    Antithrombotic therapy in patients undergoing TAVI: An overview of Dutch hospitals

    Get PDF
    Purpose To assess current antithrombotic treatment strategies in the Netherlands in patients undergoing transcatheter aortic valve implantation (TAVI). Methods For every Dutch hospital performing TAVI (n =14) an interventional cardiologist experienced in performing TAVI was interviewed concerning heparin, aspirin, thienopyridine and oral anticoagulation treatment in patients undergoing TAVI. Results The response rate was 100 %. In every centre, a protocol for antithrombotic treatment after TAVI was available. Aspirin was prescribed in all centres, concomitant clopidogrel was prescribed 13 of the 14 centres. Duration of concomitant clopidogrel was 3 months in over twothirds of cases. In 2 centres, duration of concomitant clopidogrel was based upon type of prosthesis: 6 months versus 3 months for supra-annular and intra-annular prostheses, respectively. Conclusions Leaning on a small basis of evidence and recommendations, the antithrombotic policy for patients undergoing TAVI is highly variable in the Netherlands. As a standardised regimen might further reduce haemorrhagic complications, large randomised clinical trials may help to establish the most appropriate approach

    Filter-based cerebral embolic protection with transcatheter aortic valve implantation: the randomised MISTRAL-C trial

    No full text
    Our aim was to determine whether use of the filter-based Sentinel™ Cerebral Protection System (CPS) during transcatheter aortic valve implantation (TAVI) can affect the early incidence of new brain lesions, as assessed by diffusion-weighted magnetic resonance imaging (DW-MRI), and neurocognitive performance. From January 2013 to July 2015, 65 patients were randomised 1:1 to transfemoral TAVI with or without the Sentinel CPS. Patients underwent DW-MRI and extensive neurological examination, including neurocognitive testing one day before and five to seven days after TAVI. Follow-up DW-MRI and neurocognitive testing was completed in 57% and 80%, respectively. New brain lesions were found in 78% of patients with follow-up MRI. Patients with the Sentinel CPS had numerically fewer new lesions and a smaller total lesion volume (95 mm3 [IQR 10-257] vs. 197 mm3 [95-525]). Overall, 27% of Sentinel CPS patients and 13% of control patients had no new lesions. Ten or more new brain lesions were found only in the control cohort (in 20% vs. 0% in the Sentinel CPS cohort, p=0.03). Neurocognitive deterioration was present in 4% of patients with Sentinel CPS vs. 27% of patients without (p=0.017). The filters captured debris in all patients with Sentinel CPS protection. Filter-based embolic protection captures debris en route to the brain in all patients undergoing TAVI. This study suggests that its use can lead to fewer and overall smaller new brain lesions, as assessed by MRI, and preservation of neurocognitive performance early after TAVI. Dutch trial register-ID: NTR4236. URL http://www.trialregister.nl/trialreg/admin/rctsearch.asp?Term=mistra

    Filter-based cerebral embolic protection with transcatheter aortic valve implantation:the randomised MISTRAL-C trial

    No full text
    Aims: Our aim was to determine whether use of the filter-based Sentinel (TM) Cerebral Protection System (CPS) during transcatheter aortic valve implantation (TAVI) can affect the early incidence of new brain lesions, as assessed by diffusion-weighted magnetic resonance imaging (DW-MRI), and neurocognitive performance. Methods and results: From January 2013 to July 2015, 65 patients were randomised 1:1 to transfemoral TAVI with or without the Sentinel CPS. Patients underwent DW-MRI and extensive neurological examination, including neurocognitive testing one day before and five to seven days after TAVI. Follow-up DW-MRI and neurocognitive testing was completed in 57% and 80%, respectively. New brain lesions were found in 78% of patients with follow-up MRI. Patients with the Sentinel CPS had numerically fewer new lesions and a smaller total lesion volume (95 mm(3) [IQR 10-257] vs. 197 mm(3) [95-525]). Overall, 27% of Sentinel CPS patients and 13% of control patients had no new lesions. Ten or more new brain lesions were found only in the control cohort (in 20% vs. 0% in the Sentinel CPS cohort, p=0.03). Neurocognitive deterioration was present in 4% of patients with Sentinel CPS vs. 27% of patients without (p=0.017). The filters captured debris in all patients with Sentinel CPS protection. Conclusions: Filter-based embolic protection captures debris en route to the brain in all patients undergoing TAVI. This study suggests that its use can lead to fewer and overall smaller new brain lesions, as assessed by MRI, and preservation of neurocognitive performance early after TAVI. Clinical Trial Registration: Dutch trial register-ID: NTR4236. URL http://www.trialregister.nl/trialreg/admin/rctsearch.asp?Term=mistra

    Cognitive and radiological effects of radiotherapy in patients with low-grade glioma: long-term follow-up

    No full text
    Background Our previous study on cognitive functioning among 195 patients with low-grade glioma (LGG) a mean of 6 years after diagnosis suggested that the tumour itself, rather than the radiotherapy used to treat it, has the most deleterious effect on cognitive functioning; only high fraction dose radiotherapy (>2 Gy) resulted in significant added cognitive deterioration. The present study assesses the radiological and cognitive abnormalities in survivors of LGG at a mean of 12 years after first diagnosis. Methods Patients who have had stable disease since the first assessment were invited for follow-up cognitive assessment (letter-Aigit substitution test, concept shifting test, Stroop colour-word test, visual verbal learning test, memory comparison test, and categoric word fluency). Compound scores in six cognitive domains (attention, executive functioning, verbal memory, working memory, psychomotor functioning, and information processing speed) were calculated to detect differences between patients who had radiotherapy and patients who did not have radiotherapy. White-matter hyperintensities and global cortical atrophy were rated on MRI scans. Findings 65 patients completed neuropsychological follow-up at a mean of 12 years (range 6-28 years). 32 (49%) patients had received radiotherapy (three had fraction doses >2 Gy). The patients who had radiotherapy had more deficits that affected attentional functioning at the second follow-up, regardless of fraction dose, than those who did not have radiotherapy (-1.6 [SD 2.41 vs -0.1 [1.3], p=0.003; mean difference 1.4, 95% CI 0.5-2-4). The patients who had radiotherapy also did worse in measures of executive fucntioning (-2.0 [3.7] vs -0.5 [1.2], p=0.03; mean difference 1.5, 0.2-2.9) and information processing speed (-2.0 [3.7] vs -0.6 [1.5], p=0.05; mean difference 0.8, 0.009-1.6]) between the two assessments. Furthermore, attentional. functioning deteriorated significantly between the first and second assessments in patients who had radiotherapy (p=0.25). In total, 17 (53%) patients who had radiotherapy developed cognitive disabilities deficits in at least five of 18 neuropsychological test parameters compared with four (27%) patients who were radiotherapy naive. White-matter hyperintensities and global cortical atrophy were associated with worse cognitive functioning in several domains. Interpretation Long-term survivors of LGG who did not have radiotherapy had stable radiological and cognitive status. By contrast, patients with low-grade glioma who received radiotherapy showed a progressive decline in attentional functioning, even those who received fraction doses that are regarded as safe ( <= 2 Gy). These cognitive deficits are associated with radiological abnormalities. Our results suggest that the risk of long-term cognitive and radiological compromise that is associated with radiotherapy should be considered when treatment is planned. Funding Kaptein Fonds; Schering Ploug