16 research outputs found

    Resting-state EEG alpha/theta ratio related to neuropsychological testperformance in Parkinson’s Disease

    Get PDF
    Q2Q1Objective To determine possible associations of hemispheric-regional alpha/theta ratio (α/θ) with neuropsychological test performance in Parkinson’s Disease (PD) non-demented patients. Methods 36 PD were matched to 36 Healthy Controls (HC). The α/θ in eight hemispheric regions was computed from the relative power spectral density of the resting-state quantitative electroencephalogram (qEEG). Correlations between α/θ and performance in several neuropsychological tests were conducted, significant findings were included in a moderation analysis. Results The α/θ in all regions was lower in PD than in HC, with larger effect sizes in the posterior regions. Right parietal, and right and left occipital α/θ had significant positive correlations with performance in Judgement of Line Orientation Test (JLOT) in PD. Adjusted moderation analysis indicated that right, but not left, occipital α/θ influenced the JLOT performance related to PD. Conclusions Reduction of the occipital α/θ, in particular on the right side, was associated with visuospatial performance impairment in PD. Significance Visuospatial impairment in PD, which is highly correlated with the subsequent development of dementia, is reflected in α/θ in the right posterior regions. The right occipital α/θ may represent a useful qEEG marker for evaluating the presence of early signs of cognitive decline in PD and the subsequent risk of dementia.https://orcid.org/0000-0001-5832-0603Revista Internacional - Indexad

    El uso de energía en microempresas tradicionales. Eficiencia, innovación y gestión

    Get PDF
    Cualquiera que sepa que las microempresas en Medellín, actualmente suman cerca de 95.000 -algo así como el 96% del tejido empresarial-, y que generan alrededor del 50% del empleo de la ciudad, le interesará este libro. La razón es simple: en él se ofrecen modos muy concretos, no sólo de conservarlas sino de fortalecerlas. Haga el lector el siguiente ejercicio: cierre los ojos e imagine qué le ocurriría a la ciudad y a miles de sus familias si por algún albur, todas -o la mayoría- de las microempresas desaparecieran de repente. Seguramente lo que vería, no sería agradable, entonces abra los ojos y dispóngase a leer esta obra.El mensaje básico del presente libro es que usar eficientemente la energía, representa para todas las empresas, pero en particular para las micronegocios, beneficios no sólo en productividad y competitividad sino también en seguridad ocupacional y bienestar para sus dueños, sus familias y empleados, además de favorecer el medio ambiente. Alcanzar la eficiencia energética se logra tanto por disponer y adoptar buenas tecnologías energéticas, adecuadas instalaciones y espacios apropiados para su explotación, como gracias a las mejoras en los comportamientos y estilos de vida de los usuarios frente al consumo de las diversas fuentes de energía: hidroeléctrica, gas, carbón, leña, etc. En consecuencia, en esta obra se ofrecen a los microempresarios de estratos populares de la ciudad de Medellín, tanto alternativas tecnológicas y socioeconómicas que les permitan ser más eficientes y productivos, como un modelo de gestión energética que las haga viables y sostenibles en el tiempo.La conclusión del libro es clara: sin microempresas podrá haber crecimiento económico, pero nunca desarrollo humano incluyente y sostenible.  La novedad de la obra radica precisamente en que nunca antes las microempresas en el país habían sido conocidas y evaluadas desde el punto de vista de su eficiencia energética y menos aún, se habían hecho propuestas alcanzables para su mejoramiento y fortalecimiento.No sobra agregar que en su concepción y composición, en el libro participó un amplio grupo de académicos e investigadores de renombradas universidades de la ciudad, lo mismo que expertos y consultores tanto públicos como privados. Pero, sobre todo, este libro no hubiera sido posible sin la presencia constante y activa de los microempresarios que aportaron toda su buena voluntad para llevar a cabo el proyecto de investigación que le dio origen a la obra. A todos ellos se les hace un merecido reconocimiento a lo largo y ancho de sus páginas

    Análisis de un vertedero triangular de pared delgada con Ansys Fluent

    No full text

    Caracterización de la climatología y los efectos del ENSO sobre la isla de San Andrés, Colombia.

    Get PDF
    Usando datos de temperatura y velocidad de viento obtenidos a través de radiosonda en la isla San Andrés, y datos de lluvia de tres estaciones del IDEAM (Instituto de hidrología, Meteorología y Estudios Ambientales), se estudió el comportamiento del ciclo anual de estas tres variables y la influencia de los fenómenos macro-climáticos El Niño/Oscilación del Sur (ENSO por sus siglas en inglés), la Oscilación del Atlántico Norte (NAO) y las variaciones de temperatura en la superficie del Atlántico Tropical Norte (NTA-SST)

    Valoración de activos de renta variable para el mercado accionario colombiano en los sectores industrial, comercial y de servicios 2009-2013: Modelos Fama & French y Reward Beta

    No full text
    This research paper is based on the interest of presenting the results from the application of valuation of assets to equities for the Colombian stock market in the industrial, commercial and service sectors. For this purpose the valuation as multifactorial models Fama & French and Reward Beta develop. On the other hand, it arises in developing comparing two scenarios of time, the first short-term based on the zero coupon rate at 1 year and the other using long-term risk-free rate as the 10-year zero coupon. In research it is concluded that in estimating expected returns for equities in the Colombian stock market, the three-factor model is the one with better adjustment in the valuation results in the sample period.El presente artículo de investigación se fundamenta en el interés de presentar los resultados derivados en la aplicación de modelos de valoración de activos a los títulos de renta variable para el mercado accionario colombiano en los sectores industrial, comercial y servicios. Para tal propósito se desarrollan los modelos multifactoriales de valoración como Fama, French y Reward Beta. Por otro lado, se plantea en el desarrollo la comparación de dos escenarios de tiempo, el primero a corto plazo partiendo de la tasa cero cupón a 1 año y el otro a largo plazo usando como tasa libre de riesgo la cero cupón a 10 años. En la investigación se concluye que en la estimación de los retornos esperados para activos de renta variable en el mercado accionario colombiano, el modelo de tres factores es el que presenta mejor ajuste en los resultados de la valoración en el periodo de muestra

    Evaluation of load losses in the ventilation circuit by the use of fortification in coal mines, study case: nechí mine, amagá, antioquia

    Get PDF
    The research aims to identify the variables which influence on the increase of risk for explosions in underground coal mines, especially in the accumulation of coal dust on top of the fortification, as well as analyze how these affect the load losses in the ventilation circuit and the proper evacuation of coal dust. This analysis was carried out by a guide field visits to Nechí Mine (Municipality Amagá, Antioquia) where it was observed that the coal dust accumulated significantly in the wooden doors that in the steel arches, we proceeded to simulate different geometries of fortification and the amount of these for the purpose to determine which is the geometry that contributes to reducing the load losses. After analyzing the different scenarios, the geometry that optimizes the ventilation circuit has been called geometry Circular 2, which shows reduction in load losses of up to 14.67% compared to other geometries analyzed under the same conditions. Whit this, are proposed alternatives more efficient to optimize the ventilation circuit and ensure health and safety conditions for workers inside the mine

    Validity of the ROX index in predicting invasive mechanical ventilation requirement in pneumonia

    No full text
    8 páginasBackground The ROX index (Respiratory rate-OXygenation) has been described as a prediction tool to identify the need for invasive mechanical ventilation (IMV) in community-acquired pneumonia (CAP) with acute hypoxaemic respiratory failure treated with high-flow nasal cannula in order to avoid delay of a necessary intubation. However, its use in predicting the need for ventilatory support in hospitalised patients with CAP has not been validated. Methods This is a retrospective cohort study including subjects with CAP treated in the general ward, emergency service or intensive care unit of a third-level centre in Cundinamarca, Colombia, between January 2001 and February 2020. The ROX index was estimated as the ratio of oxygen saturation/fraction of inspired oxygen to respiratory rate. Results A total of 895 patients were included, of whom 93 (10%) required IMV. The ROX index proved to be a good predictor, presenting an area under the curve of receiver operating characteristics (AUROC) of 0.733 (95% CI 0.671 to 0.795, p<0.001) when determined by pulse oximetry and an AUROC of 0.779 (95% CI 0.699 to 0.859, p<0.001) when estimated by arterial blood gas (ABG) parameters, with an intraclass correlation of 0.894. The estimated cut-off point was 14.8; a score less than 14.8 indicates high risk of requiring IMV. Conclusion The ROX index is a good predictor of IMV in hospitalised patients with CAP. It presents good performance when calculated through pulse oximetry and can replace the one calculated by ABG

    Desempeño de la escala Pneumonia Shock para la predicción de desenlaces clínicos en neumonía

    No full text
    10 páginasIntroduction: the initial assessment of the severity of the patient with Community-Acquired Pneumonia (CAP) is a key point in deciding the site of care and for making management decisions, as well as for establishing complications and prognosis. Currently, comparative studies using the Pneumonia Shock Score vs CURB-65 are still scarce. Objective: evaluate the performance and performance of the Pneumonia Shock Score in comparison to the CURB-65 in subjects with and without severe CAP as a predictor of the need for mechanical ventilation, in-hospital mortality, and 30-day mortality. Methodology: a retrospective cohort study in subjects with a diagnosis of CAP and with all the information necessary for the complete calculation of the Pneumonia Shock Score and CURB-65. CAP was defined according to the guidelines of the American Thoracic Society / British Thoracic Society. The following outcomes were considered: in-hospital mortality and 30-day mortality, as independent variables the clinical findings, history, measurement of vital signs, laboratory findings, arterial blood gas values, and diagnostic images. Results: 1907 subjects entered the definitive analysis for the Pneumonia Shock and CURB-65 scores, 301 patients died during hospitalization and 30-day follow-up. In the present cohort, the average age was 70.5 years (SD 19.44) and 61% of the population were men. The sensitivity turned out to be higher for the CURB-65 score in in-hospital mortality (83.39%) and 30-day follow-up mortality (82.87%). The Pneumonia Shock Score has a curve of receiver operating characteristics for in-hospital and 30-day mortality of 0.748 (95% CI: 0.718-0.778, p <0.001) and 0.739 (95% CI: 0.709-0.769, p <0.001), respectively. Conclusion: The Pneumonia Shock Score has a similar performance to the CURB-65 for the prediction of mortality in patients with CAP admitted to the intensive care unit.Introducción: La evaluación inicial de la gravedad del paciente con NAC es un punto clave para decidir el sitio de cuidado y para la toma de decisiones en el manejo, así como para establecer complicaciones y pronóstico. Actualmente los estudios comparativos donde se utiliza el puntaje Pneumonia Shock Score vs CURB-65 siguen siendo escasos. Objetivo: evaluar el rendimiento y desempeño del Pneumonia Shock Score en comparación al CURB-65 en sujetos con y sin NAC grave como predictor de necesidad de ventilación mecánica, mortalidad intrahospitalaria y mortalidad a 30 días. Metodología: estudio de cohorte retrospectivo en sujetos con diagnóstico de NAC y con toda la información necesaria para el cálculo completo del Pneumonia Shock Score y CURB-65. La NAC se definió según guías de la American Thoracic Society/ British Thoracic Society. Se consideraron como desenlace la mortalidad intrahospitalaria y mortalidad a 30 días, y como variables independientes a los hallazgos clínicos, antecedentes, medición de signos vitales, hallazgos de laboratorio, valores de gases arteriales, e imágenes diagnósticas. Resultados: Ingresaron al análisis definitivo 1907 sujetos para los puntajes de Pneumonia Shock y CURB-65, 301 pacientes fallecieron durante la hospitalización y el seguimiento a 30 días. En la presente cohorte la edad promedio fue 70,5 años (DE 19,44) y el 61% de la población fueron hombres. La sensibilidad resultó ser mayor para el puntaje CURB-65 en la mortalidad intrahospitalaria (83,39%) y mortalidad a 30 días (82,87%). El Pneumonia Shock Score cuenta con una curva de características operativas del receptor para mortalidad intrahospitalaria y a 30 días de 0,748 (IC95%: 0,718-0,778, p<0,001) y de 0.739 (IC95%: 0,709-0,769, p<0,001), respectivamente. Conclusión: El Puntaje Pneumonia Shock tiene un rendimiento similar al CURB-65 para la predicción de mortalidad en pacientes con NAC que ingresan a unidad de cuidados intensivos

    Desempeño de la escala Pneumonia Shock para la predicción de desenlaces clínicos en neumonía

    No full text
    Introduction: the initial assessment of the severity of the patient with Community-Acquired Pneumonia (CAP) is a key point in deciding the site of care and for making management decisions, as well as for establishing complications and prognosis. Currently, comparative studies using the Pneumonia Shock Score vs CURB-65 are still scarce. Objective: evaluate the performance and performance of the Pneumonia Shock Score in comparison to the CURB-65 in subjects with and without severe CAP as a predictor of the need for mechanical ventilation, in-hospital mortality, and 30-day mortality. Methodology: a retrospective cohort study in subjects with a diagnosis of CAP and with all the information necessary for the complete calculation of the Pneumonia Shock Score and CURB-65. CAP was defined according to the guidelines of the American Thoracic Society / British Thoracic Society. The following outcomes were considered: in-hospital mortality and 30-day mortality, as independent variables the clinical findings, history, measurement of vital signs, laboratory findings, arterial blood gas values, and diagnostic images. Results: 1907 subjects entered the definitive analysis for the Pneumonia Shock and CURB-65 scores, 301 patients died during hospitalization and 30-day follow-up. In the present cohort, the average age was 70.5 years (SD 19.44) and 61% of the population were men. The sensitivity turned out to be higher for the CURB-65 score in in-hospital mortality (83.39%) and 30-day follow-up mortality (82.87%). The Pneumonia Shock Score has a curve of receiver operating characteristics for in-hospital and 30-day mortality of 0.748 (95% CI: 0.718-0.778, p &lt;0.001) and 0.739 (95% CI: 0.709-0.769, p &lt;0.001), respectively. Conclusion: The Pneumonia Shock Score has a similar performance to the CURB-65 for the prediction of mortality in patients with CAP admitted to the intensive care unit.Introducción: La evaluación inicial de la gravedad del paciente con NAC es un punto clave para decidir el sitio de cuidado y para la toma de decisiones en el manejo, así como para establecer complicaciones y pronóstico. Actualmente los estudios comparativos donde se utiliza el puntaje Pneumonia Shock Score vs CURB-65 siguen siendo escasos. Objetivo: evaluar el rendimiento y desempeño del Pneumonia Shock Score en comparación al CURB-65 en sujetos con y sin NAC grave como predictor de necesidad de ventilación mecánica, mortalidad intrahospitalaria y mortalidad a 30 días. Metodología:&nbsp; estudio de cohorte retrospectivo en sujetos con diagnóstico de NAC y con toda la información necesaria para el cálculo completo del Pneumonia Shock Score y CURB-65.&nbsp; La NAC se definió según&nbsp;guías de la American Thoracic Society/ British Thoracic Society. Se consideraron como desenlace la mortalidad intrahospitalaria y mortalidad a 30 días, y como variables independientes a los hallazgos clínicos, antecedentes, medición de signos vitales, hallazgos de laboratorio, valores de gases arteriales, e imágenes diagnósticas. Resultados: Ingresaron al análisis definitivo 1907 sujetos para los puntajes de Pneumonia Shock y CURB-65, 301 pacientes fallecieron durante la hospitalización y el seguimiento a 30 días. En la presente cohorte la edad promedio fue 70,5 años (DE 19,44) y el 61% de la población fueron hombres. La sensibilidad resultó ser mayor para el puntaje CURB-65 en la mortalidad intrahospitalaria (83,39%) y mortalidad a 30 días (82,87%). El Pneumonia Shock Score cuenta con una curva de características operativas del receptor para mortalidad intrahospitalaria y a 30 días de 0,748 (IC95%: 0,718-0,778, p&lt;0,001) y de 0.739 (IC95%: 0,709-0,769, p&lt;0,001), respectivamente. Conclusión: El Puntaje Pneumonia Shock tiene un rendimiento similar al CURB-65 para la predicción de mortalidad en pacientes con NAC que ingresan a unidad de cuidados intensivos
    corecore