352 research outputs found

    Pramlintide but Not Liraglutide Suppresses Meal-Stimulated Glucagon Responses in Type 1 Diabetes

    Get PDF
    Postprandial hyperglycemia remains a challenge in type 1 diabetes (T1D) due, in part, to dysregulated increases in plasma glucagon levels after meals

    “It’s embarrassing. I get angry. I get frustrated.”: Understanding severe hypoglycemia and glucagon usage from the perspectives of people with type 1 diabetes

    Get PDF
    Introduction This study characterized the emotional impact of severe hypoglycemia, views of glucagon, and barriers to glucagon use from the perspective of adults with type 1 diabetes (T1D). Methods Participants included individuals recruited from the T1D Exchange online community. The current study conducted 7 focus groups consisting of adults with T1D (N = 38, average age 49.4, SD = 16.11 years). Average duration of diabetes was 34.4 years (SD = 17.3) and average self-reported A1c was 6.8 % (SD = 0.7). Focus group interviews were recorded, transcribed, and thematically analyzed. Results A range of emotions was expressed about severe hypoglycemia including fear, anxiety, stress, frustration, shame, and embarrassment. Participants frequently identified prescription cost and insurance deductibles as barriers to glucagon use. Participants were also concerned about ease of administration—how difficult it is to prepare the glucagon in an emergency. Many participants expressed a preference for auto-injectables over nasal administration. Timing of glucagon action and time to recovery were high priorities. Some participants, while they had not self-administered glucagon, were interested in a mini-dose glucagon they could self-administer. They also identified desirable characteristics of glucagon treatment including reduced cost, long shelf-life, and quick activation. Conclusions These results highlight the attitudes about severe hypoglycemia and emergency treatment with glucagon. Healthcare professionals should assess glucagon training needs and knowledge when they meet with their patients with diabetes

    Effects of insulin pump vs. injection treatment on quality of life and impact of disease scores in children with type 1 diabetes mellitus in a randomised, prospective comparison

    Get PDF
    Objective: Effects of pump treatment vs. four times daily injections were explored in children with diabetes with regard to quality of life and impact of disease as well as adverse effects and parameters of metabolic control. Methods: An open, parallel, randomized controlled prospective comparative study lasting 14months was completed by 38 type 1 children with diabetes (age 4-16yr) following a 3.5-months run-in phase. Standardized quality-of-life Pediatric Quality of life Inventory (PedsQL) and impact of disease scores were obtained every 3.5months as well as regular medical parameters. Parallel treatment group data and longitudinal within-patient data were analysed for each treatment modality. Results: Within-patient comparisons of the two treatment modalities showed significant improvement in PedsQL and impact scores after pump treatment. Treatment group comparisons did not show significant improvement. Pump treatment resulted in decreased symptomatic hypoglycaemia and lowered haemoglobin A1c by 0.22% after run in. Conclusions: Within-patient comparison suggests that metabolic control, frequency of severe hypoglycaemia (a threefold decrease), quality of life and impact of disease scores are improved by pump treatment in comparison to regular treatment with four daily insulin injections. © 2008 The Authors Journal compilation © 2008 Blackwell Munksgaard

    A Low Frequency Electromagnetic Sensor for Indirect Measurement of Glucose Concentration: In Vitro Experiments in Different Conductive Solutions

    Get PDF
    In recent years there has been considerable interest in the study of glucose-induced dielectric property variations of human tissues as a possible approach for non-invasive glycaemia monitoring. We have developed an electromagnetic sensor, and we tested in vitro its ability to estimate variations in glucose concentration of different solutions with similarities to blood (sodium chloride and Ringer-lactate solutions), differing though in the lack of any cellular components. The sensor was able to detect the effect of glucose variations over a wide range of concentrations (∼78–5,000 mg/dL), with a sensitivity of ∼0.22 mV/(mg/dL). Our proposed system may thus be useful in a new approach for non-invasive and non-contact glucose monitoring

    CGM-measured glucose values have a strong correlation with C-peptide, HbA1c and IDAAC, but do poorly in predicting C-peptide levels in the two years following onset of diabetes

    Get PDF
    AIMS/HYPOTHESIS: The aim of this work was to assess the association between continuous glucose monitoring (CGM) data, HbA1c, insulin-dose-adjusted HbA1c (IDAA1c) and C-peptide responses during the first 2 years following diagnosis of type 1 diabetes. METHODS: A secondary analysis was conducted of data collected from a randomised trial assessing the effect of intensive management initiated within 1 week of diagnosis of type 1 diabetes, in which mixed-meal tolerance tests were performed at baseline and at eight additional time points through 24 months. CGM data were collected at each visit. RESULTS: Among 67 study participants (mean age [± SD] 13.3 ± 5.7 years), HbA1c was inversely correlated with C-peptide at each time point (p < 0.001), as were changes in each measure between time points (p < 0.001). However, C-peptide at one visit did not predict the change in HbA1c at the next visit and vice versa. Higher C-peptide levels correlated with increased proportion of CGM glucose values between 3.9 and 7.8 mmol/l and lower CV (p = 0.001 and p = 0.02, respectively) but not with CGM glucose levels <3.9 mmol/l. Virtually all participants with IDAA1c < 9 retained substantial insulin secretion but when evaluated together with CGM, time in the range of 3.9-7.8 mmol/l and CV did not provide additional value in predicting C-peptide levels. CONCLUSIONS/INTERPRETATION: In the first 2 years after diagnosis of type 1 diabetes, higher C-peptide levels are associated with increased sensor glucose levels in the target range and with lower glucose variability but not hypoglycaemia. CGM metrics do not provide added value over the IDAA1c in predicting C-peptide levels

    Design and Evaluation of a Pervasive Coaching and Gamification Platform for Young Diabetes Patients

    Get PDF
    Self monitoring, personal goal-setting and coaching, education and social support are strategies to help patients with chronic conditions in their daily care. Various tools have been developed, e.g., mobile digital coaching systems connected with wearable sensors, serious games and patient web portals to personal health records, that aim to support patients with chronic conditions and their caregivers in realizing the ideal of self-management. We describe a platform that integrates these tools to support young patients in diabetes self-management through educational game playing, monitoring and motivational feedback. We describe the design of the platform referring to principles from healthcare, persuasive system design and serious game design. The virtual coach is a game guide that can also provide personalized feedback about the user’s daily care related activities which have value for making progress in the game world. User evaluations with patients under pediatric supervision revealed that the use of mobile technology in combination with web-based elements is feasible but some assumptions made about how users would connect to the platform were not satisfied in reality, resulting in less than optimal user experiences. We discuss challenges with suggestions for further development of integrated pervasive coaching and gamification platforms in medical practice
    corecore