543 research outputs found

    Formation of Chromate Conversion Coatings on Aluminum and Its Alloys

    Get PDF
    In situ X-ray adsorption near-edge structure (XANES) has been used to investigate the formation of chromate conversion coatings on pure Al, commercial Al alloys (AA 1100, AA2024, and AA7075), and a series of binary Al–Cu alloys. The method employed cells designed to determine the growth of the total chromium [Cr(total)] and hexavalent chromate [Cr(VI)] in the chromate conversion coating (CCC) as a function of exposure time to a chromate solution. Three sets of data were obtained, where (i) the Al was exposed to only a limited amount of solution; (ii) the chromate solution was excluded after short periods of repeated exposures to the solution; and (iii) the Al was exposed continuously to the chromate solution. All the results showed a very rapid initial growth within the first seconds, followed by a continued increase in thickness for exposures up to 1 h. Measurements with Al–Cu binary alloys demonstrated that the difference observed in AA2024 and AA1100 may not be due to Cu alloying. The proportion of Cr(VI) in the coatings becomes approximately constant after 180 s of exposure for all the specimens examined, even though the coatings continued to grow

    Health impact of nanotechnologies in food production

    Get PDF
    Geen RIVM rapportnummer in publicatieInventory study on the current use of nanotechnology in food products and advise on the most relevant safety evaluation issues. This report describes the results of this study. The report is set up in two parts. First you will find an aggregation of the results in the answer to 10 questions. In this part you will also find our suggestions for prioritizing the research that is needed. The second document is a scientific background document

    FLAIR-only joint volumetric analysis of brain lesions and atrophy in clinically isolated syndrome (CIS) suggestive of multiple sclerosis

    Get PDF
    Background: MRI assessment in multiple sclerosis (MS) focuses on the presence of typical white matter (WM) lesions. Neurodegeneration characterised by brain atrophy is recognised in the research field as an important prognostic factor. It is not routinely reported clinically, in part due to difficulty in achieving reproducible measurements. Automated MRI quantification of WM lesions and brain volume could provide important clinical monitoring data. In general, lesion quantification relies on both T1 and FLAIR input images, while tissue volumetry relies on T1. However, T1-weighted scans are not routinely included in the clinical MS protocol, limiting the utility of automated quantification. Objectives: We address an aspect of this important translational challenge by assessing the performance of FLAIR-only lesion and brain segmentation, against a conventional approach requiring multi-contrast acquisition. We explore whether FLAIR-only grey matter (GM) segmentation yields more variability in performance compared with two-channel segmentation; whether this is related to field strength; and whether the results meet a level of clinical acceptability demonstrated by the ability to reproduce established biological associations. Methods: We used a multicentre dataset of subjects with a CIS suggestive of MS scanned at 1.5T and 3T in the same week. WM lesions were manually segmented by two raters, ‘manual 1′ guided by consensus reading of CIS-specific lesions and ‘manual 2′ by any WM hyperintensity. An existing brain segmentation method was adapted for FLAIR-only input. Automated segmentation of WM hyperintensity and brain volumes were performed with conventional (T1/T1 + FLAIR) and FLAIR-only methods. Results: WM lesion volumes were comparable at 1.5T between ‘manual 2′ and FLAIR-only methods and at 3T between ‘manual 2′, T1 + FLAIR and FLAIR-only methods. For cortical GM volume, linear regression measures between conventional and FLAIR-only segmentation were high (1.5T: α = 1.029, R2 = 0.997, standard error (SE) = 0.007; 3T: α = 1.019, R2 = 0.998, SE = 0.006). Age-associated change in cortical GM volume was a significant covariate in both T1 (p = 0.001) and FLAIR-only (p = 0.005) methods, confirming the expected relationship between age and GM volume for FLAIR-only segmentations. Conclusions: FLAIR-only automated segmentation of WM lesions and brain volumes were consistent with results obtained through conventional methods and had the ability to demonstrate biological effects in our study population. Imaging protocol harmonisation and validation with other MS phenotypes could facilitate the integration of automated WM lesion volume and brain atrophy analysis as clinical tools in radiological MS reporting

    RHYTHM-AF: design of an international registry on cardioversion of atrial fibrillation and characteristics of participating centers

    Get PDF
    BACKGROUND Atrial fibrillation is a serious public health problem posing a considerable burden to not only patients, but the healthcare environment due to high rates of morbidity, mortality, and medical resource utilization. There are limited data on the variation in treatment practice patterns across different countries, healthcare settings and the associated health outcomes. METHODS/DESIGN RHYTHM-AF was a prospective observational multinational study of management of recent onset atrial fibrillation patients considered for cardioversion designed to collect data on international treatment patterns and short term outcomes related to cardioversion. We present data collected in 10 countries between May 2010 and June 2011. Enrollment was ongoing in Italy and Brazil at the time of data analysis. Data were collected at the time of atrial fibrillation episode in all countries (Australia, Brazil, France, Germany, Italy, Netherlands, Poland, Spain, Sweden, United Kingdom), and cumulative follow-up data were collected at day 60 (±10) in all but Spain. Information on center characteristics, enrollment data, patient demographics, detail of atrial fibrillation episode, medical history, diagnostic procedures, acute treatment of atrial fibrillation, discharge information and the follow-up data on major events and rehospitalizations up to day 60 were collected. DISCUSSIN A total of 3940 patients were enrolled from 175 acute care centers. 70.5% of the centers were either academic (44%) or teaching (26%) hospitals with an overall median capacity of 510 beds. The sites were mostly specialized with anticoagulation clinics (65.9%), heart failure (75.1%) and hypertension clinics (60.1%) available. The RHYTHM-AF registry will provide insight into regional variability of antiarrhythmic and antithrombotic treatment of atrial fibrillation, the appropriateness of such treatments with respect to outcomes, and their cost-efficacy. Observations will help inform strategies to improve cardiovascular outcomes in patients with atrial fibrillation. TRIAL REGISTRATION Clinical trials NCT01119716Harry JGM Crijns, Lori D Bash, François Chazelle, Jean-Yves Le Heuzey, Thorsten Lewalter, Gregory YH Lip, Aldo P Maggioni, Alfonso Martín, Piotr Ponikowski, Mårten Rosenqvist, Prashanthan Sanders, Mauricio Scanavacca, Alexandra A Bernhardt, Sreevalsa Unniachan, Hemant M Phatak and Anselm K Git

    Health impact of nanotechnologies in food production

    Get PDF
    Geen RIVM rapportnummer in publicatieInventory study on the current use of nanotechnology in food products and advise on the most relevant safety evaluation issues. This report describes the results of this study. The report is set up in two parts. First you will find an aggregation of the results in the answer to 10 questions. In this part you will also find our suggestions for prioritizing the research that is needed. The second document is a scientific background document

    The physiological variability of channel density in hippocampal CA1 pyramidal cells and interneurons explored using a unified data-driven modeling workflow

    Get PDF
    Every neuron is part of a network, exerting its function by transforming multiple spatiotemporal synaptic input patterns into a single spiking output. This function is specified by the particular shape and passive electrical properties of the neuronal membrane, and the composition and spatial distribution of ion channels across its processes. For a variety of physiological or pathological reasons, the intrinsic input/output function may change during a neuron’s lifetime. This process results in high variability in the peak specific conductance of ion channels in individual neurons. The mechanisms responsible for this variability are not well understood, although there are clear indications from experiment and modeling that degeneracy and correlation among multiple channels may be involved. Here, we studied this issue in biophysical models of hippocampal CA1 pyramidal neurons and interneurons. Using a unified data-driven simulation workflow and starting from a set of experimental recordings and morphological reconstructions obtained from rats, we built and analyzed several ensembles of morphologically and biophysically accurate single cell models with intrinsic electrophysiological properties consistent with experimental findings. The results suggest that the set of conductances expressed in any given hippocampal neuron may be considered as belonging to two groups: one subset is responsible for the major characteristics of the firing behavior in each population and the other responsible for a robust degeneracy. Analysis of the model neurons suggests several experimentally testable predictions related to the combination and relative proportion of the different conductances that should be expressed on the membrane of different types of neurons for them to fulfill their role in the hippocampus circuitry

    Inventarisatie en heronderzoek van monsters NPK meststoffen in verband met afwijkingen ten opzichte van de gestelde norm

    Get PDF
    I.v.m. geconstateerde afwijkingen van monsters NPK meststoffen t.o.v. de gestelde norm zijn de wettelijk voorgeschreven EEG-methoden voor gehalten aan P2O5, oplosbaar in water, en neutraal ammoniumcitraat op dupliceerbaarheid en op reproduceerbaarheid volgens de Meststoffenwet onderzocht

    Rationale and current perspective for early rhythm control therapy in atrial fibrillation

    Get PDF
    Atrial fibrillation (AF) is the most common sustained arrhythmia and an important source for mortality and morbidity on a population level. Despite the clear association between AF and death, stroke, and other cardiovascular events, there is no evidence that rhythm control treatment improves outcome in AF patients. The poor outcome of rhythm control relates to the severity of the atrial substrate for AF not only due to the underlying atrial remodelling process but also due to the poor efficacy and adverse events of the currently available ion-channel antiarrhythmic drugs and ablation techniques. Data suggest, however, an association between sinus rhythm maintenance and improved survival. Hypothetically, sinus rhythm may also lead to a lower risk of stroke and heart failure. The presence of AF, thus, seems one of the modifiable factors associated with death and cardiovascular morbidity in AF patients. Patients with a short history of AF and the underlying heart disease have not been studied before. It is fair to assume that abolishment of AF in these patients is more successful and possibly also safer, which could translate into a prognostic benefit of early rhythm control therapy. Several trials are now investigating whether aggressive early rhythm control therapy can reduce cardiovascular morbidity and mortality and increase maintenance of sinus rhythm. In the present paper we describe the background of these studies and provide some information on their design

    The heat-pipe resembling action of boiling bubbles in endovenous laser ablation

    Get PDF
    Endovenous laser ablation (EVLA) produces boiling bubbles emerging from pores within the hot fiber tip and traveling over a distal length of about 20 mm before condensing. This evaporation-condensation mechanism makes the vein act like a heat pipe, where very efficient heat transport maintains a constant temperature, the saturation temperature of 100°C, over the volume where these non-condensing bubbles exist. During EVLA the above-mentioned observations indicate that a venous cylindrical volume with a length of about 20 mm is kept at 100°C. Pullback velocities of a few mm/s then cause at least the upper part of the treated vein wall to remain close to 100°C for a time sufficient to cause irreversible injury. In conclusion, we propose that the mechanism of action of boiling bubbles during EVLA is an efficient heat-pipe resembling way of heating of the vein wall

    The Dark Side of EGFP: Defective Polyubiquitination

    Get PDF
    Enhanced Green Fluorescent Protein (EGFP) is the most commonly used live cell reporter despite a number of conflicting reports that it can affect cell physiology. Thus far, the precise mechanism of GFP-associated defects remained unclear. Here we demonstrate that EGFP and EGFP fusion proteins inhibit polyubiquitination, a posttranslational modification that controls a wide variety of cellular processes, like activation of kinase signalling or protein degradation by the proteasome. As a consequence, the NF-κB and JNK signalling pathways are less responsive to activation, and the stability of the p53 tumour suppressor is enhanced in cell lines and in vivo. In view of the emerging role of polyubiquitination in the regulation of numerous cellular processes, the use of EGFP as a live cell reporter should be carefully considered
    corecore