122 research outputs found

    A fluorescence lifetime-based fibre-optic glucose sensor using glucose/galactose-binding protein

    Get PDF
    Alternative, non-electrochemistry-based technologies for continuous glucose monitoring are needed for eventual use in diabetes mellitus. As part of a programme investigating fluorescent glucose sensors, we have developed fibre-optic biosensors using glucose/galactose binding protein (GBP) labelled with the environmentally sensitive fluorophore, Badan. GBP-Badan was attached via an oligohistidine-tag to the surface of Ni-nitrilotriacetic acid (NTA)-functionalized agarose or polystyrene beads. Fluorescence lifetime increased in response to glucose, observed by fluorescence lifetime imaging microscopy of the GBP-Badan-beads. Either GBP-Badan agarose or polystyrene beads were loaded into a porous chamber at the end of a multimode optical fibre. Fluorescence lifetime responses were recorded using pulsed laser excitation, high speed photodiode detection and time-correlated single-photon counting. The maximal response was at 100 mM glucose with an apparent K-d of 13 mM (agarose) and 20 mM (polystyrene), and good working-day stability was demonstrated. We conclude that fluorescence lifetime fibre-optic glucose sensors based on GBP-Badan are suitable for development as clinical glucose monitors

    Flash Glucose-Sensing Technology as a Replacement for Blood Glucose Monitoring for the Management of Insulin-Treated Type 2 Diabetes: a Multicenter, Open-Label Randomized Controlled Trial

    Get PDF
    Introduction Glycemic control in participants with insulin-treated diabetes remains challenging. We assessed safety and efficacy of new flash glucose-sensing technology to replace self-monitoring of blood glucose (SMBG). Methods This open-label randomized controlled study (ClinicalTrials.gov, NCT02082184) enrolled adults with type 2 diabetes on intensive insulin therapy from 26 European diabetes centers. Following 2 weeks of blinded sensor wear, 2:1 (intervention/control) randomization (centrally, using biased-coin minimization dependant on study center and insulin administration) was to control (SMBG) or intervention (glucose-sensing technology). Participants and investigators were not masked to group allocation. Primary outcome was difference in HbA1c at 6 months in the full analysis set. Prespecified secondary outcomes included time in hypoglycemia, effect of age, and patient satisfaction. Results Participants (n = 224) were randomized (149 intervention, 75 controls). At 6 months, there was no difference in the change in HbA1c between intervention and controls: −3.1 ± 0.75 mmol/mol, [−0.29 ± 0.07% (mean ± SE)] and −3.4 ± 1.04 mmol/mol (−0.31 ± 0.09%) respectively; p = 0.8222. A difference was detected in participants aged <65 years [−5.7 ± 0.96 mmol/mol (−0.53 ± 0.09%) and −2.2 ± 1.31 mmol/mol (−0.20 ± 0.12%), respectively; p = 0.0301]. Time in hypoglycemia <3.9 mmol/L (70 mg/dL) reduced by 0.47 ± 0.13 h/day [mean ± SE (p = 0.0006)], and <3.1 mmol/L (55 mg/dL) reduced by 0.22 ± 0.07 h/day (p = 0.0014) for intervention participants compared with controls; reductions of 43% and 53%, respectively. SMBG frequency, similar at baseline, decreased in intervention participants from 3.8 ± 1.4 tests/day (mean ± SD) to 0.3 ± 0.7, remaining unchanged in controls. Treatment satisfaction was higher in intervention compared with controls (DTSQ 13.1 ± 0.50 (mean ± SE) and 9.0 ± 0.72, respectively; p < 0.0001). No serious adverse events or severe hypoglycemic events were reported related to sensor data use. Forty-two serious events [16 (10.7%) intervention participants, 12 (16.0%) controls] were not device-related. Six intervention participants reported nine adverse events for sensor-wear reactions (two severe, six moderate, one mild). Conclusion Flash glucose-sensing technology use in type 2 diabetes with intensive insulin therapy results in no difference in HbA1c change and reduced hypoglycemia, thus offering a safe, effective replacement for SMBG

    Sense and nonsense in sensors

    Get PDF
    Continuous subcutaneous glucose monitoring (CGM) is a developing technology in the treatment of diabetes mellitus. The first randomised controlled trials on its efficacy have been performed. In several studies, CGM lowered HbA1c in adult patients with suboptimally controlled type 1 diabetes mellitus, when selecting compliant patients who tolerate the device. However, as a preventive tool for hypoglycaemia, CGM has not fulfilled the great expectations. Increasing reimbursement of CGM is expected in the near future, awaiting studies on cost-effectiveness

    Recent Updates on Type 1 Diabetes Mellitus Management for Clinicians

    Get PDF
    Type 1 diabetes mellitus (T1DM) is a chronic autoimmune condition that requires life-long administration of insulin. Optimal management of T1DM entails a good knowledge and understanding of this condition both by the physician and the patient. Recent introduction of novel insulin preparations, technological advances in insulin delivery and glucose monitoring, such as continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring and improved understanding of the detrimental effects of hypoglycaemia and hyperglycaemia offer new opportunities and perspectives in T1DM management. Evidence from clinical trials suggests an important role of structured patient education. Our efforts should be aimed at improved metabolic control with concomitant reduction of hypoglycaemia. Despite recent advances, these goals are not easy to achieve and can put significant pressure on people with T1DM. The approach of physicians should therefore be maximally supportive. In this review, we provide an overview of the recent advances in T1DM management focusing on novel insulin preparations, ways of insulin administration and glucose monitoring and the role of metformin or sodium-glucose co-transporter 2 inhibitors in T1DM management. We then discuss our current understanding of the effects of hypoglycaemia on human body and strategies aimed at mitigating the risks associated with hypoglycaemia

    Evaluation of a minimally invasive glucose biosensor for continuous tissue monitoring

    Get PDF
    We describe here a minimally invasive glucose biosensor based on a microneedle array electrode fabricated from an epoxy-based negative photoresist (SU8 50) and designed for continuous measurement in the dermal compartment with minimal pain. These minimally invasive, continuous monitoring sensor devices (MICoMS) were produced by casting the structures in SU8 50, crosslinking and then metallising them with platinum or silver to obtain the working and reference electrodes, respectively. The metallised microneedle array electrodes were subsequently functionalised by entrapping glucose oxidase in electropolymerised polyphenol (PP) film. Sensor performance in vitro showed that glucose concentrations down to 0.5 mM could be measured with a response times (T90) of 15 s. The effect of sterilisation by Co60 irradiation was evaluated. In preparation for further clinical studies, these sensors were tested in vivo in a healthy volunteer for a period of 3–6 h. The sensor currents were compared against point measurements obtained with a commercial capillary blood glucometer. The epoxy MICoMS devices showed currents values that could be correlated with these
    • …