601 research outputs found
Shear effects in lateral piezoresponse force microscopy at 180 ferroelectric domain walls
In studies using piezoresponse force microscopy, we observe a non-zero
lateral piezoresponse at 180 domain walls in out-of-plane polarized,
c-axis-oriented tetragonal ferroelectric Pb(ZrTi)O
epitaxial thin films. We attribute these observations to a shear strain effect
linked to the sign change of the piezoelectric coefficient through the
domain wall, in agreement with theoretical predictions. We show that in
monoclinically distorted tetragonal BiFeO films, this effect is
superimposed on the lateral piezoresponse due to actual in-plane polarization,
and has to be taken into account in order to correctly interpret the
ferroelectric domain configuration.Comment: 4 pages, 3 figure
The DICE calibration project: design, characterization, and first results
We describe the design, operation, and first results of a photometric
calibration project, called DICE (Direct Illumination Calibration Experiment),
aiming at achieving precise instrumental calibration of optical telescopes. The
heart of DICE is an illumination device composed of 24 narrow-spectrum,
high-intensity, light-emitting diodes (LED) chosen to cover the
ultraviolet-to-near-infrared spectral range. It implements a point-like source
placed at a finite distance from the telescope entrance pupil, yielding a flat
field illumination that covers the entire field of view of the imager. The
purpose of this system is to perform a lightweight routine monitoring of the
imager passbands with a precision better than 5 per-mil on the relative
passband normalisations and about 3{\AA} on the filter cutoff positions. The
light source is calibrated on a spectrophotometric bench. As our fundamental
metrology standard, we use a photodiode calibrated at NIST. The radiant
intensity of each beam is mapped, and spectra are measured for each LED. All
measurements are conducted at temperatures ranging from 0{\deg}C to 25{\deg}C
in order to study the temperature dependence of the system. The photometric and
spectroscopic measurements are combined into a model that predicts the spectral
intensity of the source as a function of temperature. We find that the
calibration beams are stable at the level -- after taking the slight
temperature dependence of the LED emission properties into account. We show
that the spectral intensity of the source can be characterised with a precision
of 3{\AA} in wavelength. In flux, we reach an accuracy of about 0.2-0.5%
depending on how we understand the off-diagonal terms of the error budget
affecting the calibration of the NIST photodiode. With a routine 60-mn
calibration program, the apparatus is able to constrain the passbands at the
targeted precision levels.Comment: 25 pages, 27 figures, accepted for publication in A&
The OPERA experiment Target Tracker
The main task of the Target Tracker detector of the long baseline neutrino
oscillation OPERA experiment is to locate in which of the target elementary
constituents, the lead/emulsion bricks, the neutrino interactions have occurred
and also to give calorimetric information about each event. The technology used
consists in walls of two planes of plastic scintillator strips, one per
transverse direction. Wavelength shifting fibres collect the light signal
emitted by the scintillator strips and guide it to both ends where it is read
by multi-anode photomultiplier tubes. All the elements used in the construction
of this detector and its main characteristics are described.Comment: 25 pages, submitted to Nuclear Instrument and Method
Sarcopenia and cognitive impairment in elderly women: results from the EPIDOS cohort
BACKGROUND: common pathophysiological pathways are shared between age-related body composition changes and cognitive impairment.
OBJECTIVE: evaluate whether current operative sarcopenia definitions are associated with cognition in community-dwelling older women.
DESIGN: cross-sectional analyses.
SUBJECTS: a total of 3,025 women aged 75 years and older.
MEASUREMENTS: body composition (assessed by dual energy X-ray absorptiometry) and cognition (measured by short portable mental status questionnaire) were obtained in all participants. Multivariate logistic regression models assessed the association of six operative definitions of sarcopenia with cognitive impairment. Gait speed (GS, measured over a 6-meter track at usual pace) and handgrip strength (HG, measured by a hand-held dynamometer) were considered additional factors of interest.
RESULTS: a total of 492 (16.3%) women were cognitively impaired. The prevalence of sarcopenia ranged from 3.3 to 18.8%. No sarcopenia definition was associated with cognitive impairment after controlling for potential confounders. To proof consistency, the analyses were performed using GS and HG, two well-established predictors of cognitive impairment. Low GS [odds ratio (OR) 2.42, 95% confidence interval (CI) 1.72-3.40] and low HG (OR: 1.81, 95% CI: 1.33-2.46) were associated with cognitive impairment.
CONCLUSION: no significant association was evidenced between different operative sarcopenia definitions and cognitive impairment. The study suggests that the association between physical performance and cognitive impairment in not mediated by sarcopenia
Study of 2b-decay of Mo-100 and Se-82 using the NEMO3 detector
After analysis of 5797 h of data from the detector NEMO3, new limits on
neutrinoless double beta decay of Mo-100 (T_{1/2} > 3.1 10^{23} y, 90% CL) and
Se-82 (T_{1/2} > 1.4 10^{23} y, 90% CL) have been obtained. The corresponding
limits on the effective majorana neutrino mass are: m < (0.8-1.2) eV and m <
(1.5-3.1) eV, respectively. Also the limits on double-beta decay with Majoron
emission are: T_{1/2} > 1.4 10^{22} y (90% CL) for Mo-100 and T_{1/2}> 1.2
10^{22} y (90%CL) for Se-82. Corresponding bounds on the Majoron-neutrino
coupling constant are g < (0.5-0.9) 10^{-4} and < (0.7-1.6) 10^{-4}.
Two-neutrino 2b-decay half-lives have been measured with a high accuracy,
T_{1/2} Mo-100 = [7.68 +- 0.02(stat) +- 0.54(syst) ] 10^{18} y and T_{1/2}
Se-82 = [10.3 +- 0.3(stat) +- 0.7(syst) ] 10^{19} y.Comment: 5 pages, 4 figure
Technical design and performance of the NEMO3 detector
The development of the NEMO3 detector, which is now running in the Frejus
Underground Laboratory (L.S.M. Laboratoire Souterrain de Modane), was begun
more than ten years ago. The NEMO3 detector uses a tracking-calorimeter
technique in order to investigate double beta decay processes for several
isotopes. The technical description of the detector is followed by the
presentation of its performance.Comment: Preprint submitted to Nucl. Instrum. Methods A Corresponding author:
Corinne Augier ([email protected]
Nutrition and dementia care: developing an evidence-based model for nutritional care in nursing homes.
BACKGROUND: There is a growing volume of research to offer improvements in nutritional care for people with dementia living in nursing homes. Whilst a number of interventions have been identified to support food and drink intake, there has been no systematic research to understand the factors for improving nutritional care from the perspectives of all those delivering care in nursing homes. The aim of this study was to develop a research informed model for understanding the complex nutritional problems associated with eating and drinking for people with dementia. METHODS: We conducted nine focus groups and five semi-structured interviews with those involved or who have a level of responsibility for providing food and drink and nutritional care in nursing homes (nurses, care workers, catering assistants, dietitians, speech and language therapists) and family carers. The resulting conceptual model was developed by eliciting care-related processes, thus supporting credibility from the perspective of the end-users. RESULTS: The seven identified domain areas were person-centred nutritional care (the overarching theme); availability of food and drink; tools, resources and environment; relationship to others when eating and drinking; participation in activities; consistency of care and provision of information. CONCLUSIONS: This collaboratively developed, person-centred model can support the design of new education and training tools and be readily translated into existing programmes. Further research is needed to evaluate whether these evidence-informed approaches have been implemented successfully and adopted into practice and policy contexts and can demonstrate effectiveness for people living with dementia
Measurements of daily energy intake and total energy expenditure in people with dementia in care homes: the use of wearable technology.
Objectives: To estimate daily total energy expenditure (TEE) using a physical activity monitor, combined
with dietary assessment of energy intake to assess the relationship between daily energy expenditure and
patterns of activity with energy intake in people with dementia living in care homes. Design and setting:
A cross-sectional study in care homes in the UK. Participants: Twenty residents with confirmed dementia
diagnosis were recruited from two care homes that specialised in dementia care. Measurements: A
physical activity monitor (Sensewear TM Armband , Body Media, Pittsburgh, PA) was employed to
objectively determine total energy expenditure, sleep duration and physical activity. The armband was
placed around the left upper triceps for up to 7 days. Energy intake was determined by weighing all food
and drink items over 4 days (3 weekdays and 1 weekend day) including measurements of food wastage.
Results: The mean age was 78.7 (SD ± 11.8) years, Body Mass Index (BMI) 23.0 (SD ± 4.2) kg/m2
; 50%
were women. Energy intake (mean 7.4; SD ± 2.6) MJ/d) was correlated with TEE (mean 7.6; SD ± 1.8 MJ/d;
r=0.49, p<0.05). Duration of sleeping ranged from 0.4-12.5 (mean 6.1) hrs/d and time spent lying down
was 1.3-16.0 (8.3) hrs/d. On average residents spent 17.9 (6.3-23.4) hrs/d undertaking sedentary activity.
TEE was correlated with BMI (r=0.52, p<0.05) and body weight (r=0.81, p<0.001) but inversely related to
sleep duration (r=-0.59, p<0.01) and time lying down (r=-0.62, p<0.01). Multiple linear regression analysis
revealed that after taking BMI, sleep duration and time spent lying down into account, TEE was no longer
correlated with energy intake. Conclusions: The results show the extent to which body mass, variable
activity and sleep patterns may be contributing to TEE and together with reduced energy intake, energy
requirements were not satisfied. Thus wearable technology has the potential to offer real-time
monitoring to provide appropriate nutrition management that is more person-centred to prevent weight
loss in dementi
Population Pharmacokinetics and Pharmacodynamics Modeling of Torasemide and Furosemide After Oral Repeated Administration in Healthy Dogs
Torasemide is a loop diuretic licensed in dogs for cardiogenic pulmonary oedema. The aim of this pharmacokinetic-pharmacodynamic (PK/PD) study was to define an optimally effective dosage regimen based on preclinical data. In a first study, 5 dogs received once-daily oral torasemide (0, 0.1, 0.2, 0.4, 0.8 mg/kg/day) for 14 days. A second study compared once-daily oral torasemide (0, 0.1, 0.2, 0.3, 0.4 mg/kg/day) to twice-daily furosemide (1, 2, 4, 8 mg/kg/day). For all doses of the second study, 11 dogs received a first day of treatment, followed by a 3 day washout and resumed daily treatment for 10 days (until Day 14). Blood and urine were collected to measure urinary torasemide excretion and plasma torasemide concentrations and daily diuresis and natriuresis. Torasemide PK was linear. After rapid absorption (Tmax 0.5–1 h), 61% of the bioavailable torasemide was eliminated unchanged in urine. Diuresis and natriuresis observed with torasemide were similar to the ones obtained after furosemide (daily dose-ratios: 1/20 to 1/10). The average diuresis increased from baseline (220 ± 53 mL/day for 10 kg dogs) to 730 ±120 mL after the first torasemide administration and up to 1150 ± 252 mL after 10 administrations at the highest dose. At higher doses (≥0.3 mg/kg/day), daily diureses after 10 diuretic treatment-days were higher than Day 1 and variable between dogs; in contrast, diureses remained constant over time and less variable for doses up to 0.2 mg/kg/day. Natriuresis peaked after the first day and decreased dramatically after the 2nd treatment-day then stabilized to a value close to baseline, except for 0.4 mg/kg/day. Urinary torasemide excretion predicted pharmacodynamics better than plasma concentrations. The decrease in natriuresis observed was successfully modeled using a resistance mechanism; this is likely due to a reabsorption of sodium which did not seem however to affect the volume of urine excreted. For a daily target diuresis of 460 mL/dog/day in severe pulmonary oedema (net fluid loss 240 mL/dog/day), a computed dose of 0.26 mg/kg/day (3.5 mg/kg/day furosemide-equivalent) was selected for clinical studies. Due to high inter-individual variability in diureses at doses ≥0.3 mg/kg, higher doses should be limited to 3–5 days to avoid supra-clinical effects in high responders
Cognitive frailty: rational and definition from an (I.A.N.A./I.A.G.G.) international consensus group.
The frailty syndrome has recently attracted attention of the scientific community and public health organizations as precursor and contributor of age-related conditions (particularly disability) in older persons. in parallel, dementia and cognitive disorders also represent major healthcare and social priorities. although physical frailty and cognitive impairment have shown to be related in epidemiological studies, their pathophysiological mechanisms have been usually studied separately. an international Consensus Group on “Cognitive Frailty” was organized by the international academy on nutrition and aging (i.a.n.a) and the international association of Gerontology and Geriatrics (i.a.G.G) on april 16th, 2013 in toulouse (France). the present report describes the results of the Consensus Group and provides the first definition of a “Cognitive Frailty” condition in older adults. specific aim of this approach was to facilitate the design of future personalized preventive interventions in older persons. Finally, the Group discussed the use of multidomain interventions focused on the physical, nutritional, cognitive and psychological domains for improving the well-being and quality of life in the elderly. the consensus panel proposed the identification of the so-called “cognitive frailty” as an heterogeneous clinical manifestation characterized by the simultaneous presence of both physical frailty and cognitive impairment. in particular, the key factors defining such a condition include: 1) presence of physical frailty and cognitive impairment (Cdr=0.5); and 2) exclusion of concurrent ad dementia or other dementias. under different circumstances, cognitive frailty may represent a precursor of neurodegenerative processes. a potential for reversibility may also characterize this entity. a psychological component of the condition is evident and concurs at increasing the vulnerability of the individual to stressors
- …
