76 research outputs found

    The water relations of two tropical rainforest species (Virola surinamensis and Eperua falcata): Is Virola unusual as previously reported?

    Get PDF
    HYDROInternational audienceThe objective of this study was to examine the water relations and hydraulic architecture and vulnerability to cavitation in Virola surinamensis and V. michelii and to compare to similar measurements in Eperua falcata. In several previous reports Virola was seen to have a rather narrow range of xylem pressure potentials (Ψx) near zero in the course of a wet-season day while having water fluxes quite close to Eperua. We tested the hypothesis that the narrow range of Ψx might be consistent with very high hydraulic conductivities of stems, roots and shoots and high vulnerability to cavitation in Virola compared to Eperua. When this hypothesis proved false we concluded that the previous determinations of Ψx might be wrong in Virola due to latex. We re-examined the determination of Ψx in Virola by the pressure chamber technique and compared results to determination of Ψleaf by the thermocouple psychrometer technique and found that the likely range of Ψx are more negative than previously reported. Problems concerning the determination of Ψx in species with latex are discussed

    Establishing Streptomycin Epidemiological Cut-Off Values for Salmonella and Escherichia coli

    Get PDF
    This study was conducted to elucidate the accuracy of the current streptomycin epidemiological cut-off value (ECOFF) for Escherichia coli and Salmonella spp. A total of 236 Salmonella enterica and 208 E. coli isolates exhibiting MICs between 4 and 32¿mg/L were selected from 12 countries. Isolates were investigated by polymerase chain reaction for aadA, strA, and strB streptomycin resistance genes. Out of 236 Salmonella isolates, 32 (13.5%) yielded amplicons for aadA (n¿=¿23), strA (n¿=¿9), and strB (n¿=¿11). None of the 60 Salmonella isolates exhibiting MIC 4¿mg/L harbored resistance genes. Of the Salmonella isolates exhibiting MICs 8¿mg/L, 16¿mg/L, and 32¿mg/L, 1.6%, 15%, and 39%, respectively, tested positive for one or more genes. For most monitoring programs, the streptomycin ECOFF for Salmonella is wild type (WT) =32 or =16¿mg/L. A cut-off value of WT =32¿mg/L would have misclassified 13.5% of the strains as belonging to the WT population, since this proportion of strains harbored resistance genes and exhibited MICs =32¿mg/L. Out of 208 E. coli strains, 80 (38.5%) tested positive for aadA (n¿=¿69), strA (n¿=¿18), and strB (n¿=¿31). Of the E. coli isolates exhibiting MICs of 4¿mg/L, 8¿mg/L, 16¿mg/L, and 32¿mg/L, 3.6%, 17.6%, 53%, and 82.3%, respectively, harbored any of the three genes. Based on the European Committee on Antimicrobial Susceptibility Testing guidelines (ECOFF =16¿mg/L), 25% of the E. coli strains presenting MIC =16¿mg/L would have been incorrectly categorized as belonging to the WT population. The authors recommend an ECOFF value of WT =16¿mg/L for Salmonella and WT =8¿mg/L for E. coli

    COVID-19 symptoms at hospital admission vary with age and sex: results from the ISARIC prospective multinational observational study

    Get PDF
    Background: The ISARIC prospective multinational observational study is the largest cohort of hospitalized patients with COVID-19. We present relationships of age, sex, and nationality to presenting symptoms. Methods: International, prospective observational study of 60 109 hospitalized symptomatic patients with laboratory-confirmed COVID-19 recruited from 43 countries between 30 January and 3 August 2020. Logistic regression was performed to evaluate relationships of age and sex to published COVID-19 case definitions and the most commonly reported symptoms. Results: ‘Typical’ symptoms of fever (69%), cough (68%) and shortness of breath (66%) were the most commonly reported. 92% of patients experienced at least one of these. Prevalence of typical symptoms was greatest in 30- to 60-year-olds (respectively 80, 79, 69%; at least one 95%). They were reported less frequently in children (≤ 18 years: 69, 48, 23; 85%), older adults (≥ 70 years: 61, 62, 65; 90%), and women (66, 66, 64; 90%; vs. men 71, 70, 67; 93%, each P < 0.001). The most common atypical presentations under 60 years of age were nausea and vomiting and abdominal pain, and over 60 years was confusion. Regression models showed significant differences in symptoms with sex, age and country. Interpretation: This international collaboration has allowed us to report reliable symptom data from the largest cohort of patients admitted to hospital with COVID-19. Adults over 60 and children admitted to hospital with COVID-19 are less likely to present with typical symptoms. Nausea and vomiting are common atypical presentations under 30 years. Confusion is a frequent atypical presentation of COVID-19 in adults over 60 years. Women are less likely to experience typical symptoms than men

    Pièges en spectroscopie de masse

    No full text
    International audienceP. 9. Préface / Alix GicquelP. 11. Introduction : le réseau Plasmas froids et la Mission des Ressources et Compétences Technologiques du CNRS / Gérard Lelièvre, Françoise Massines et Elodie Girard I - Génération et dissipation d'énergie P. 17. I-1. Absorbtion et dissipation d'énergie dans un plasma hors équilibre / J.-P. Bœuf P. 49. I-2. Plasmas hors-équilibre à des pressions atmosphériques / K. Hassouni, F. Massines, J.-M. Pouvesle P. 109. I-3. Les plasmas thermiques / A. Gleizes II - Accès aux caractéristiques et aux espèces du plasma P. 141. II-1. Le plasma d'arc dans le procédé de projection thermique / J.-F. Couderc P. 159. II-2. Mesures de sondes électrostatiques en plasma basse pression / S. Béchu P. 225. II-3. Diagnostics laser et spectroscopie de masse dans les plasmas réactifs / J. Jolly P. 255. II-4. Saturation optique et autres pièges en spectroscopie laser / N. Sadeghi P. 275. II-5. Pièges en spectroscopie de masse / A. Granier P. 297. II-6. Source d'ionisation par micro pointes pour la spectroscopie de masse spatiale / F. Cipriani, J.-M. Illiano, J.-J. Berthelier III - Technologie des réacteurs à plasmas P. 323. III-1. Plasmas micro-onde basses pressions excités à la résonance cyclotronique électronique / Y. Arnal P. 353. III-2. Technologie des réacteur à plasma: Dimensionnement des réacteurs à Plasma micro-onde haute pression / F. Sylva, G. Hagelaar, K. Hassouni, A. Gicquel P. 367. III-3. Technologie des réacteurs à plasmas: Plasmas inductifs et capacitifs en basse pression / Ph. Lefaucheux P. 391. III-4. Les Plasmas thermique / C. Verdy, R. Boblot, H. Deng, P. Gougeon, C. Codde

    Plasmas Froids: Cinétique, transports, transferts

    No full text
    pour le champs 'auteurs', les Directeurs de publications apparaissent en premier puis le Directeur de collection.International audienceI, Cinétiques électronique, chimique et ionique.|P. 15|I-1, Détermination de sections efficaces et paramètres de transport électroniques. / M.C.Bordage.|P. 47|I-2, Attachement électronique et recombinaison dissociative: études expérimentales et bases théoriques. / J.B.A. Mitchell, C. Rebrion-Rowe.|P. 69|I-3, Cinétique de réaction entre espèces neutres. / J.-L. Jauberteau, I. Jauberteau, J. Aubreton.|P. 85|I-4, Construction et réduction de schémas cinétiques complexes. / A. Dollet, S. de Persis, F. Teyssandier.|P. 127|I-5, Transport et instabilités dans les plasmas électronégatifs à basse pression. / P. Chabert.|II, Transports et Transferts.|P. 149|II-1, Hydrodynamique (principes de base et références). / E.Climent.|P. 165|II-2, Étude des couplages entre transport, chimie et transfert d'énergie dans les plasmas de décharge. / A. Bourdon, K. Hassouni, W. Morscheidt, G. Hagelaar, S. Longo, T.A. Grotjohn, G. Lombardi, X. Duten, F. Silva, A. Gicquel, F. Aréfi-Khonsari, M. Capitelli .|P. 243|II-3, Transfert d'énergie en plasmas thermiques. / P. Freton, J.-J. Gonzalez.|III, Nouvelles applications des Plasmas.|P. 261|III-1, Procédés plasma pour l'élaboration de piles à combustible à membrane électrolyte polymère. / S. Roualdès, J. Durand, P. Sistat, P. Brault, A. Gaillard, A.L. Thomann, J. Mathias, C. Charles, R. Boswell, T. Sauvage, R. Berjoan.|P. 283|III-2, Projection plasma de suspensions de particules submicroniques pour la réalisation de piles à combustible à électrolyte solide (SOFC). / V. Rat, C. Delbos, J.-F. Coudert, T. Chartier, P. Fauchais, L. Blanchi.|P. 299|III-3, Stérilisation du matériel médical. / S. Villeger, J.-P. Sarrette, A. Ricard.|P. 321|III-4, Plasma et catalyse pour la dépollution. / A. Khacef

    ETUDE COMPARATIVE DES PROCEDES DE DEPOT DE COUCHES MINCES PAR PLASMA D'ORGANOSILICIES (TEOS, HMDSO ET HMDSN)

    No full text
    NANTES-BU Sciences (441092104) / SudocSudocFranceF

    Plasmas Froids : Astrophysique, Aérospatial, Environnement, Biologie, Nanomatériaux

    No full text
    pour le champs 'auteurs', les Directeurs de publications apparaissent en premier puis le Directeur de collection.International audienceP. 9|Préface / Yvan Ségui.|P. 11|I, Plasmas et Astrophysique.|P. 13|I-1, Les Plasmas du Système Solaire et de l'Univers / Hervé de Feraudy.|P. 33|I-2, Instrumentation Plasma pour l'étude des Plasmas du Système Solaire / Jean-Jacques Berthelier.|P. 65|II, Plasmas et Aérospatial.|P. 67|II-1, La Propulsion électrique dans l'espace: Pourquoi, Comment ? Les développements en France / André Bouchoule.|P. 105|II-2, Propulsion Plasma - Nouveaux Concepts / Laurent Garrigues.|P. 123|II-3, Application des plasmas non thermiques au contrôle « électrofluidodynamique » des écoulements / Eric Moreau, Luc Léger, Alexandre Labergue, Guillermo Artana, Maxime Forte, Jérôme Pons, Christophe Louste, Gérard Touchard.|P. 179|III, Plasmas et Environnement.|P. 181|III-1, Association des plasmas non-thermiques à la catalyse: applications et verrous technologiques / Stéphane Pasquiers et Jean-Michel Tatibouët.|P. 215|III-2, Traitement de déchets en plasma d'arc: quelques exemples / Jean-Marie Baronnet.|P. 227|III-3, Sources de lumière du futur: Quels enjeux scientifiques, énergétiques, économiques et sociétaux ? / Georges Zissis et Jean-Baptiste Rouffet.|P. 247|IV, Plasmas et Biologie.|P. 249|IV-1, Les biofilms microbiens dans les bio-industries / R. Briandet, F. Dubois-Brissonnet, M. Naitali, T. Meylheuc, J.-M. Henry, A. Boubetra, M.N. Bellon-Fontaine.|P. 263|IV-2, Fonctionnalisation et structuration comme outils d'élaboration d'interfaces pour la fabrication de biocapteurs / F. Brétagnol, A. Valsesia, M. Lejeune, G. Ceccone, D. Gilliland, P. Colpo, F. Rossi.|P. 279|IV-3, Matériaux et dépôts ostéointégrables pour implants chirurgicaux, notamment orthopédiques : enjeux, défis et perspectives / Ghislain Montavon.|P. 323|V, Plasmas et Nanomatériaux.|P. 325|V-1, Potentialités des procédés PECVD et plasmas d'arc pour la synthèse de nanotubes et nanofibres de carbone / Tiberiu M. Minea, Manitra Razafinimanana, Jean-Jacques Gonzalez, Marc Monthioux.|P. 383|V-2, Agrégats et films nanostructurés par ablation laser / F. Dumas-Bouchiat, Corinne Champeaux, G. Trolliard, F. Rossignol, A. Catherinot.|P. 413|V-3, Nanoélectronique silicium Les plasmas froids : un excellent outil pour le nano / Pere Roca i Cabarrocas, Iran Thuat Nguyen

    Réhabilitation psychosociale (évaluation du soin de domiciliation directe)

    No full text
    L'habitat représente une place privilégiée d'inscription de l'identité. L'accès à un logement personnel constitue pour les patients psychiatriques chroniques un préalable à la réhabilitation psychosociale. Le Soin de Domiciliation Directe est un soin psychothérapique ayant pour objectif l'accès à un logement personnel, autonome et définitif, permettant d'éviter les appartements protégés. Nous proposons son évaluation après 7 ans et demi d'existence. 83 % des 94 patients domiciliés depuis plus de 2 ans, 81,8 % des 55 patients domiciliés depuis plus de 5 ans, vivent toujours en appartement autonome. Nous décrivons les facteurs en faveur d'un accès à un logement par ce soin, puis ceux en faveur d'une poursuite de la vie en logement autonome sur le long terme. Continuité de soin et accompagnement personnalisé du patient et de sa famille sont des facteurs de stabilité. Dépendances (aux soins, à la famille, aux substances) sont des facteurs d'échec. L'évolution clinique et sociodémographique des patients toujours domiciliés est positive ; leur qualité de vie et leur niveau d'autonomie sociale actuels sont supérieurs dans plusieurs domaines à ceux retrouvés dans la littérature.TOULOUSE3-BU Santé-Centrale (315552105) / SudocTOULOUSE3-BU Santé-Allées (315552109) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF

    Analyse expérimentale et modélisation du dépôt de films de Ti-Si-N par pulvérisation réactive r.f. magnétron

    No full text
    Cette thèse a pour thème l'étude expérimentale et la modélisation du dépôt de films minces de Ti-Si-N par pulvérisation réactive r.f. magnétron. Ces couches minces sont élaborées par pulvérisation d'une cible de Ti5Si3 dans un mélange réactif argon/azote. L'objectif de cette étude est de caractériser à la fois le plasma, la pulvérisation et les films minces afin de déterminer l'influence de la puissance rf et du pourcentage d'azote dans le mélange sur la structure et les propriétés des films de Ti-Si-N. Enfin, on étudie les propriétés de barrière à la diffusion du cuivre de ces films minces de Ti-Si-N pour des applications microélectronique.NANTES-BU Sciences (441092104) / SudocSudocFranceF

    Dépôt de couches minces par plasma pulsé radiofréquence et basse pression en mélange hexaméthyldisiloxane / oxygène

    No full text
    L'objectif de cette thèse est d'étudier le dépôt chimique en phase vapeur assisté par plasma (PECVD), à basse pression (3mTorr) et basse température (< 100C), en plasma pulsé (10Hz-1kHz) d'hexaméthyldisiloxane (HMDSO)/ oxygène dans un réacteur hélicon radiofréquence. La cinétique des espèces chargées et de certaines espèces neutres actives est déterminée à partir de mesures résolues en temps par sonde de Langmuir et spectroscopie d'émission optique. La caractérisation des dépôts par ellipsométrie, absorption infraouge et gravimétrie montre que des films inorganiques (SiO2) ou organiques (SiOxCyHz) peuvent être obtenus avec un même mélange de gaz suivant les paramètres de pulse. La structure et la vitesse de dépôt sont liées au temps de création et de perte des atomes d'oxygène. La réduction du bombardement ionique lors du dépôt en plasma pulsé permet de réduire les contraintes en compression et d'améliorer les propriétés électriques des films de SiO2.This work concerns the Plasma Enhanced Chemical Vapour Deposition (PECVD) of thin films, at low pressure (3mTorr) and low temperature (<100C), in Hexamethyldisiloxane (HMDSO)/ oxygen pulsed plasmas in a radiofrequency helicon reactor. The kinetics of charged species and of some neutral active species is investigated by Langmuir probe and optical emission spectroscopy time-resolved measurements. The film analysis by ellipsometry, infrared spectroscopy and gravimetry shows inorganic SiO2-like and plasma polymers SiOxCyHz films can be deposited with a fixed gas mixture depending on the pulse parameters. The structure and deposition rate are linked to the creation and loss times of oxygen atoms. The reduction of ion bombardment in pulsed plasma also allows to reduce the compressive stress and to improve the electrical properties of SiO2-like films, as demonstrated by nano-indentation, Newton's ring method, and C(V) and I(V) measurements on MOS structure.NANTES-BU Sciences (441092104) / SudocSudocFranceF
    corecore