41 research outputs found

    Early sexual dimorphism in the developing gut microbiome of northern elephant seals

    Get PDF
    The gut microbiome is an integral part of a species’ ecology, but we know little about how host characteristics impact its development in wild populations. Here, we explored the role of such intrinsic factors in shaping the gut microbiome of northern elephant seals during a critical developmental window of six weeks after weaning, when the pups stay ashore without feeding. We found substantial sex-differences in the early-life gut microbiome, even though males and females could not yet be distinguished morphologically. Sex and age both explained around 15% of the variation in gut microbial beta diversity, while microbial communities sampled from the same individual showed high levels of similarity across time, explaining another 40% of the variation. Only a small proportion of the variation in beta diversity was explained by health status, assessed by full blood counts, but clinically healthy individuals had a greater microbial alpha diversity than their clinically abnormal peers. Across the post-weaning period, the northern elephant seal gut microbiome was highly dynamic. We found evidence for several colonisation and extinction events as well as a decline in Bacteroides and an increase in Prevotella, a pattern that has previously been associated with the transition from nursing to solid food. Lastly, we show that genetic relatedness was correlated with gut microbiome similarity in males but not females, again reflecting early sex-differences. Our study represents a naturally diet-controlled and longitudinal investigation of how intrinsic factors shape the early gut microbiome in a species with extreme sex differences in morphology and life history

    The association of intra-therapeutic heterogeneity of somatostatin receptor expression with morphological treatment response in patients undergoing PRRT with [177Lu]-DOTATATE

    Get PDF
    AIM: Purpose of this study was to evaluate the association of the spatial heterogeneity (asphericity, ASP) in intra-therapeutic SPECT/ CT imaging of somatostatin receptor (SSR) positive metastatic gastroenteropancreatic neuroendocrine neoplasms (GEP-NEN) for morphological treatment response to peptide receptor radionuclide therapy (PRRT). Secondly, we correlated ASP derived form a pre-therapeutic OctreoScan (ASP[In]) and an intra-therapeutic [177Lu]-SPECT/CT (ASP[Lu]). MATERIALS AND METHODS: Data from first therapy cycle [177Lu-DOTA0-Tyr3]octreotate ([177Lu]-DOTATATE)-PRRT was retrospectively analyzed in 33 patients (m = 20; w = 13; median age, 72 [46-88] years). The evaluation of response to PRRT was performed according to RECIST 1.1 in responding lesions [RL (SD, PR, CR), n = 104] and non-responding lesions [NRL (PD), n = 27]. The association of SSR tumor heterogeneity with morphological response was evaluated by Kruskal-Wallis test and receiver operating characteristic curve (ROC). The optimal threshold for separation (RL vs. NRL) was calculated using the Youden-index. Relationship between pre- and intra-therapeutic ASP was determined with Spearman's rank correlation coefficient (ρ) and Bland-Altman plots. RESULTS: A total of 131 lesions (liver: n = 59, lymph nodes: n = 48, bone: n = 19, pancreas: n = 5) were analyzed. Lesions with higher ASP values showed a significantly poorer response to PRRT (PD, median: 11.3, IQR: 8.5-15.5; SD, median: 3.4, IQR: 2.1-4.5; PR, median 1.7, IQR: 0.9-2.8; CR, median: 0.5, IQR: 0.0-1.3); Kruskal-Wallis, p5.45% (sensitivity 96% and specificity 82%). The correlation coefficient of pre- and intra-therapeutic ASP revealed ρ = 0.72 (p <0.01). The mean absolute difference between ASP[In] and ASP[Lu] was -0.04 (95% Limits of Agreement, -6.1-6.0). CONCLUSION: Pre- and intra-therapeutic ASP shows a strong correlation and might be an useful tool for therapy monitoring

    Hybrid SPECT/CT for the assessment of a painful hip after uncemented total hip arthroplasty

    Get PDF
    Background The diagnosis of hip pain after total hip replacement (THR) represents a highly challenging question that is of increasing concern to orthopedic surgeons. This retrospective study assesses bone scintigraphy with Hybrid SPECT/CT for the diagnosis of painful THR in a selected cohort of patients. Methods Bone SPECT/CT datasets of 23 patients (mean age 68.9 years) with a painful hip after THR were evaluated. Selection of the patients required an inconclusive radiograph, normal serum levels of inflammatory parameters (CRP and ESR) or a negative aspiration of the hip joint prior to the examination. The standard of reference was established by an interdisciplinary adjudication-panel using all imaging data and clinical follow-up data (>12 month). Pathological and physiological uptake patterns were defined and applied. Results The cause of pain in this study group could be determined in 18 out of 23 cases. Reasons were aseptic loosening (n = 5), spine-related (n = 5), heterotopic ossification (n = 5), neuronal (n = 1), septic loosening (n = 1) and periprosthetic stress fracture (n = 1). In (n = 5) cases the cause of hip pain could not be identified. SPECT/CT imaging correctly identified the cause of pain in (n = 13) cases, in which the integrated CT-information led to the correct diagnosis in (n = 4) cases, mainly through superior anatomic correlation. Loosening was correctly assessed in all cases with a definite diagnosis. Conclusions SPECT/CT of THA reliably detects or rules out loosening and provides valuable information about heterotopic ossifications. Furthermore differential diagnoses may be detected with a whole-body scan and mechanical or osseous failure is covered by CT- imaging. SPECT/CT holds great potential for imaging-based assessment of painful prostheses

    Comparison of the structure and flexural properties of Moso, Guadua and Tre Gai bamboo

    Get PDF
    Bamboo is an underutilized resource widely available in countries with rapidly developing economies. Structural bamboo products, analogous to wood products, allow flexibility in the shape and dimensions of bamboo structural members. Here, the ultrastructure, microstructure, cell wall properties and flexural properties of three species of bamboo (Moso, Guadua and Tre Gai) are compared. At a given density, the axial modulus of elasticity of Guadua is higher than that of Moso or Tre Gai, which are similar; ultrastructural results suggest that Guadua has a higher solid cell wall stiffness. At a given density, their moduli of rupture are similar.National Science Foundation (U.S.) (OISE-1258574

    Effect of remote ischaemic conditioning on clinical outcomes in patients with acute myocardial infarction (CONDI-2/ERIC-PPCI): a single-blind randomised controlled trial.

    Get PDF
    BACKGROUND: Remote ischaemic conditioning with transient ischaemia and reperfusion applied to the arm has been shown to reduce myocardial infarct size in patients with ST-elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI). We investigated whether remote ischaemic conditioning could reduce the incidence of cardiac death and hospitalisation for heart failure at 12 months. METHODS: We did an international investigator-initiated, prospective, single-blind, randomised controlled trial (CONDI-2/ERIC-PPCI) at 33 centres across the UK, Denmark, Spain, and Serbia. Patients (age >18 years) with suspected STEMI and who were eligible for PPCI were randomly allocated (1:1, stratified by centre with a permuted block method) to receive standard treatment (including a sham simulated remote ischaemic conditioning intervention at UK sites only) or remote ischaemic conditioning treatment (intermittent ischaemia and reperfusion applied to the arm through four cycles of 5-min inflation and 5-min deflation of an automated cuff device) before PPCI. Investigators responsible for data collection and outcome assessment were masked to treatment allocation. The primary combined endpoint was cardiac death or hospitalisation for heart failure at 12 months in the intention-to-treat population. This trial is registered with ClinicalTrials.gov (NCT02342522) and is completed. FINDINGS: Between Nov 6, 2013, and March 31, 2018, 5401 patients were randomly allocated to either the control group (n=2701) or the remote ischaemic conditioning group (n=2700). After exclusion of patients upon hospital arrival or loss to follow-up, 2569 patients in the control group and 2546 in the intervention group were included in the intention-to-treat analysis. At 12 months post-PPCI, the Kaplan-Meier-estimated frequencies of cardiac death or hospitalisation for heart failure (the primary endpoint) were 220 (8·6%) patients in the control group and 239 (9·4%) in the remote ischaemic conditioning group (hazard ratio 1·10 [95% CI 0·91-1·32], p=0·32 for intervention versus control). No important unexpected adverse events or side effects of remote ischaemic conditioning were observed. INTERPRETATION: Remote ischaemic conditioning does not improve clinical outcomes (cardiac death or hospitalisation for heart failure) at 12 months in patients with STEMI undergoing PPCI. FUNDING: British Heart Foundation, University College London Hospitals/University College London Biomedical Research Centre, Danish Innovation Foundation, Novo Nordisk Foundation, TrygFonden

    Brain atlas of the Mongolian gerbil (Meriones unguiculatus) in CT/MRI-aided stereotaxic coordinates

    No full text
    A new stereotaxic brain atlas of the Mongolian gerbil (Meriones unguiculatus), an important animal model in neurosciences, is presented. It combines high-quality histological material for identification of brain structures with reliable stereotaxic coordinates. The atlas consists of high-resolution images of frontal sections alternately stained for cell bodies (Nissl) and myelinated fibers (Gallyas) of 62 rostro-caudal levels at intervals of 350 μm. Brain structures were named according to the Paxinos nomenclature for rodents. The accuracy of the stereotaxic coordinate system was improved substantially by comparing and matching the series of histological sections to in vivo brain images of the gerbil obtained by magnetic resonance imaging (MRI). The skull outlines corresponding to the MR images were acquired using X-ray computerized tomography (CT) and were used to establish the relationship between coordinates of brain structures and skull. Landmarks such as lambda, bregma, ear canals and occipital crest can be used to line up skull and brain in standard atlas coordinates. An easily reproducible protocol allows sectioning of experimental brains in the standard frontal plane of the atlas

    Improvement of image quality and dose management in CT fluoroscopy by iterative 3D image reconstruction

    No full text
    The objective of this study was to assess the influence of an iterative CT reconstruction algorithm (IA), newly available for CT-fluoroscopy (CTF), on image noise, readers' confidence and effective dose compared to filtered back projection (FBP). Data from 165 patients (FBP/IA = 82/74) with CTF in the thorax, abdomen and pelvis were included. Noise was analysed in a large-diameter vessel. The impact of reconstruction and variables (e.g. X-ray tube current I) influencing noise and effective dose were analysed by ANOVA and a pairwise t-test with Bonferroni-Holm correction. Noise and readers' confidence were evaluated by three readers. Noise was significantly influenced by reconstruction, I, body region and circumference (all p ae currency 0.0002). IA reduced the noise significantly compared to FBP (p = 0.02). The effect varied for body regions and circumferences (p aecurrency 0.001). The effective dose was influenced by the reconstruction, body region, interventional procedure and I (all p ae currency 0.02). The inter-rater reliability for noise and readers' confidence was good (W ae yen 0.75, p 0.03). Generally, IA yielded a significant reduction of the median effective dose. The CTF reconstruction by IA showed a significant reduction in noise and effective dose while readers' confidence increased. aEuro cent CTF is performed for image guidance in interventional radiology. aEuro cent Patient exposure was estimated from DLP documented by the CT. aEuro cent Iterative CT reconstruction is appropriate to reduce image noise in CTF. aEuro cent Using iterative CT reconstruction, the effective dose was significantly reduced in abdominal interventions

    Analysis of Bone Scans in Various Tumor Entities Using a Deep-Learning-Based Artificial Neural Network Algorithm—Evaluation of Diagnostic Performance

    No full text
    The bone scan index (BSI), initially introduced for metastatic prostate cancer, quantifies the osseous tumor load from planar bone scans. Following the basic idea of radiomics, this method incorporates specific deep-learning techniques (artificial neural network) in its development to provide automatic calculation, feature extraction, and diagnostic support. As its performance in tumor entities, not including prostate cancer, remains unclear, our aim was to obtain more data about this aspect. The results of BSI evaluation of bone scans from 951 consecutive patients with different tumors were retrospectively compared to clinical reports (bone metastases, yes/no). Statistical analysis included entity-specific receiver operating characteristics to determine optimized BSI cut-off values. In addition to prostate cancer (cut-off = 0.27%, sensitivity (SN) = 87%, specificity (SP) = 99%), the algorithm used provided comparable results for breast cancer (cut-off 0.18%, SN = 83%, SP = 87%) and colorectal cancer (cut-off = 0.10%, SN = 100%, SP = 90%). Worse performance was observed for lung cancer (cut-off = 0.06%, SN = 63%, SP = 70%) and renal cell carcinoma (cut-off = 0.30%, SN = 75%, SP = 84%). The algorithm did not perform satisfactorily in melanoma (SN = 60%). For most entities, a high negative predictive value (NPV &ge; 87.5%, melanoma 80%) was determined, whereas positive predictive value (PPV) was clinically not applicable. Automatically determined BSI showed good sensitivity and specificity in prostate cancer and various other entities. Particularly, the high NPV encourages applying BSI as a tool for computer-aided diagnostic in various tumor entities
    corecore