the frequency and types of soft-tissue reconstructive procedures that are required following excision of S-STS.
Methods: We reviewed 457 consecutively treated patients with S-STS with a minimum 2-year follow-up from our prospectively maintained database between 1989 and 2009.
Results: Mean follow-up was 10.5 years (range, 2â23). Four hundred twenty-one tumors (91%) were excised with negative margins, 38 (8.3%) had microscopically positive margins, and three (0.7%) had grossly positive margins. One patient required an amputation. In 271 (58%) patients, the wounds were closed primarily. In comparison, 93 patients (20%) required a rotation flap, 70 (15%) required a split-thickness skin graft, and 23 (5%) underwent a free tissue transfer (ie, advanced reconstructive procedure). The overall complication rate was 12%, although 43% of patients undergoing free tissue transfer developed complications (P = 0.04). An unplanned excision before referral to our center was a risk factor for local recurrence (P = 0.03) when residual tumor was recovered in the reexcision specimen pathologically.
Conclusions: Although concern about the morbidity associated with a free tissue transfer (ie, advanced reconstructive procedure) may potentially limit the adequacy of resection in some patients with S-STS, the results of this study showed that the majority of patients had complete excisions with negative margins and primary closure. Obtaining a negative margin when excising a known or suspected S-STS rarely requires an advanced reconstructive procedure and almost never results in loss of limb
Redox Responses in Patients with Sepsis: High Correlation of Thioredoxin-1 and Macrophage Migration Inhibitory Factor Plasma Levels
Background. Redox active substances (e.g., Thioredoxin-1, Macrophage Migration Inhibitory Factor) seem to be central hubs in the septic inflammatory process.
Materials and Methods. Blood samples from patients with severe sepsis or septic shock (n = 15) were collected at the time of sepsis diagnosis (t0), and 24 (t24) and 48 (t48) hours later; samples from healthy volunteers (n = 18) were collected once; samples from postoperative patients (n = 28) were taken one time immediately after surgery. In all patients, we measured plasma levels of IL-6, TRX1 and MIF.
Results. The plasma levels of MIF and TRX1 were significantly elevated in patients with severe sepsis or septic shock. Furthermore, TRX1 and MIF plasma levels showed a strong correlation (t0: rsp = 0.720, Ï = 0.698/t24: rsp = 0.771, Ï = 0.949).
Conclusions. Proinflammatory/~oxidative and anti-inflammatory/~oxidative agents show a high correlation in order to maintain a redox homeostasis and to avoid the harmful effects of an excessive inflammatory/oxidative response
Next-generation sequencing diagnostics of bacteremia in septic patients
Background: Bloodstream infections remain one of the major challenges in intensive care units, leading to sepsis or even septic shock in many cases. Due to the lack of timely diagnostic approaches with sufficient sensitivity, mortality rates of sepsis are still unacceptably high. However a prompt diagnosis of the causative microorganism is critical to significantly improve outcome of bloodstream infections. Although various targeted molecular tests for blood samples are available, time-consuming blood culture-based approaches still represent the standard of care for the identification of bacteria. Methods: Here we describe the establishment of a complete diagnostic workflow for the identification of infectious microorganisms from seven septic patients based on unbiased sequence analyses of free circulating DNA from plasma by next-generation sequencing. Results: We found significant levels of DNA fragments derived from pathogenic bacteria in samples from septic patients. Quantitative evaluation of normalized read counts and introduction of a sepsis indicating quantifier (SIQ) score allowed for an unambiguous identification of Gram-positive as well as Gram-negative bacteria that exactly matched with blood cultures from corresponding patient samples. In addition, we also identified species from samples where blood cultures were negative. Reads of non-human origin also comprised fragments derived from antimicrobial resistance genes, showing that, in principle, prediction of specific types of resistance might be possible. Conclusions: The complete workflow from sample preparation to species identification report could be accomplished in roughly 30Â h, thus making this approach a promising diagnostic platform for critically ill patients suffering from bloodstream infections
Search for Branons at LEP
We search, in the context of extra-dimension scenarios, for the possible
existence of brane fluctuations, called branons. Events with a single photon or
a single Z-boson and missing energy and momentum collected with the L3 detector
in e^+ e^- collisions at centre-of-mass energies sqrt{s}=189-209$ GeV are
analysed. No excess over the Standard Model expectations is found and a lower
limit at 95% confidence level of 103 GeV is derived for the mass of branons,
for a scenario with small brane tensions. Alternatively, under the assumption
of a light branon, brane tensions below 180 GeV are excluded
Search for Heavy Isosinglet Neutrino in e+e- Annihilation at LEP
We report on a search for the first generation heavy neutrino that is an
isosinglet under the standard SU(2)_L gauge group. The data collected with the
L3 detector at center-of-mass energies between 130 GeV and 208 GeV are used.The
decay channel N_e --> eW is investigated and no evidence is found for a heavy
neutrino, N_e, in a mass range between 80 GeV and 205 GeV. Upper limits on the
mixing parameter between the heavy and light neutrino are derived
Search for Charginos with a Small Mass Difference with the Lightest Supersymmetric Particle at \sqrt{s} = 189 GeV
A search for charginos nearly mass-degenerate with the lightest
supersymmetric particle is performed using the 176 pb^-1 of data collected at
189 GeV in 1998 with the L3 detector. Mass differences between the chargino and
the lightest supersymmetric particle below 4 GeV are considered. The presence
of a high transverse momentum photon is required to single out the signal from
the photon-photon interaction background. No evidence for charginos is found
and upper limits on the cross section for chargino pair production are set. For
the first time, in the case of heavy scalar leptons, chargino mass limits are
obtained for any \tilde{\chi}^{+-}_1 - \tilde{\chi}^0_1 mass difference
Search for Branons at LEP
We search, in the context of extra-dimension scenarios, for the possible
existence of brane fluctuations, called branons. Events with a single photon or
a single Z-boson and missing energy and momentum collected with the L3 detector
in e^+ e^- collisions at centre-of-mass energies sqrt{s}=189-209$ GeV are
analysed. No excess over the Standard Model expectations is found and a lower
limit at 95% confidence level of 103 GeV is derived for the mass of branons,
for a scenario with small brane tensions. Alternatively, under the assumption
of a light branon, brane tensions below 180 GeV are excluded
Measurement of Exclusive rho^0 rho^0 Production in Two-Photon Collisions at High Q^2 at LEP
Exclusive rho rho production in two-photon collisions involving a single
highly virtual photon is studied with data collected at LEP at centre-of-mass
energies 89GeV < \sqrt{s} < 209GeV with a total integrated luminosity of
854.7pb^-1 The cross section of the process gamma gamma^* -> rho rho is
determined as a function of the photon virtuality, Q^2 and the two-photon
centre-of-mass energy, Wgg, in the kinematic region: 1.2GeV^2 < Q^2 < 30GeV^2
and 1.1GeV < Wgg < 3GeV
- âŠ