21 research outputs found

    Automatic measurement of departing times in smartphone alerting systems: A pilot study

    Get PDF
    Aim Smartphone alerting systems (SAS) alert volunteers in close vicinity of suspected out-of-hospital cardiac arrest. Some systems use sophisticated algorithms to select those who will probably arrive first. Precise estimation of departing times and travel times may help to further improve algorithms. We developed a global positioning system (GPS) based method for automatic measurements of departing times. The aim of this pilot study was to evaluate feasibility and precision of the method. Methods Region of Lifesavers alerting app (iOS/ Android, version 3.0, FirstAED ApS, Denmark) was used in this study. 27 experiments were performed with 9 students, who were instructed to stay in their flats during the study days. A geofence was set for each alarm in the alerting system with a radius of 10 m (8 cases), 15 m (10 cases), and 20 m (9 cases) around the GPS position at which the alarm was accepted in the app. The system logged responders as being departed when the smartphone position was registered outside the geofence. The students were instructed to manually start a stopwatch at the time of the alert and to stop the stopwatch once they had entered the street in front of their flat. Results The median difference between automatically and manually retrieved times were −16 seconds [interquartile range IQR 50 seconds] (geofence 10 m), 30 seconds [IQR 25 seconds] (15 m), and 20 seconds [IQR 13 seconds] (20 m), respectively. The 20 m geofence was associated with the smallest interquartile range. Conclusion Departing times of volunteer responders in SAS can be retrieved automatically using GPS and a geofence

    Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries.

    Get PDF
    BACKGROUND: As global initiatives increase patient access to surgical treatments, there remains a need to understand the adverse effects of surgery and define appropriate levels of perioperative care. METHODS: We designed a prospective international 7-day cohort study of outcomes following elective adult inpatient surgery in 27 countries. The primary outcome was in-hospital complications. Secondary outcomes were death following a complication (failure to rescue) and death in hospital. Process measures were admission to critical care immediately after surgery or to treat a complication and duration of hospital stay. A single definition of critical care was used for all countries. RESULTS: A total of 474 hospitals in 19 high-, 7 middle- and 1 low-income country were included in the primary analysis. Data included 44 814 patients with a median hospital stay of 4 (range 2-7) days. A total of 7508 patients (16.8%) developed one or more postoperative complication and 207 died (0.5%). The overall mortality among patients who developed complications was 2.8%. Mortality following complications ranged from 2.4% for pulmonary embolism to 43.9% for cardiac arrest. A total of 4360 (9.7%) patients were admitted to a critical care unit as routine immediately after surgery, of whom 2198 (50.4%) developed a complication, with 105 (2.4%) deaths. A total of 1233 patients (16.4%) were admitted to a critical care unit to treat complications, with 119 (9.7%) deaths. Despite lower baseline risk, outcomes were similar in low- and middle-income compared with high-income countries. CONCLUSIONS: Poor patient outcomes are common after inpatient surgery. Global initiatives to increase access to surgical treatments should also address the need for safe perioperative care. STUDY REGISTRATION: ISRCTN5181700

    Avatar-based versus conventional vital sign display in a central monitor for monitoring multiple patients: a multicenter computer-based laboratory study

    Get PDF
    Background: Maintaining adequate situation awareness is crucial for patient safety. Previous studies found that the use of avatar-based monitoring (Visual Patient Technology) improved the perception of vital signs compared to conventional monitoring showing numerical and waveform data; and was further associated with a reduction of perceived workload. In this study, we aimed to evaluate the effectiveness of Visual Patient Technology on perceptive performance and perceived workload when monitoring multiple patients at the same time, such as in central station monitors in intensive care units or operating rooms. Methods: A prospective, within-subject, computer-based laboratory study was performed in two tertiary care hospitals in Switzerland in 2018. Thirty-eight physician and nurse anesthetists volunteered for the study. The participants were shown four different central monitor scenarios in sequence, where each scenario displayed two critical and four healthy patients simultaneously for 10 or 30 s. After each scenario, participants had to recall the vital signs of the critical patients. Perceived workload was assessed with the National Aeronautics and Space Administration Task-Load-Index (NASA TLX) questionnaire. Results: In the 10-s scenarios, the median number of remembered vital signs significantly improved from 7 to 11 using avatar-based versus conventional monitoring with a mean of differences of 4 vital signs, 95% confidence interval (CI) 2 to 6, p < 0.001. At the same time, the median NASA TLX scores were significantly lower for avatar-based monitoring (67 vs. 77) with a mean of differences of 6 points, 95% CI 0.5 to 11, p = 0.034. In the 30-s scenarios, vital sign perception and workload did not differ significantly. Conclusions: In central monitor multiple patient monitoring, we found a significant improvement of vital sign perception and reduction of perceived workload using Visual Patient Technology, compared to conventional monitoring. The technology enabled improved assessment of patient status and may, thereby, help to increase situation awareness and enhance patient safety

    The Automated External Defibrillator : Heterogeneity of Legislation, Mapping and Use across Europe. New Insights from the ENSURE Study

    Get PDF
    Introduction: The rapid use of an automated external defibrillator (AED) is crucial for increased survival after an out-of-hospital cardiac arrest (OHCA). Many factors could play a role in limiting the chance of an AED use. We aimed to verify the situation regarding AED legislation, the AED mapping system and first responders (FRs) equipped with an AED across European countries. Methods: We performed a survey across Europe entitled "European Study about AED Use by Lay Rescuers " (ENSURE), asking the national coordinators of the European Registry of Cardiac Arrest (EuReCa) program to complete it. Results: Nineteen European countries replied to the survey request for a population covering 128,297,955 inhabitants. The results revealed that every citizen can use an AED in 15 countries whereas a training certificate was required in three countries. In one country, only EMS personnel were allowed to use an AED. An AED mapping system and FRs equipped with an AED were available in only 11 countries. The AED use rate was 12-59% where AED mapping and FR systems were implemented, which was considerably higher than in other countries (0-7.9%), reflecting the difference in OHCA survival. Conclusions: Our survey highlighted a heterogeneity in AED legislation, AED mapping systems and AED use in Europe, which was reflected in different AED use and survival.Peer reviewe

    The automated external defibrillator: Heterogeneity of legislation, mapping and use across europe. new insights from the ensure study

    No full text
    Introduction: The rapid use of an automated external defibrillator (AED) is crucial for increased survival after an out-of-hospital cardiac arrest (OHCA). Many factors could play a role in limiting the chance of an AED use. We aimed to verify the situation regarding AED legislation, the AED mapping system and first responders (FRs) equipped with an AED across European countries. Methods: We performed a survey across Europe entitled “European Study about AED Use by Lay Rescuers” (ENSURE), asking the national coordinators of the European Registry of Cardiac Arrest (EuReCa) program to complete it. Results: Nineteen European countries replied to the survey re-quest for a population covering 128,297,955 inhabitants. The results revealed that every citizen can use an AED in 15 countries whereas a training certificate was required in three countries. In one country, only EMS personnel were allowed to use an AED. An AED mapping system and FRs equipped with an AED were available in only 11 countries. The AED use rate was 12–59% where AED mapping and FR systems were implemented, which was considerably higher than in other countries (0–7.9%), reflecting the difference in OHCA survival. Conclusions: Our survey highlighted a heterogeneity in AED legislation, AED mapping systems and AED use in Europe, which was re-flected in different AED use and survival

    Regional Climates

    No full text