242 research outputs found

    Estimation of In Vivo Water Content of the Stratum Corneum from Electrical Measurements

    Get PDF
    In vivo water content in the epidermal stratum corneum can be estimated by means of low frequency susceptance measurements. In the in vitro calibration necessary to find the in vivo water content, the stratum corneum will have a uniform distribution of water across its thickness. However, in vivo stratum corneum has an increasing water concentration profile from the outermost towards the innermost parts. This paper will investigate the possibility of estimating the equilibrium water content in the in vivo stratum corneum non-invasively from electrical susceptance measurements. Given a known shape of the water concentration profile in the in vivo stratum corneum and the dependence of susceptance on the water content, it is possible to calculate the water content in vivo based on analytically derived expressions for the water concentration profile. A correspondence between in vivo and in vitro water content needed for this purpose is also established

    Microfluidic Impedance Spectroscopy as a Tool for Quantitative Biology and Biotechnology

    Get PDF
    A microfluidic device that is able to perform dielectric spectroscopy is developed. The device consists of a measurement chamber that is 250 μm thick and 750 μm radius. Around 1000 cells fit inside the chamber assuming average quantities for cell radius and volume fraction. This number is about 1000 folds lower than the capacity of conventional fixtures. A T-cell leukemia cell line Jurkat is tested using the microfluidic device. Measurements of deionized water and salt solutions are utilized to determine parasitic effects and geometric capacitance of the device. Physical models, including Maxwell-Wagner mixture and double shell models, are used to derive quantities for sub-cellular units. Clausius-Mossotti factor of Jurkat cells is extracted from the impedance spectrum. Effects of cellular heterogeneity are discussed and parameterized. Jurkat cells are also tested with a time domain reflectometry system for verification of the microfluidic device. Results indicate good agreement of values obtained with both techniques. The device can be used as a unique cell diagnostic tool to yield information on sub-cellular units. (C) 2012 American Institute of Physics

    Low Serum Levels of 25-Hydroxyvitamin D Predict Hip Fracture in the Elderly: A NOREPOS Study

    Get PDF
    Background: Despite considerable interest, the relationship between circulating 25-hydroxyvitamin D and the risk of hip fracture is not fully established. Objective: The objective of the study was to study the association between serum 25-hydroxyvitamin D concentrations [s-25(OH)D] and the risk of hip fracture in Norway, a high-latitude country that has some of the highest hip fracture rates worldwide. Methods: A total of 21 774 men and women aged 65–79 years attended 4 community-based health studies during 1994–2001. Information on subsequent hip fractures was retrieved from electronic hospital discharge registers, with a maximum follow-up of 10.7 years. Using a stratified case-cohort design, s-25(OH)D was determined by HPLC-atmospheric pressure chemical ionization-mass spectrometry in stored serum samples in hip fracture cases (n = 1175; 307 men, 868 women) and in gender-stratified random samples (n = 1438). Cox proportional hazards regression adapted for the case-cohort design was performed. Results: We observed an inverse association between s-25(OH)D and hip fracture; those with s-25(OH)D in the lowest quartile (<42.2 nmol/L) had a 38% [95% confidence interval (CI) 9–74%] increased risk of hip fracture compared with the highest quartile (≥67.9 nmol/L) in a model accounting for age, gender, study center, and body mass index. The association was stronger in men than in women: hazard ratio 1.65 (95% CI 1.04–2.61) vs hazard ratio 1.25 (95% CI 0.95–1.65). Conclusion: In this prospective case-cohort study of hip fractures, the largest ever reported, we found an increased risk of hip fracture in subjects in the lowest compared with the highest quartile of serum 25-hydroxyvitamin D. In accordance with the findings of previous community-based studies, low vitamin D status was a modest risk factor for hip fracture.publishedVersio

    Electrical impedance tomography system: an open access circuit design

    Get PDF
    BACKGROUND: This paper reports a simple 2-D system for electrical impedance tomography EIT, which works efficiently and is low cost. The system has been developed in the Sharif University of Technology Tehran-Iran (for the author's MSc Project). METHODS: The EIT system consists of a PC in which an I/O card is installed with an external current generator, a multiplexer, a power supply and a phantom with an array of electrodes. The measurement system provides 12-bit accuracy and hence, suitable data acquisition software has been prepared accordingly. The synchronous phase detection method has been implemented for voltage measurement. Different methods of image reconstruction have been used with this instrument to generate electrical conductivity images. RESULTS: The results of simulation and real measurement of the system are presented. The reconstruction programs were written in MATLAB and the data acquisition software in C++. The system has been tested with both static and dynamic mode in a 2-D domain. Better results have been produced in the dynamic mode of operation, due to the cancellation of errors. CONCLUSION: In the spirit of open access publication the design details of this simple EIT system are made available here

    Staphylococcus aureus nasal carriage is associated with serum 25-hydroxyvitamin D levels, gender and smoking status. The Tromsø Staph and Skin Study

    Get PDF
    Vitamin D induces the expression of antimicrobial peptides with activity against Staphylococcus aureus. Thus, we studied the association between serum 25-hydroxyvitamin D (25(OH)D) and S. aureus nasal colonization and carriage. Nasal swabs, blood samples and clinical data from 2,115 women and 1,674 men, aged 30–87 years, were collected in the Tromsø Staph and Skin Study 2007–08, as part of the population-based sixth Tromsø Study. Multivariate logistic regression analyses were stratified by recognized risk factors for S. aureus carriage: sex, age and smoking. In non-smoking men, we observed a 6.6% and 6.7% decrease in the probability of S. aureus colonization and carriage, respectively, by each 5 nmol/l increase in serum 25(OH)D concentration (P < 0.001 and P = 0.001), and serum 25(OH)D > 59 nmol/l and ≥75 nmol/l as thresholds for ~30% and ~50% reduction in S. aureus colonization and carriage. In non-smoking men aged 44–60 years, the odds ratio for S. aureus colonization was 0.44 (95% confidence interval, 0.28−0.69) in the top tertile of serum 25(OH)D versus the bottom tertile. In women and smokers there were no such associations. Our study supports that serum vitamin D is a determinant of S. aureus colonization and carriage

    Real-time estimation of horizontal gaze angle by saccade integration using in-ear electrooculography

    Get PDF
    The manuscript proposes and evaluates a real-time algorithm for estimating eye gaze angle based solely on single-channel electrooculography (EOG), which can be obtained directly from the ear canal using conductive ear moulds. In contrast to conventional high-pass filtering, we used an algorithm that calculates absolute eye gaze angle via statistical analysis of detected saccades. The estimated eye positions of the new algorithm were still noisy. However, the performance in terms of Pearson product-moment correlation coefficients was significantly better than the conventional approach in some instances. The results suggest that in-ear EOG signals captured with conductive ear moulds could serve as a basis for lightweight and portable horizontal eye gaze angle estimation suitable for a broad range of applications. For instance, for hearing aids to steer the directivity of microphones in the direction of the user’s eye gaze

    No significant effect on bone mineral density by high doses of vitamin D3 given to overweight subjects for one year

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In meta-analyses supplementation with vitamin D appears to reduce incidence of fractures, and in cross-sectional studies there is a positive association between serum 25-hydroxyvitamin D (25(OH)D) levels and bone mineral density (BMD). However, the effect of supplementation with high doses of vitamin D on BMD is more uncertain and could in theory have both positive and negative effects.</p> <p>Methods</p> <p>The study was a one year, double blind placebo-controlled intervention trial performed at the University Hospital of North Norway. 421 subjects, 21 - 70 years old, were included and 312 completed the study. The subjects were randomized to vitamin D<sub>3 </sub>40.000 IU per week (DD group), vitamin D<sub>3 </sub>20.000 IU per week (DP group), or placebo (PP group). All subjects were given 500 mg calcium daily. Serum 25(OH)D, osteoprotegrin (OPG), receptoractivator of nuclear factor-kappaB ligand (RANKL), and BMD at the lumbar spine and the hip were measured before and at the end of the study.</p> <p>Results</p> <p>At baseline the mean serum 25(OH)D levels were 58 nmol/L (all subjects) and increased to 141 and 100 nmol/L in the DD and DP groups, respectively. After one year, no significant differences were found between the three groups regarding change in BMD, serum OPG or RANKL.</p> <p>Conclusions</p> <p>Supplementation with high doses of vitamin D for one year does not appear to have a negative effect on BMD in healthy subjects. In order to disclose a positive effect, subjects with low BMD and/or low serum 25(OH)D levels need to be studied.</p> <p>Trial registration</p> <p>The trial was registered at ClinicalTrials.gov (NCT00243256).</p

    Chronic Obstructive Pulmonary Disease Is Associated with Low Levels of Vitamin D

    Get PDF
    Introduction: COPD patients may be at increased risk for vitamin D (25(OH)D) deficiency, but risk factors for deficiency among COPD patients have not been extensively reported. Methods: Serum 25(OH)D levels were measured by liquid chromatography double mass spectrometry in subjects aged 40–76 years from Western Norway, including 433 COPD patients (GOLD stage II-IV) and 325 controls. Levels <20 ng/mL defined deficiency. Season, sex, age, body mass index (BMI), smoking, GOLD stage, exacerbation frequency, arterial oxygen tension (PaO2), respiratory symptoms, depression (CES-D score≥16), comorbidities (Charlson score), treatment for osteoporosis, use of inhaled steroids, and total white blood count were examined for associations with 25(OH)D in both linear and logistic regression models. Results: COPD patients had an increased risk for vitamin D deficiency compared to controls after adjustment for seasonality, age, smoking and BMI. Variables associated with lower 25(OH)D levels in COPD patients were obesity ( = −6.63), current smoking ( = −4.02), GOLD stage III- IV ( = −4.71, = −5.64), and depression ( = −3.29). Summertime decreased the risk of vitamin D deficiency (OR = 0.22). Conclusion: COPD was associated with an increased risk of vitamin D deficiency, and important disease characteristics were significantly related to 25(OH)D levels
    corecore