195 research outputs found

    Brillouin amplification in phase coherent transfer of optical frequencies over 480 km fiber

    Full text link
    We describe the use of fiber Brillouin amplification (FBA) for the coherent transmission of optical frequencies over a 480 km long optical fiber link. FBA uses the transmission fiber itself for efficient, bi-directional coherent amplification of weak signals with pump powers around 30 mW. In a test setup we measured the gain and the achievable signal-to-noise ratio (SNR) of FBA and compared it to that of the widely used uni-directional Erbium doped fiber amplifiers (EDFA) and to our recently built bi-directional EDFA. We measured also the phase noise introduced by the FBA and used a new and simple technique to stabilize the frequency of the FBA pump laser. We then transferred a stabilized laser frequency over a wide area network with a total fiber length of 480 km using only one intermediate FBA station. After compensating the noise induced by the fiber, the frequency is delivered to the user end with an uncertainty below 2x10-18 and an instability sigma(tau) = 2x10-14/(tau/second)

    Frequency comparisons and absolute frequency measurements of 171Yb+ single-ion optical frequency standards

    Full text link
    We describe experiments with an optical frequency standard based on a laser cooled 171^{171}Yb+^+ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2S1/2(F=0)^2S_{1/2}(F=0) ground state to the 2D3/2(F=2)^2D_{3/2}(F=2) state at the wavelength of 436 nm is used as the reference transition. In order to compare two 171^{171}Yb+^+ standards, separate frequency servo systems are employed to stabilize two probe laser frequencies to the reference transition line centers of two independently stored ions. The experimental results indicate a relative instability (Allan standard deviation) of the optical frequency difference between the two systems of σy(1000s)=51016\sigma_y(1000 {\rm s})=5\cdot 10^{-16} only, so that shifts in the sub-hertz range can be resolved. Shifts of several hertz are observed if a stationary electric field gradient is superimposed on the radiofrequency trap field. The absolute optical transition frequency of Yb+^+ at 688 THz was measured with a cesium atomic clock at two times separated by 2.8 years. A temporal variation of this frequency can be excluded within a 1σ1\sigma relative uncertainty of 4.410154.4\cdot 10^{-15} yr1^{-1}. Combined with recently published values for the constancy of other transition frequencies this measurement provides a limit on the present variability of the fine structure constant α\alpha at the level of 2.010152.0\cdot 10^{-15} yr1^{-1}.Comment: 12 pages, 5 figures, Proceedings of MPLP'04, Novosibirsk, August 22.-27., 200

    Interrogation of caesium atoms in a fountain clock by a femtosecond laser microwave oscillator

    Full text link
    A caesium fountain clock is operated utilizing a microwave oscillator that derives its frequency stability from a stable laser by means of a fiber-laser femtosecond frequency comb. This oscillator is based on the technology developed for optical clocks and replaces the quartz based microwave oscillator commonly used in fountain clocks. As a result, a significant decrease of the frequency instability of the fountain clock is obtained, reaching 0.74E-14 at 100 s averaging time. We could demonstrate that for a significant range of detected atom numbers the instability is limited by quantum projection noise only, and that for the current status of this fountain clock the new microwave source poses no limit on the achievable frequency instability.Comment: 4 pages, 4 figure

    The optical calcium frequency standards of PTB and NIST

    Get PDF
    We describe the current status of the Ca optical frequency standards with laser-cooled neutral atoms realized in two different laboratories for the purpose of developing a possible future optical atomic clock. Frequency measurements performed at the Physikalisch-Technische Bundesanstalt (PTB) and the National Institute of Standards and Technology (NIST) make the frequency of the clock transition of 40Ca one of the best known optical frequencies (relative uncertainty 1.2e-14) and the measurements of this frequency in both laboratories agree to well within their respective uncertainties. Prospects for improvement by orders of magnitude in the relative uncertainty of the standard look feasible.Comment: 13 pages, 11 figures, to appear in Comptes Rendus Physiqu

    Основні закономірності зародження і росту втомних тріщин в алюмінієвих пластинах із зміцненими отворами

    Get PDF
    The method of modeling stress-strain state for holes burnishing using FEM has been analyzed. A series of fatigue tests were carried out using plates containing plain holes and cold expanded holes in aluminium For various diameters of holes and cold expansion degree there exists a certain correlation between the stress range or maximum stress on the edge of hole on the entrance face of plate and lifetime of fatigue crack initiation

    Interrogation laser for a strontium lattice clock

    Full text link
    We report on the setup and characterization of a 698 nm master-slave diode laser system to probe the 1S0-3P0 clock transition of strontium atoms confined in a one-dimensional optical lattice. A linewidth in the order of around 100 Hz of the laser system has been measured with respect to an ultrastable 657 nm diode laser with 1 Hz linewidth using a femtosecond fiber comb as transfer oscillator. The laser has been used to measure the magnetically induced 1S0-3P0 clock transition in 88Sr where a linewidth of 165 Hz has been observed. The transfer oscillator method provides a virtual beat signal between the two diode lasers that has been used to phase lock the 698 nm laser to the 1 Hz linewidth laser at 657 nm, transferring its stability to the 698 nm laser system.Comment: 5 pages, 7 figures, to be published in "IEEE Transactions on Instrumentation and Measurement, Special Issue CPEM 2008
    corecore