378 research outputs found

    A Comparison of Drinking Water Contamination in Buried Slab Wells, Other Large-Diameter Wells, and Drilled Wells

    Get PDF
    This study presents the results of a statewide water well survey conducted by the Iowa Department of Public Health from 1993 to 1995 to determine whether there were statistically significant differences between well water contamination in buried slab wells, other large-diameter wells, and drilled wells. Wells were sampled for total coliform bacteria, fecal coliform bacteria, nitrate, and atrazine. Staff collected water samples and completed a site survey at each well, which included an interview with the occupant or owner and actual observations of the wellhead and surrounding area. The study included 293 buried slab wells, 287 other large-diameter wells, and 445 drilled wells. Buried slab wells were significantly less likely than other large-diameter wells to be contaminated with total coliform bacteria, fecal coliform bacteria, nitrate, and atrazine. The well type (buried slab versus other large-diameter) was a more significant variable than whether the well depth was greater than 15.2 m (50 ft) for all contaminants except for total coliform bacteria. When classified by depth (less than or equal to 15.2 m (50 ft) deep or greater than 15 .2 m (50 ft deep)), buried slab wells in each depth range were significantly less likely than other large-diameter wells to be contaminated by total coliform bacteria, fecal coliform bacteria, and nitrate. The rates of contamination for total coliform bacteria, fecal coliform bacteria, and atrazine were not significantly different for buried slab wells and drilled wells. In addition, the percentage of wells with a concentration of N03-N greater than 20 ppm or 30 ppm was not significantly different for buried slab wells and drilled wells. However, the mean concentration of N03-N (nitrate expressed as nitrogen) was significantly higher for buried slab wells compared to drilled wells, as was the percentage of wells with a concentration of N03-N greater than or equal to 3 ppm and greater than 10 ppm

    Application of OptiTrack motion capture systems in human movement analysis A systematic literature review

    Get PDF
    With the spreading of motion analysis decisions to invest into a new system demand scientific reference applications. The aim of the present systematic review is to reveal the biomechanical scientific applications of OptiTrack motion capture systems and to overview documented usage conditions and purposes. Six major scientific literature databases were used (PubMed, PubMed Central, ScienceDirect, IEEE Xplore, PLOS and Web Of Science). An OptiTrack camera system had to be used for human or biologically related motion capture. A total of 85 articles were included, 4 out of which dealt with the validation of OptiTrack systems and 81 utilized the system for biomechanical analyses. The data analysed and extracted from the system validation studies included: description of the validated and the reference system, measured features and observed errors. The data extracted from the utilizing studies also included: OptiTrack application, camera type and frequency, marker size, camera number, data processing software and the motion studied. The review offers a broad collection of biomechanical applications of OptiTrack motion capture systems as scientific references for certain motion studies. The review also summarizes findings on the accuracy of the systems. It concludes that the method descriptions of system usage are often underspecifie

    Parameter Reduction in the Frequency Analysis of Center of Pressure in Stabilometry

    Get PDF
    During postural stability evaluation frequency analyses are applied on the motion of the foot center of pressure (CoP). In this study we compared the most widely used frequency type CoP parameters (median frequency, mean power frequency, bandwidth) including some newly defined parameters (frequency range power ratios, spectral power ratio between the anteroposterior and mediolateral directions, largest CoP amplitude with the corresponding frequency). The parameters were acquired from 25 young and healthy participants. Correlation analysis was used to exclude parameters that contain redundant information. Variance analysis was used to evaluate the behavior and usability of the parameters in different stance conditions (bipedal stance with eyes open and eyes closed, single leg stance with eyes open) where the balancing capability alters. Based on our results we recommend using the largest amplitude and frequency power ratios between specified frequency bands, spectral power ratio between anteroposterior and mediolateral direction and mean power frequency

    Changes in dynamic balancing during the first six postoperative months using different surgical approaches in total hip arthroplasthy

    Get PDF
    A jelen kutatás célja annak megállapítása, hogy ultrahang-alapú, hirtelen irányváltoztatási teszttel modellezett dinamikus egyensúlyozó képesség hogyan változik a posztoperatív idĹ‘szak elsĹ‘ hat hónapjában a különbözĹ‘ (antero-lateral - AL, direkt-lateral - DL és hátsó, tokmegtartó - P) feltárás esetén. 25 DL-feltárású, 22 AL-feltárású és 25 P-feltárású csípĹ‘ízületi protézis beültetésen átesett beteg dinamikus egyensúlyozó képességét vizsgáltuk hirtelen, ultrahang-alapú irányváltoztatási teszttel a műtétet megelĹ‘zĹ‘en, majd a posztoperatív idĹ‘szak 6., 12. hetében és a 6. hónapban. A kontrollcsoportot 45 azonos korú, egészséges személy adta. A dinamikus egyensúlyozó képességet két lábon, érintett és nem-érintett oldalon történĹ‘ mérés eredményeibĹ‘l számított Lehr-féle csillapítási számmal jellemeztük.  DL- és AL feltárás esetén a Lehr-féle csillapítási szám a posztoperatív 6. héten szignifikánsan csökken a beültetés elĹ‘tt meghatározott értékekhez képest, de utána folyamatosan nĹ‘. Az érintett oldalon történĹ‘ állás közben mért értékekbĹ‘l számított Lehr-féle csillapítási szám a posztoperatív idĹ‘szak 6. hónapjában is szignifikánsan kisebb, mint a kontrollcsoport értékei. P-feltárás esetén a posztoperatív idĹ‘szakban a Lehr-féle csillapítási szám folyamatosan növekszik, és a posztoperatív idĹ‘szak 6. hónapjában megegyezik a kontrollcsoport értékeivel. A DL- és AL-feltárással műtött betegek esetén a posztoperatív idĹ‘szak elsĹ‘ hat hónapjában a dinamikus egyensúlyozó képesség folyamatosan javul, de az érintett oldal dinamikus egyensúlyozó képessége eltér a kontrollcsoportétól. A hátsó, tokmegtartásos feltárás esetén a dinamikus egyensúlyozó képesség javulása gyorsabb az elĹ‘zĹ‘ két feltárási módhoz képest, és a posztoperatív idĹ‘szak 6. hónapjára a kontrollcsoport egyensúlyozó képességétĹ‘l szignifikánsan nem tér el. A rehabilitációs protokollok összeállításánál az ízületi mozgástartományok növelése, az izmok fejlesztése mellett hangsúlyt kell fektetni a dinamikus egyensúlyozó képesség fejlesztésére is. A dinamikus egyensúlyozó képesség fejlesztésekor, illetve a segédeszközök elhagyásakor a feltárási mód okozta különbségeket figyelembe kell venni. DOI: 10.17489/biohun/2012/1/02 The aim of our study was to detect the changes in dynamic balancing –modeled with ultrasound-based sudden perturbation  test — during the first six months of the postoperative period in case of different (antero-lateral - AL, direct-lateral - DL and posterior, capsule preserving – P) surgical approaches. The dynamic balancing ability was detected with ultrasound-based sudden perturbation test before total hip arthroplasthy, and 6, 12 weeks and 6 months postoperatively in 25 patients with DL-approach, 22 patients with AL-approach and 25 patients with P-approach. The control group was formed by 45 age-matched healthy individuals. The dynamic balancing ability was characterized by the Lehr’s damping ratio that was calculated from the results of the measurements data of standing on both-, affected-, and contra-lateral lower extremity. In the sixth postoperative week, in the case of DL-, and AL approach the Lehr’s damping ratio decreased significantly comparing with the preoperative period, but after that it increased continuously. The Lehr’s damping ratio calculating from data measured during standing on affected lower extremity was significantly less as well in the sixth postoperative month, comparing to data of healthy individuals. During the postoperative period, the Lehr’s damping ratio increased continuously in case of P-approach, and in the sixth postoperative month it was equal to the control group. During the first six postoperative months, the dynamic balancing ability improved at groups operated by DL-, and AL approach, but the dynamic balancing ability of affected side differed from the control group. The improvement of dynamic balancing ability was faster at group with capsule-preserving P-approach than at the other two groups, and in the sixth postoperative month, it didn’t differ significantly from the dynamic balancing ability of the control group.  To sum it up, we can see that beside improving of muscle forces and the range of motion of hip joint, the improvement of dynamic balancing ability must be taken into consideration too when planning rehabilitation protocols and also in the case of abandonment of crutches

    Augmented Reality markereken alapuló mozgásvizsgáló rendszer validálása

    Get PDF
    A mozgásvizsgálatok iránti igény egyre jelentĹ‘sebb napjainkban, azonban a mozgásvizsgáló rendszerek magas költsége elterjedésének gátat szab. Így igény van az olcsóbb mozgásvizsgáló rendszerek fejlesztésére is. A kutatás célja egy Augmented Reality (AR) markereken alapuló mozgásvizsgáló rendszer validálása. A validálás elsĹ‘ lépése az AR markerek pozíció számítási hibájának vizsgálata OptiTrack Flex13 hagyományos mozgásrögzítĹ‘ rendszer segítségével. A vizsgálat kiterjed emberi alanyon végzett járásvizsgálat származtatott távolság-idĹ‘ és szög jellegű járásparamétereinek összehasonlítására az AR markeren alapuló és az OptiTrack mozgásvizsgáló rendszer egyidejű mérései esetén. A marker abszolút pozícióhibája visszavezethetĹ‘ a referenciarendszerrel való koordinátarendszer összerendelés véges pontosságára. A távolság-idĹ‘ paraméterek pontossága az AR markeres rendszerben kielégítĹ‘, azonban a szögjellegű járásparaméterek eltérést mutatnak, melyek az AR marker orientáció meghatározásának pontatlanságára vezethetĹ‘ek vissza. Az orientáció meghatározás továbbfejlesztésével a bemutatott AR markeres rendszer a hagyományos optikai mozgásvizsgáló rendszereknek egy olcsó alternatívája lehet.DOI: 10.17489/2018/1/0

    Does pes planus influence standing balance in elementary school-age children?

    Get PDF
    Purpose: No any research in literature was found to investigate the effect of pes planus on standingbalance in school-aged children. Any kind of change in the arches (height, flexibility) may increase thepossibility of a change in standing balance. The aim of present study is to determine the influence ofpes planus on the standing balance of school-aged children based on independent time-distance andfrequency based parameters.Materials and Methods: Subjects included 177 children (105 neutral and 72 with pes planus). The parameterswere determined from the motion of the centre of pressure (COP) on a platform equipped with pressuregauge sensors, on which the subjects were standing for 60 seconds with both feet and open eyes.Results: When comparing the neutral and pes planus groups, none of the 17 time-distance and frequencybased parameters showed any significant difference (p≥0.169).Conclusion: The results show that pes planus does not affect significantly standing balance; the differences(however not significant) between the two groups showed a poorer postural control in school-agedchildren with pes planus. It may be compensated by the increased ML dimension of the base of support

    Zebris ultrahang-alapú mozgásvizsgáló eszköz mérési pontosságának meghatározása scoliosissal kezelt gyermekek körében

    Get PDF
    A gyermekkorban kialakuló gerincdeformitások közül a leggyakoribb és legnagyobb jelentĹ‘ségű az adolescens idiopathias scoliosis (AIS), melynek utánkövetésére egyre elterjedtebbek a non-invasív eljárások. A non-invasív eljárások közül egyre nagyobb teret nyer a Zebris ultrahang-alapú gerincvizsgálat, amely alkalmas statikus helyzetben a processus spinosusok térbeli helyzetének meghatározására. A processus spinosusok térbeli helyzetébĹ‘l a gerinc sagittalis és frontalis görbületei számíthatók. Az irodalomban nem találtunk olyan kutatást, amely scoliosissal rendelkezĹ‘ gyerekek esetén elemezte a gerinc alakjának jellemzésére használt sagittalis és frontalis görbületi szögek mérésének megismétlési pontosságát. A kutatás célja Zebris ultrahang-alapú mozgásvizsgáló rendszerrel mért adatokból számított sagittalis és frontalis síkú gerincgörbületi szögek megismétlési pontosságának meghatározása általános iskolás korú, scoliosisban szenvedĹ‘ gyermekek esetén.A vizsgálatba 23 scoliosissal kezelt lány került bevonásra. A mérés során 19 (C7 és S1 közötti) processus spinosus térbeli helyzetét természetes álló egyenes testhelyzetben Zebris CMS-HS  ultrahang-alapú mozgásvizsgáló rendszerrel (Zebris Medizintechnik GmbH, Isny, Németország) rögzítettük. A vizsgálatot két orvos végezte és a mérést 3 hét múlva megismételtük. A saját fejlesztésű MATLAB-alapú programmal (MathWorks, Inc, 2016R) a 19 pontra spline módszerrel a sagittalis és a frontalis síkban egy-egy görbét illesztettünk, a görbe érintĹ‘inek felhasználásával a sagittalis és frontali síkú görbületek szögértékei számíthatók. Az ugyanazon vizsgáló által mért értékekbĹ‘l és a két vizsgáló által mért értékekbĹ‘l számított négy-négy paraméter megismétlési pontossága kiváló, melyet az alacsony standard hiba értékek is mutatnak. A legrosszabb megismétlési pontosságot a lumbalis lordosis értékének meghatározásánál találtuk.A kiváló megismétlési pontosság (ICC≥0,793, SEM≤3,869°) alapján megállapítható, hogy a módszer alkalmas scoliosisban szenvedĹ‘ gyermekek utánkövetésére is. A non-invasív Zebris ultrahang-alapú gerincvizsgáló rendszer használatával radiológiai vizsgálatok száma is csökkenthetĹ‘ a scoliosis utánkövetése esetén

    Optikai-alapú mozgásvizsgáló módszer kalibrációs pontosságának vizsgálata anatómiai pontok kijelölése esetén

    Get PDF
    A biomechanikai mozgásvizsgálatok egyik alapeszköze az optikai-alapú mozgásrögzítĹ‘ eszközök. A technológia fejlĹ‘désével egyre nĹ‘ az igény a pontosabb, kompaktabb és olcsóbb rendszerek iránt. Jelen kutatás fĹ‘ célja egy OptiTrack (NaturalPoint, Corvallis, OR, USA) rendszert alkalmazó, markercsoport mozgáskövetésen és kalibráción alapuló mozgásvizsgáló módszer pontosságának anatómiai pontok kijelölésére vonatkozó aspektusának vizsgálata. A tanulmányban 8 személy vett részt (kor: 40,8±28,8 év, tömeg: 69,4±18,1 kg, magasság: 168,1±14,8 cm), akiken két, eltérĹ‘ háttérrel (orvosi, illetve műszaki) rendelkezĹ‘ vizsgáló végzett kalibrációkat. A mérési eredményekbĹ‘l az egyes vizsgálók pontosságára jellemzĹ‘ intraobserver hibák, illetve a vizsgálók közötti eltérésekre jellemzĹ‘ interobserver hibák kerültek számításra. A rendszer megfelelĹ‘en pontosnak bizonyult, az átlagos intraobserver hiba 4,29 mm és 8,22 mm közötti, de egyes helyeken csupán 2-3 mm körüli érték. A műszaki tapasztalattal rendelkezĹ‘ vizsgáló átlagos kalibrációs hibája minden résztvevĹ‘ esetén alacsonyabb, mint az orvosi hátérrel rendelkezĹ‘. Nincs statisztikailag kimutatható kapcsolat a kalibrálások pontossága, és a résztvevĹ‘k antropometriai tulajdonságai között (kor, magasság, testsúly, testtömeg-index). Az interobserver hibák a vártnál jelentĹ‘sen nagyobbnak bizonyultak, 11,67 mm és 20,87 mm közötti résztvevĹ‘nkénti átlagos, és 65,35 mm maximális értékkel. Ezek az eltérések a különbözĹ‘ vizsgálók által végzett méréseket összehasonlíthatatlanná teszik. Az itt talált eredményeket a mérĹ‘rendszer és protokoll további fejelesztésénél érdemes szem elĹ‘tt tartani. Optical motion capture systems are one of the basic tools of biomechanical motion analyses. With the technological developments, demand for cheaper, more compact and accurate systems are on the rise. The main goal of the present study is to determine the accuracy of anatomical landmark placement in a new motion analysis method, that uses marker-cluster tracking, a calibration technique, and an OptiTrack (NaturalPoint, Corvallis, OR, USA) motion capture system. Eight subjects (age: 40.8±28.8 years, mass: 69.4±18.1 kg, height: 168.1±14.8 cm) were measured by two examiners with different practical backgrounds (one with medical, and one with technological knowledge). From the measurement results, intra-examiner errors, illustrative of the examiners accuracy, and inter-examiner errors, illustrative of the differences between examiners were determined. The motion analysis method proved to be adequately accurate, with average intra-examiner errors between 4.29 and 8.22 mm, but errors of just 2-3 mm were achieved in cases. The results showed that, the average error of the examiner with technological background was lower compared to the examiner with medical background for every subject. No statistically significant connection was found between subject’s anthropometric properties (age, mass, height and body-mass index) and calibration accuracy. However, it was found that inter-examiner errors much larger than expected, with average values between 11.67 and 20.87 mm, with a maximum of 65.35 mm. These errors render measurements between examiners incomparable. These findings should be considered during further development of the measurement protocol. DOI: 10.17489/2018/1/0
    • …
    corecore