34 research outputs found

    The new challenges of machining Ceramic Matrix Composites (CMCs): review of surface integrity

    Get PDF
    Ceramic Matrix Composites (CMCs) are currently an increasing material choice for several high value and safety-critical components, fact that has recently originated the need of understanding the effect of several machining processes. Due to the complex nature of CMCs - i.e. heterogeneous structure, anisotropic thermal and mechanical behaviour and generally the hard nature of at least one of the constituents (e.g. fibre or matrix) - machining become extremely challenging as the process can yield high mechanical and thermal loads. Furthermore, the orthotropic, brittle and heterogeneous nature of CMCs result in different material removal mechanisms which lead to unique surface defects. Hence, this review paper attempts to provide an informative literature survey of the research done in the field of conventional and non-conventional machining of CMCs with a main focus on critically evaluate how different machining techniques affect the machined surfaces. This is achieved by exploring and recollecting the different material characterisation techniques currently used to observe and quantify the mechanical and thermal surface and subsurface damages and highlight their governing removal mechanisms

    Temperatura neutral y rangos de confort térmico para exteriores, período cálido en clima cálido seco

    Get PDF
    El estimar las temperaturas de confort térmico en espacios exteriores permite obtener información que sirve de base para generar propuestas de diseño, cuyas condiciones ambientales propicien el confort térmico de los usuarios. Se presenta la estimación de temperatura neutral y rangos de confort térmico para espacios exteriores de un parque recreativo, en el período cálido en un clima desértico. El estudio fue desarrollado en Mexicali, Baja California, México. Se diseñó un cuestionario basado en la escala de sensaciones térmicas de ISO 10551, se midieron temperatura de bulbo seco, temperatura de globo gris, humedad relativa y velocidad de viento. Se aplicaron 822 encuestas en julio y agosto del 2008. Se estimaron temperatura neutra y rangos de confort con el método de medias por intervalo de sensación térmica. El análisis se hizo para tres niveles de actividad: pasiva, moderada e intensa y uno combinado con los tres niveles. Los valores de temperatura neutra obtenidos son aproximadamente simétricos con respecto a sus rangos de confort térmico. Las temperaturas neutras obtenidas muestran que los sujetos en actividad intensa, con práctica periódica de ejercicio y hábitos apropiados a las condiciones de clima, tienen una temperatura de confort térmico similar a aquellos con actividad pasiva

    On modelling coolant penetration into the microchannels at the tool-workpiece interface

    Get PDF
    A network of microchannels is formed at the interface between the cutting tool and the workpiece during machining due to their rough surface structures. The penetration of coolant into these microchannels has a great effect on the machined surface quality by changing the frictional behaviour and heat transfer characteristics of the interfaces. Most of the present studies focus on the macroscopic coolant delivery process but the mechanism of the microscopic penetration phenomena in the channels at the interface remains unclear. Thus, this study proposes a multi-scale and multi-phase comprehensive theoretical model by combining the machining process, coolant flowing in microchannels and lubrication process, to analyse the coolant transportation in the microchannels and investigate its lubrication effects and the friction mechanisms at the interface between the tool and the workpiece. Then, an orthogonal turning testing of Inconel 718 is designed to verify the proposed model. The cooling and lubrication effect of coolant in the microchannels on the reduction of tool wear, contact length, cutting force and temperature has been demonstrated. And the improvement of chip fragment and microstructure has also been revealed

    A personalized intervention to prevent depression in primary care: cost-effectiveness study nested into a clustered randomized trial

    Get PDF
    Background: Depression is viewed as a major and increasing public health issue, as it causes high distress in the people experiencing it and considerable financial costs to society. Efforts are being made to reduce this burden by preventing depression. A critical component of this strategy is the ability to assess the individual level and profile of risk for the development of major depression. This paper presents the cost-effectiveness of a personalized intervention based on the risk of developing depression carried out in primary care, compared with usual care. Methods: Cost-effectiveness analyses are nested within a multicentre, clustered, randomized controlled trial of a personalized intervention to prevent depression. The study was carried out in 70 primary care centres from seven cities in Spain. Two general practitioners (GPs) were randomly sampled from those prepared to participate in each centre (i.e. 140 GPs), and 3326 participants consented and were eligible to participate. The intervention included the GP communicating to the patient his/her individual risk for depression and personal risk factors and the construction by both GPs and patients of a psychosocial programme tailored to prevent depression. In addition, GPs carried out measures to activate and empower the patients, who also received a leaflet about preventing depression. GPs were trained in a 10- to 15-h workshop. Costs were measured from a societal and National Health care perspective. Qualityadjustedlife years were assessed using the EuroQOL five dimensions questionnaire. The time horizon was 18 months. Results: With a willingness-to-pay threshold of (sic)10, 000 ((sic)8568) the probability of cost-effectiveness oscillated from 83% (societal perspective) to 89% (health perspective). If the threshold was increased to (sic)30, 000 ((sic)25, 704), the probability of being considered cost-effective was 94% (societal perspective) and 96%, respectively (health perspective). The sensitivity analysis confirmed these results. Conclusions: Compared with usual care, an intervention based on personal predictors of risk of depression implemented by GPs is a cost-effective strategy to prevent depression. This type of personalized intervention in primary care should be further developed and evaluated

    Allogeneic Stem Cell Transplantation in Mature T Cell and Natural Killer/T Neoplasias: A Registry Study from Spanish GETH/GELTAMO Centers

    Get PDF
    Despite advances in understanding the biology of mature T and natural killer (NK)/T cell neoplasia, current therapies, even the most innovative ones, are still far from ensuring its cure. The only treatment to date that has been shown to control aggressive T cell neoplasms in the long term is allogeneic stem cell transplantation (alloSCT). We aim to report the results of alloSCT for advanced mature T and NK/T neoplasias performed in centers from our national GELTAMO/GETH (Grupo Español de Linfoma y Trasplante de Médula Ósea/Grupo Español de Trasplante Hematopoyético y Terapia Celular) over the past 25 years. As a secondary objective, we analyzed the results of alloSCT from haploidentical donors. We performed a retrospective analysis of all patients who received an alloSCT in Spanish centers (n = 201) from September 1995 to August 2018. The 2-year overall survival (OS) and disease-free survival (DFS) were 65.5% and 58.2%, respectively. The univariate for OS and DFS showed statistically different hazard ratios for conditioning intensity, response pre-alloSCT, comorbidity index, donor/receptor cytomegalovirus status and Eastern Cooperative Oncology Group (ECOG) pre-alloSCT, but only a better ECOG pre-alloSCT remained significant in the multivariate analysis. There was an increased incidence of relapse in those patients who did not develop chronic graft-versus-host disease (GVHD) and an increased risk of death in those developing moderate to severe acute GVHD. The 1-year nonrelapse mortality was 21.9% and was mainly due to GVHD (30%) and bacterial infections (17%). When comparing unrelated donors with haploidentical donors, we found similar results in terms of OS and DFS. There was, however, a reduction of acute GVHD in the haploidentical group (P = .04) and trend to a reduction of chronic GVHD. In conclusion, alloSCT is the only curative option for most aggressive T cell neoplasias. Haploidentical donors offer similar results to related donors in terms of survival with a reduction of acute GVHD

    Risk factors and outcome of COVID-19 in patients with hematological malignancies

    Get PDF
    Background: Prognostic factors of poor outcome in patients with hematological malignancies and COVID-19 are poorly defned. Patients and methods: This was a Spanish transplant group and cell therapy (GETH) multicenter retrospective observational study, which included a large cohort of blood cancer patients with laboratory-confrmed SARS-CoV-2 infection through PCR assays from March 1st 2020 to May 15th 2020. Results: We included 367 pediatric and adult patients with hematological malignancies, including recipients of autologous (ASCT) (n=58) or allogeneic stem cell transplantation (allo-SCT) (n=65) from 41 hospitals in Spain. Median age of patients was 64 years (range 1-93.8). Recipients of ASCT and allo-SCT showed lower mortality rates (17% and 18%, respectively) compared to non-SCT patients (31%) (p=0.02). Prognostic factors identifed for day 45 overall mortality (OM) by logistic regression multivariate analysis included age>70 years [odds ratio (OR) 2.1, 95% con‑ fdence interval (CI) 1.2-3.8, p=0.011]; uncontrolled hematological malignancy (OR 2.9, 95% CI 1.6-5.2, p20 mg/dL (OR 3.3, 95% CI 1.7-6.4, p<0.0001). In multivariate analysis of 216 patients with very severe COVID-19, treatment with azithromycin or low dose corticosteroids was associated with lower OM (OR 0.42, 95% CI 0.2-0.89 and OR 0.31, 95% CI 0.11-0.87, respectively, p=0.02) whereas the use of hidroxycloroquine did not show signifcant improvement in OM (OR 0.64, 95% CI 0.37-1.1, P=0.1). Conclusions: In most patients with hematological malignancies COVID-19 mortality was directly driven by older age, disease status, performance status, as well as by immune (neutropenia) parameters and level of infammation (high CRP). Use of azithromycin and low dose corticosteroids may be of value in very severe COVID-19

    Overview of recent TJ-II stellarator results

    Get PDF
    The main results obtained in the TJ-II stellarator in the last two years are reported. The most important topics investigated have been modelling and validation of impurity transport, validation of gyrokinetic simulations, turbulence characterisation, effect of magnetic configuration on transport, fuelling with pellet injection, fast particles and liquid metal plasma facing components. As regards impurity transport research, a number of working lines exploring several recently discovered effects have been developed: the effect of tangential drifts on stellarator neoclassical transport, the impurity flux driven by electric fields tangent to magnetic surfaces and attempts of experimental validation with Doppler reflectometry of the variation of the radial electric field on the flux surface. Concerning gyrokinetic simulations, two validation activities have been performed, the comparison with measurements of zonal flow relaxation in pellet-induced fast transients and the comparison with experimental poloidal variation of fluctuations amplitude. The impact of radial electric fields on turbulence spreading in the edge and scrape-off layer has been also experimentally characterized using a 2D Langmuir probe array. Another remarkable piece of work has been the investigation of the radial propagation of small temperature perturbations using transfer entropy. Research on the physics and modelling of plasma core fuelling with pellet and tracer-encapsulated solid-pellet injection has produced also relevant results. Neutral beam injection driven Alfvénic activity and its possible control by electron cyclotron current drive has been examined as well in TJ-II. Finally, recent results on alternative plasma facing components based on liquid metals are also presentedThis work has been carried out within the framework of the EUROfusion Consortium and has received funding from the Euratom research and training programme 2014–2018 under Grant Agreement No. 633053. It has been partially funded by the Ministerio de Ciencia, Inovación y Universidades of Spain under projects ENE2013-48109-P, ENE2015-70142-P and FIS2017-88892-P. It has also received funds from the Spanish Government via mobility grant PRX17/00425. The authors thankfully acknowledge the computer resources at MareNostrum and the technical support provided by the Barcelona S.C. It has been supported as well by The Science and Technology Center in Ukraine (STCU), Project P-507F

    Canagliflozin and renal outcomes in type 2 diabetes and nephropathy

    Get PDF
    BACKGROUND Type 2 diabetes mellitus is the leading cause of kidney failure worldwide, but few effective long-term treatments are available. In cardiovascular trials of inhibitors of sodium–glucose cotransporter 2 (SGLT2), exploratory results have suggested that such drugs may improve renal outcomes in patients with type 2 diabetes. METHODS In this double-blind, randomized trial, we assigned patients with type 2 diabetes and albuminuric chronic kidney disease to receive canagliflozin, an oral SGLT2 inhibitor, at a dose of 100 mg daily or placebo. All the patients had an estimated glomerular filtration rate (GFR) of 30 to &lt;90 ml per minute per 1.73 m2 of body-surface area and albuminuria (ratio of albumin [mg] to creatinine [g], &gt;300 to 5000) and were treated with renin–angiotensin system blockade. The primary outcome was a composite of end-stage kidney disease (dialysis, transplantation, or a sustained estimated GFR of &lt;15 ml per minute per 1.73 m2), a doubling of the serum creatinine level, or death from renal or cardiovascular causes. Prespecified secondary outcomes were tested hierarchically. RESULTS The trial was stopped early after a planned interim analysis on the recommendation of the data and safety monitoring committee. At that time, 4401 patients had undergone randomization, with a median follow-up of 2.62 years. The relative risk of the primary outcome was 30% lower in the canagliflozin group than in the placebo group, with event rates of 43.2 and 61.2 per 1000 patient-years, respectively (hazard ratio, 0.70; 95% confidence interval [CI], 0.59 to 0.82; P=0.00001). The relative risk of the renal-specific composite of end-stage kidney disease, a doubling of the creatinine level, or death from renal causes was lower by 34% (hazard ratio, 0.66; 95% CI, 0.53 to 0.81; P&lt;0.001), and the relative risk of end-stage kidney disease was lower by 32% (hazard ratio, 0.68; 95% CI, 0.54 to 0.86; P=0.002). The canagliflozin group also had a lower risk of cardiovascular death, myocardial infarction, or stroke (hazard ratio, 0.80; 95% CI, 0.67 to 0.95; P=0.01) and hospitalization for heart failure (hazard ratio, 0.61; 95% CI, 0.47 to 0.80; P&lt;0.001). There were no significant differences in rates of amputation or fracture. CONCLUSIONS In patients with type 2 diabetes and kidney disease, the risk of kidney failure and cardiovascular events was lower in the canagliflozin group than in the placebo group at a median follow-up of 2.62 years

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Towards the understanding the effect of surface integrity on the fatigue performance of silicon carbide particle reinforced aluminium matrix composites

    No full text
    The fatigue performance of metal matrix composites (MMCs) is highly related to their surface integrity due to the intensive tool-particle interactions and metallographic alterations of matrix, especially under extreme cutting parameters, which could largely result in surface morphologic defects and subsurface damage on the components. Although the fatigue performance of bulk MMCs has been extensively studied, the influence of machining-induced surface anomalies on the fatigue failure mechanism still needs to be understood. This paper investigates the effect of two distinct surface integrities induced by two cutting regimes (ductile, and semi-brittle regime) on the fatigue performance of MMCs. The ductile and semi-brittle regime were represented by different surface integrities regarding the particle behaviours and their effect on the mechanical and metallographic alterations of matrix materials. In-depth analysis in terms of surface topography, subsurface damage, and residual stresses of the machined workpieces has been carried out before the three-point bending fatigue test. The results showed that the samples machined by finish milling (very low feed – semi-brittle regime) unexpectedly presented lower fatigue lives compared to the rough-milled counterparts (high feed – ductile regime), despite the former displayed compressive residual stress and lower surface roughness. It was found that the particles have pronounced influence on the fatigue performance in two different ways: under low cycle fatigue, the particles were prone to be fractured by the high stress applied (which accelerated the formation of crack initiations and therefore shortened the fatigue life), while under high cycle fatigue, the reinforcement particles were not fractured and instead they could inhibit the crack growth up to some extent. Therefore, fatigue lives of the rough-milled samples (high feed – ductile regime) were enhanced due to the retardation of reinforcement particles
    corecore