139 research outputs found

    Multiresponsive behavior of functional poly(p-phenylene vinylene)s in water

    Get PDF
    The multiresponsive behavior of functionalized water-soluble conjugated polymers (CPs) is presented with potential applications for sensors. In this study, we investigated the aqueous solubility behavior of water-soluble CPs with high photoluminescence and with a particular focus on their pH and temperature responsiveness. For this purpose, two poly(phenylene vinylene)s (PPVs)-namely 2,5-substituted PPVs bearing both carboxylic acid and methoxyoligoethylene glycol units-were investigated, with different amount of carboxylic acid units. Changes in the pH and temperature of polymer solutions led to a response in the fluorescence intensity in a pH range from 3 to 10 and for temperatures ranging from 10 to 85 degrees C. Additionally, it is demonstrated that the polymer with the largest number of carboxylic acid groups displays upper critical solution temperature (UCST)-like thermoresponsive behavior in the presence of a divalent ion like Ca2+. The sensing capability of these water-soluble PPVs could be utilized to design smart materials with multiresponsive behavior in biomedicine and soft materials

    Intrathecal Drug Delivery (ITDD) systems for cancer pain

    Get PDF
    Intrathecal drug delivery is an effective pain management option for patients with chronic and cancer pain. The delivery of drugs into the intrathecal space provides superior analgesia with smaller doses of analgesics to minimize side effects while significantly improving quality of life. This article aims to provide a general overview of the use of intrathecal drug delivery to manage pain, dosing recommendations, potential risks and complications, and growing trends in the field

    Postoperative Pain Management in Children of Hispanic Origin: A Descriptive Cohort Study

    Get PDF
    BACKGROUND: It has been established that pain is frequently undertreated in children following outpatient surgery. Very few studies, however, have investigated this phenomenon in ethnically diverse populations. METHODS: This study included 105 families of children aged 2 to 15 years of Hispanic origin and low income undergoing outpatient tonsillectomy and adenoidectomy surgery. Participating parents completed baseline and demographic packets. Recorded postoperative pain ratings and administration of analgesics at home for 1 week were collected during home visits. RESULTS: Despite the high (70%; 99% confidence interval [CI], 57%–82%) incidence of significant pain in the first 24 hours home, 32% (95% CI, 20%–45%) of the children received 0 to 1 dose of analgesia. Overall, 21% children (99% CI, 11%–35%) received 4 or less total doses of pain medication over the entire week after surgery. Of the total analgesic doses administered to children in the week after surgery, only 44% (99% CI, 40%–47%) were in accepted ranges. CONCLUSIONS: Despite experiencing significant postoperative pain, Hispanic children assessed in this study received suboptimal analgesic therapy at home

    The TURis System for Transurethral Resection of the Prostate: A NICE Medical Technology Guidance

    Get PDF
    The transurethral resection in saline (TURis) system was notified by the company Olympus Medical to the National Institute of Health and Care Excellence’s (NICE’s) Medical Technologies Evaluation Programme. Following selection for medical technologies guidance, the company developed a submission of clinical and economic evidence for evaluation. TURis is a bipolar surgical system for treating men with lower urinary tract symptoms due to benign prostatic enlargement. The comparator is any monopolar transurethral resection of the prostate (mTURP) system. Cedar, a collaboration between Cardiff and Vale University Health Board, Cardiff University and Swansea University in the UK, acted as an External Assessment Centre (EAC) for NICE to independently critique the company’s submission of evidence. Eight randomised trials provided evidence for TURis, demonstrating efficacy equivalent to that of mTURP for improvement of symptoms. The company presented meta-analyses of key outcome measures, and the EAC made methodological modifications in response to the heterogeneity of the trial data. The EAC analysis found that TURis substantially reduced the relative risks of transurethral resection syndrome (relative risk 0.18 [95 % confidence interval 0.05–0.62]) and blood transfusion (relative risk 0.35 [95 % confidence interval 0.19–0.65]). The company provided a de novo economic model comparing TURis with mTURP. The EAC critiqued the model methodology and made modifications. This found TURis to be cost saving at £70.55 per case for existing Olympus customers and cost incurring at £19.80 per case for non-Olympus customers. When an additional scenario based on the only available data on readmission (due to any cause) from a single trial was modelled, the estimated cost saving per case was £375.02 for existing users of Olympus electrosurgery equipment and £284.66 per case when new Olympus equipment would need to be purchased. Meta-analysis of eight randomised trials showed that TURis is associated with a statistically significantly reduced risk of transurethral resection syndrome and a reduced need for blood transfusion—two factors that may drive cost saving for the National Health Service. The clinical data are equivocal as to whether TURis shortens the hospital stay. Limited data from a single study suggest that TURis may reduce the rate of readmission after surgery. The NICE guidance supports adoption of the TURis technology for performing transurethral resection of the prostate in men with lower urinary tract symptoms due to benign prostatic enlargemen

    Electronic and paper versions of a faces pain intensity scale: concordance and preference in hospitalized children

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Assessment of pain in children is an important aspect of pain management and can be performed by observational methods or by self-assessment. The Faces Pain Scale-Revised (FPS-R) is a self-report tool which has strong positive correlations with other well established self-report pain intensity measures. It has been recommended for measuring pain intensity in school-aged children (4 years and older). The objective of this study is to compare the concordance and the preference for two versions, electronic and paper, of the FPS-R, and to determine whether an electronic version of the FPS-R can be used by children aged 4 and older.</p> <p>Methods</p> <p>The study is an observational, multicenter, randomized, cross-over, controlled, open trial. Medical and surgical patients in two pediatric hospitals (N = 202, age 4-12 years, mean age 8.3 years, 58% male) provided self-reports of their present pain using the FPS-R on a personal digital assistant (PDA) and on a paper version. Paper and electronic versions of the FPS-R were administered by a nurse in a randomized order: half the patients were given the PDA version first and the other half the paper version first. The time between the administrations was planned to be less than 30 minutes but not simultaneous. Two hundred and thirty-seven patients were enrolled; 35 were excluded from analysis because of misunderstanding of instructions or abnormal time between the two assessments.</p> <p>Results</p> <p>Final population for analysis comprised 202 children. The overall weighted Kappa was 0.846 (95%CI: 0.795; 0.896) and the Spearman correlation between scores on the two versions was r<sub>s </sub>= 0.911 (p < 0.0001). The mean difference of pain scores was less than 0.1 out of 10, which was neither statistically nor clinically significant; 83.2% of children chose the same face on both versions of the FPS-R. Preference was not modified by order, sex, age, hospitalization unit (medical or surgical units), or previous analgesics. The PDA was preferred by 87.4% of the children who expressed a preference.</p> <p>Conclusion</p> <p>The electronic version of the FPS-R can be recommended for use with children aged 4 to 12, either in clinical trials or in hospitals to monitor pain intensity.</p

    Results of a randomized, double blind, placebo controlled, crossover trial of melatonin for treatment of Nocturia in adults with multiple sclerosis (MeNiMS)

    Get PDF
    © 2018 The Author(s). Background: Nocturia is a common urinary symptom of multiple sclerosis (MS) which can affect quality of life (QoL) adversely. Melatonin is a hormone known to regulate circadian rhythm and reduce smooth muscle activity such as in the bladder. There is limited evidence supporting use of melatonin to alleviate urinary frequency at night in the treatment of nocturia. The aim of this study was to evaluate the effect of melatonin on the mean number of nocturia episodes per night in patients with MS. Methods: A randomized, double blind, placebo controlled crossover trial was conducted. 34 patients with nocturia secondary to multiple sclerosis underwent a 4-day pre-treatment monitoring phase. The patients were randomized to receive either 2 mg per night (taken at bedtime) of capsulated sustained-release melatonin (Circadin®) or 1 placebo capsule for 6 weeks followed by a crossover to the other regimen for an additional 6 weeks after a 1-month washout period. Results: From the 26 patients who completed the study, there was no significant difference observed in the signs or symptoms of nocturia when taking 2 mg melatonin compared to placebo. The primary outcome measure, mean number of nocturia episodes on bladder diaries, was 1.8/night at baseline, and 1.4/night on melatonin, compared with 1.6 for placebo (Medians 1.70, 1.50, and 1.30 respectively, p = 0.85). There was also no significant difference seen in LUTS, QoL and sleep quality when taking melatonin. No significant safety concerns arose. Conclusions: This small study suggests that a low dose of melatonin taken at bedtime may be ineffective therapy for nocturia in MS. Trial registration: (EudraCT reference) 2012-00418321 registered: 25/01/13. ISRCTN Registry: ISRCTN38687869

    Protocol for a randomized, double blind, placebo controlled, crossover trial of Melatonin for treatment of Nocturia in adults with Multiple Sclerosis (MeNiMS)

    Get PDF
    © 2017 The Author(s). Background: Nocturia (the symptom of needing to wake up to pass urine) is common in progressive Multiple Sclerosis (MS) patients. Moderate-to-severe nocturia affects quality of life, can exacerbate fatigue and may affect capacity to carry out daily activities. Melatonin is a natural hormone regulating circadian cycles, released by the pineal gland at night-time, and secretion is impaired in MS. Melatonin levels can be supplemented by administration in tablet form at bedtime. The aim of this study is to evaluate the effect of melatonin on mean number of nocturia episodes per night in MS patients. Secondary outcome measures will assess impact upon quality of life, urinated volumes, lower urinary tract symptoms (LUTS), cognition, sleep quality and sleep disturbance of partners. Methods: A randomized, double blind, placebo controlled, crossover trial consisting of two, six week treatment phases (active drug melatonin 2 mg or placebo), with a 1 month wash-out period in between. The primary outcome (change in nocturia episodes per night) in this two arm, two treatment, two period crossover design, will be objectively measured using frequency volume charts (FVC) at baseline and following both treatment phases. Questionnaires will be used to assess quality of life, sleep quality, safety and urinary tract symptoms. Qualitative interviews of participants and partners will explore issues including quality of life, mechanisms of sleep disturbance and impact of nocturia on partners. Discussion: This study will evaluate whether melatonin reduces the frequency of nocturia episodes in MS patients, and therefore whether 'Circadin' has the potential to reduce LUTS and fatigue, and improve cognition and overall quality of life. Trial registration: (EudraCT reference) 2012-00418321 registered: 25/01/13. ISRCTN Registry: ISRCTN3868786

    A Wide-Angle Pattern Diversity Antenna System for mmWave 5G Mobile Terminals

    No full text
    A shared ground shared radiator with wide angular coverage for mmWave 5G smartphones is proposed in this paper. A four-element corporate-fed array with conventional impedance matched power divider is designed. Stepped impedance transformers are integrated with the corner most elements to achieve pattern diversity with wide angular coverage without significant compromise in gain. The proposed three-port shared radiator conformal commercial antenna could be easily integrated with commercial mmWave 5G smartphones. All the three ports&rsquo; excitations operate in the 28 GHz band. Radiation pattern bandwidth of the multi-port system is high. The gain variation is from 6 to 11 dBi amongst the ports and across the operating spectrum. The highest mutual coupling is 10 dB, in spite of the electrically connected structure. The proposed shared radiator element has a wide angular coverage of 100&deg;, maintaining high front-to-back ratio when the respective port is excited. Simulation and measurement results for the proposed structure are illustrated in detail
    • …
    corecore