49 research outputs found

    Incentives and Redistribution in Homogeneous Bike-Sharing Systems with Stations of Finite Capacity

    Get PDF
    Bike-sharing systems are becoming important for urban transportation. In such systems, users arrive at a station, take a bike and use it for a while, then return it to another station of their choice. Each station has a finite capacity: it cannot host more bikes than its capacity. We propose a stochastic model of an homogeneous bike-sharing system and study the effect of users random choices on the number of problematic stations, i.e., stations that, at a given time, have no bikes available or no available spots for bikes to be returned to. We quantify the influence of the station capacities, and we compute the fleet size that is optimal in terms of minimizing the proportion of problematic stations. Even in a homogeneous city, the system exhibits a poor performance: the minimal proportion of problematic stations is of the order of (but not lower than) the inverse of the capacity. We show that simple incentives, such as suggesting users to return to the least loaded station among two stations, improve the situation by an exponential factor. We also compute the rate at which bikes have to be redistributed by trucks to insure a given quality of service. This rate is of the order of the inverse of the station capacity. For all cases considered, the fleet size that corresponds to the best performance is half of the total number of spots plus a few more, the value of the few more can be computed in closed-form as a function of the system parameters. It corresponds to the average number of bikes in circulation

    Incentives and redistribution in homogeneous bike-sharing systems with stations of finite capacity

    No full text
    International audienceBike-sharing systems are becoming important for urban transportation. In these systems, users arrive at a station, pick up a bike, use it for a while, and then return it to another station of their choice. Each station has a finite capacity: it cannot host more bikes than its capacity. We propose a stochastic model of an homogeneous bike-sharing system and study the effect of the randomness of user choices on the number of problematic stations, i.e., stations that, at a given time, have no bikes available or no available spots for bikes to be returned to. We quantify the influence of the station capacities, and we compute the fleet size that is optimal in terms of minimizing the proportion of problematic stations. Even in a homogeneous city, the system exhibits a poor performance: the minimal proportion of problematic stations is of the order of the inverse of the capacity. We show that simple incentives, such as suggesting users to return to the least loaded station among two stations, improve the situation by an exponential factor. We also compute the rate at which bikes have to be redistributed by trucks for a given quality of service. This rate is of the order of the inverse of the station capacity. For all cases considered, the fleet size that corre-sponds to the best performance is half of the total number of spots plus a few more, the value of the few more can be computed in closed-form as a function of the system parameters. It corresponds to the average number of bikes in circulation

    Validation of previously identified serum biomarkers for breast cancer with SELDI-TOF MS: a case control study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Serum protein profiling seems promising for early detection of breast cancer. However, the approach is also criticized, partly because of difficulties in validating discriminatory proteins. This study's aim is to validate three proteins previously reported to be discriminative between breast cancer cases and healthy controls. These proteins had been identified as a fragment of inter-alpha trypsin inhibitor H4 (4.3 kDa), C-terminal-truncated form of C3a des arginine anaphylatoxin (8.1 kDa) and C3a des arginine anaphylatoxin (8.9 kDa).</p> <p>Methods</p> <p>Serum protein profiles of 48 breast cancer patients and 48 healthy controls were analyzed with surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS). Differences in protein intensity between breast cancer cases and controls were measured with the Mann-Whitney U test and adjusted for confounding in a multivariate logistic regression model.</p> <p>Results</p> <p>Four peaks, with mass-to-charge ratio (<it>m/z</it>) 4276, 4292, 8129 and 8941, were found that were assumed to represent the previously reported proteins. <it>M/</it>z 4276 and 4292 were statistically significantly decreased in breast cancer cases compared to healthy controls (p < 0.001). M/<it>z </it>8941 was decreased in breast cancer cases (p < 0.001) and <it>m/z </it>8129 was not related with breast cancer (p = 0.87). Adjustment for sample preparation day, sample storage duration and age did not substantially alter results.</p> <p>Conclusion</p> <p><it>M/z </it>4276 and 4292 both represented the previously reported 4.3 kDa protein and were both decreased in breast cancer patients, which is in accordance with the results of most previous studies. <it>M/z </it>8129 was in contrast with previous studies not related with breast cancer. Remarkably, <it>m/z </it>8941 was decreased in breast cancer cases whereas in previous studies it was increased. Differences in patient populations and pre-analytical sample handling could have contributed to discrepancies. Further research is needed before we can conclude on the relevance of these proteins as breast cancer biomarkers.</p

    Comparing the old and new generation SELDI-TOF MS: implications for serum protein profiling

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although the PBS-IIc SELDI-TOF MS apparatus has been extensively used in the search for better biomarkers, issues have been raised concerning the semi-quantitative nature of the technique and its reproducibility. To overcome these limitations, a new SELDI-TOF MS instrument has been introduced: the PCS 4000 series. Changes in this apparatus compared to the older one are a.o. an increased dynamic range of the detector, an adjusted configuration of the detector sensitivity, a raster scan that ensures more complete desorption coverage and an improved detector attenuation mechanism. In the current study, we evaluated the performance of the old PBS-IIc and new PCS 4000 series generation SELDI-TOF MS apparatus.</p> <p>Methods</p> <p>To this end, two different sample sets were profiled after which the same ProteinChip arrays were analysed successively by both instruments. Generated spectra were analysed by the associated software packages. The performance of both instruments was evaluated by assessment of the number of peaks detected in the two sample sets, the biomarker potential and reproducibility of generated peak clusters, and the number of peaks detected following serum fractionation.</p> <p>Results</p> <p>We could not confirm the claimed improved performance of the new PCS 4000 instrument, as assessed by the number of peaks detected, the biomarker potential and the reproducibility. However, the PCS 4000 instrument did prove to be of superior performance in peak detection following profiling of serum fractions.</p> <p>Conclusion</p> <p>As serum fractionation facilitates detection of low abundant proteins through reduction of the dynamic range of serum proteins, it is now increasingly applied in the search for new potential biomarkers. Hence, although the new PCS 4000 instrument did not differ from the old PBS-IIc apparatus in the analysis of crude serum, its superior performance after serum fractionation does hold promise for improved biomarker detection and identification.</p

    Searching for early breast cancer biomarkers by serum protein profiling of pre-diagnostic serum; a nested case-control study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Serum protein profiles have been investigated frequently to discover early biomarkers for breast cancer. So far, these studies used biological samples collected <it>at </it>or <it>after </it>diagnosis. This may limit these studies' value in the search for cancer biomarkers because of the often advanced tumor stage, and consequently risk of reverse causality. We present for the first time pre-diagnostic serum protein profiles in relation to breast cancer, using the Prospect-EPIC (European Prospective Investigation into Cancer and nutrition) cohort.</p> <p>Methods</p> <p>In a nested case-control design we compared 68 women diagnosed with breast cancer within three years after enrollment, with 68 matched controls for differences in serum protein profiles. All samples were analyzed with SELDI-TOF MS (surface enhanced laser desorption/ionization time-of-flight mass spectrometry). In a subset of 20 case-control pairs, the serum proteome was identified and relatively quantified using isobaric Tags for Relative and Absolute Quantification (iTRAQ) and online two-dimensional nano-liquid chromatography coupled with tandem MS (2D-nanoLC-MS/MS).</p> <p>Results</p> <p>Two SELDI-TOF MS peaks with m/z 3323 and 8939, which probably represent doubly charged apolipoprotein C-I and C3a des-arginine anaphylatoxin (C3a<sub>desArg</sub>), were higher in pre-diagnostic breast cancer serum (p = 0.02 and p = 0.06, respectively). With 2D-nanoLC-MS/MS, afamin, apolipoprotein E and isoform 1 of inter-alpha trypsin inhibitor heavy chain H4 (ITIH4) were found to be higher in pre-diagnostic breast cancer (p < 0.05), while alpha-2-macroglobulin and ceruloplasmin were lower (p < 0.05). C3a<sub>desArg </sub>and ITIH4 have previously been related to the presence of symptomatic and/or mammographically detectable breast cancer.</p> <p>Conclusions</p> <p>We show that serum protein profiles are already altered up to three years before breast cancer detection.</p

    Comparison between B·R·A·H·M·S PCT direct, a new sensitive point-of-care testing device for rapid quantification of procalcitonin in emergency department patients and established reference methods - a prospective multinational trial

    Get PDF
    Background: Procalcitonin (PCT) is increasingly being used for the diagnostic and prognostic work up of patients with suspected infections in the emergency department (ED). Recently, B·R·A·H·M·S PCT direct, the first high sensitive point-of-care test (POCT), has been developed for fast PCT measurement on capillary or venous blood samples. Methods: This is a prospective, international comparison study conducted in three European EDs. Consecutive patients with suspicion of bacterial infection were included. Duplicate determination of PCT was performed in capillary (fingertip) and venous whole blood (EDTA), and compared to the reference method. The diagnostic accuracy was evaluated by correlation and concordance analyses. Results: Three hundred and three patients were included over a 6-month period (60.4% male, median age 65.2 years). The correlation between capillary or venous whole blood and the reference method was excellent: r2=0.96 and 0.97, sensitivity 88.1% and 93.0%, specificity 96.5% and 96.8%, concordance 93% and 95%, respectively at a 0.25 μg/L threshold. No significant bias was observed (-0.04 and -0.02 for capillary and venous whole blood) although there were 6.8% and 5.1% outliers, respectively. B·R·A·H·M·S PCT direct had a shorter time to result as compared to the reference method (25 vs. 144 min, difference 119 min, 95% CI 110-134 min, p<0.0001). Conclusions: This study found a high diagnostic accuracy and a faster time to result of B·R·A·H·M·S PCT direct in the ED setting, allowing shortening time to therapy and a more wide-spread use of PCT

    Comparison of normalisation methods for surface-enhanced laser desorption and ionisation (SELDI) time-of-flight (TOF) mass spectrometry data

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Mass spectrometry for biological data analysis is an active field of research, providing an efficient way of high-throughput proteome screening. A popular variant of mass spectrometry is SELDI, which is often used to measure sample populations with the goal of developing (clinical) classifiers. Unfortunately, not only is the data resulting from such measurements quite noisy, variance between replicate measurements of the same sample can be high as well. Normalisation of spectra can greatly reduce the effect of this technical variance and further improve the quality and interpretability of the data. However, it is unclear which normalisation method yields the most informative result.</p> <p>Results</p> <p>In this paper, we describe the first systematic comparison of a wide range of normalisation methods, using two objectives that should be met by a good method. These objectives are minimisation of inter-spectra variance and maximisation of signal with respect to class separation. The former is assessed using an estimation of the coefficient of variation, the latter using the classification performance of three types of classifiers on real-world datasets representing two-class diagnostic problems. To obtain a maximally robust evaluation of a normalisation method, both objectives are evaluated over multiple datasets and multiple configurations of baseline correction and peak detection methods. Results are assessed for statistical significance and visualised to reveal the performance of each normalisation method, in particular with respect to using no normalisation. The normalisation methods described have been implemented in the freely available MASDA R-package.</p> <p>Conclusion</p> <p>In the general case, normalisation of mass spectra is beneficial to the quality of data. The majority of methods we compared performed significantly better than the case in which no normalisation was used. We have shown that normalisation methods that scale spectra by a factor based on the dispersion (e.g., standard deviation) of the data clearly outperform those where a factor based on the central location (e.g., mean) is used. Additional improvements in performance are obtained when these factors are estimated locally, using a sliding window within spectra, instead of globally, over full spectra. The underperforming category of methods using a globally estimated factor based on the central location of the data includes the method used by the majority of SELDI users.</p

    Postoperative serum proteomic profiles may predict recurrence-free survival in high-risk primary breast cancer

    Get PDF
    Item does not contain fulltextPURPOSE: Better breast cancer prognostication may improve selection of patients for adjuvant therapy. We conducted a retrospective longitudinal study in which we investigated sera of high-risk primary breast cancer patients, to search for proteins predictive of recurrence-free survival. METHODS: Sera of 82 breast cancer patients obtained after surgery, but prior to the administration of adjuvant therapy, were fractionated using anion-exchange chromatography, to facilitate the detection of the low-abundant serum peptides. Selected fractions were subsequently analysed by surface-enhanced laser desorption/ionisation time-of-flight mass spectrometry (SELDI-TOF MS), and the resulting protein profiles were searched for prognostic markers by appropriate bioinformatics tools. RESULTS: Four peak clusters (i.e. m/z 3073, m/z 3274, m/z 4405 and m/z 7973) were found to bear significant prognostic value (P </= 0.01). The m/z 3274 candidate marker was structurally identified as inter-alpha-trypsin inhibitor heavy chain 4 fragment(658-688) in serum. Except for the m/z 7973 peak cluster, these peaks remained independently associated with recurrence-free survival upon multivariate Cox regression analysis, including clinical parameters of known prognostic value in this study population. CONCLUSION: Investigation of the postoperative serum proteome by, e.g., anion-exchange fractionation followed by SELDI-TOF MS analysis is promising for the detection of novel prognostic factors. However, regarding the rather limited study population, validation of these results by analysis of independent study populations is warranted to assess the true clinical applicability of discovered prognostic markers. In addition, structural identification of the other markers will aid in elucidation of their role in breast cancer prognosis, as well as enable development of absolute quantitative assays

    Exhaustion of bacteria-specific CD4 T cells and microbial translocation in common variable immunodeficiency disorders.

    Get PDF
    In the present study, we have investigated the functional profile of CD4 T cells from patients with common variable immunodeficiency (CVID), including production of cytokines and proliferation in response to bacteria and virus-derived antigens. We show that the functional impairment of CD4 T cells, including the reduced capacity to proliferate and to produce IFN-γ and IL-2, was restricted to bacteria-specific and not virus-specific CD4 T cells. High levels of endotoxins were found in the plasma of patients with CVID, suggesting that CD4 T cell dysfunction might be caused by bacterial translocation. Of note, endotoxemia was associated with significantly higher expression of programmed death 1 (PD-1) on CD4 T cells. The blockade of the PD-1-PD-L1/2 axis in vitro restored CD4 T cell proliferation capacity, thus indicating that PD-1 signaling negatively regulates CD4 T cell functions. Finally, we showed that intravenous immunoglobulin G (IVIG) treatment significantly reduced endotoxemia and the percentage of PD-1(+) CD4 T cells, and restored bacteria-specific CD4 T cell cytokine production and proliferation. In conclusion, the present study demonstrates that the CD4 T cell exhaustion and functional impairment observed in CVID patients is associated with bacterial translocation and that IVIG treatment resolves bacterial translocation and restores CD4 T cell functions
    corecore