430 research outputs found
Floral vascular patterns of the double-flowered and wild-type morphs of Nigella damascena L. (Ranunculaceae)
The perianth of the double-flowered morph of Nigella damascena L. consists of spirally inserted petaloid sepals and sepal-like organs, similar in shape and colour to the petaloid sepals of the wild-type flower. It is devoid of petals. We compare the vascularization of each organ category of the double flower with that of the wild-type. We show that the vascular patterns of the sepal-like organs and of the petals are identical, and found an inverse relationship between the number of bracts and the number of sepals in the double-flowered morph. These two surprising findings will influence the future evo-devo studies on this plant model
Modelling of a conservative pollutant transfer in a periurban stream: comparisons and applications of several models
The STAR Silicon Strip Detector (SSD)
The STAR Silicon Strip Detector (SSD) completes the three layers of the
Silicon Vertex Tracker (SVT) to make an inner tracking system located inside
the Time Projection Chamber (TPC). This additional fourth layer provides two
dimensional hit position and energy loss measurements for charged particles,
improving the extrapolation of TPC tracks through SVT hits. To match the high
multiplicity of central Au+Au collisions at RHIC the double sided silicon strip
technology was chosen which makes the SSD a half million channels detector.
Dedicated electronics have been designed for both readout and control. Also a
novel technique of bonding, the Tape Automated Bonding (TAB), was used to
fullfill the large number of bounds to be done. All aspects of the SSD are
shortly described here and test performances of produced detection modules as
well as simulated results on hit reconstruction are given.Comment: 11 pages, 8 figures, 1 tabl
Zinc-gallium oxynitride powders: effect of the oxide precursor synthesis route
International audienceZinc-gallium oxynitride powders (ZnGaON) were synthesized by nitridation of ZnGa2O4 oxide precursor obtained by polymeric precursors (PP) and solid state reaction (SSR) methods and the influence of the synthesis route of ZnGa2O4 on the final compound ZnGaON was investigated. Crystalline single phase ZnGa2O4 was obtained at 1100 oC / 12 h by SSR and at 600 oC / 2 h by PP with different grain sizes and specific surface areas according to the synthesis route. After nitridation, ZnGaON oxynitrides with a GaN würtzite-type structure were obtained in both cases, however at lower temperatures for PP samples. The microstructure and the specific surface area were strongly dependent on the oxide synthesis method and on the nitridation temperature (42 m2g-1 and 5 m2g-1 for PP and SSR oxides treated at 700 °C, respectively). The composition analyses showed a strong loss of Zn for the PP samples, favored by the increase of ammonolysis temperature and by the higher specific surface area
Online Monitoring of the Osiris Reactor with the Nucifer Neutrino Detector
Originally designed as a new nuclear reactor monitoring device, the Nucifer
detector has successfully detected its first neutrinos. We provide the second
shortest baseline measurement of the reactor neutrino flux. The detection of
electron antineutrinos emitted in the decay chains of the fission products,
combined with reactor core simulations, provides an new tool to assess both the
thermal power and the fissile content of the whole nuclear core and could be
used by the Inter- national Agency for Atomic Energy (IAEA) to enhance the
Safeguards of civil nuclear reactors. Deployed at only 7.2m away from the
compact Osiris research reactor core (70MW) operating at the Saclay research
centre of the French Alternative Energies and Atomic Energy Commission (CEA),
the experiment also exhibits a well-suited configuration to search for a new
short baseline oscillation. We report the first results of the Nucifer
experiment, describing the performances of the 0.85m3 detector remotely
operating at a shallow depth equivalent to 12m of water and under intense
background radiation conditions. Based on 145 (106) days of data with reactor
ON (OFF), leading to the detection of an estimated 40760 electron
antineutrinos, the mean number of detected antineutrinos is 281 +- 7(stat) +-
18(syst) electron antineutrinos/day, in agreement with the prediction 277(23)
electron antineutrinos/day. Due the the large background no conclusive results
on the existence of light sterile neutrinos could be derived, however. As a
first societal application we quantify how antineutrinos could be used for the
Plutonium Management and Disposition Agreement.Comment: 22 pages, 16 figures - Version
Double-crowned 2D semiconductor nanoplatelets with bicolor power-tunable emission
Nanocrystals (NCs) are now established building blocks for optoelectronics and their use as down converters for large gamut displays has been their first mass market. NC integration relies on a combination of green and red NCs into a blend, which rises post-growth formulation issues. A careful engineering of the NCs may enable dual emissions from a single NC population which violates Kasha’s rule, which stipulates that emission should occur at the band edge. Thus, in addition to an attentive control of band alignment to obtain green and red signals, non-radiative decay paths also have to be carefully slowed down to enable emission away from the ground state. Here, we demonstrate that core/crown/crown 2D nanoplatelets (NPLs), made of CdSe/CdTe/CdSe, can combine a large volume and a type-II band alignment enabling simultaneously red and narrow green emissions. Moreover, we demonstrate that the ratio of the two emissions can be tuned by the incident power, which results in a saturation of the red emission due to non-radiative Auger recombination that affects this emission much stronger than the green one. Finally, we also show that dual-color, power tunable, emission can be obtained through an electrical excitation
Development and performance of Triple-GEM detectors for the upgrade of the muon system of the CMS experiment
The CMS Collaboration is evaluating GEM detectors for the upgrade of the muon system. This contribution will focus on the R&D performed on chambers design features and will discuss the performance of the upgraded detector
Overview of large area triple-GEM detectors for the CMS forward muon upgrade
In order to cope with the harsh environment expected from the high luminosity LHC, the CMS forward muon system requires an upgrade. The two main challenges expected in this environment are an increase in the trigger rate and increased background radiation leading to a potential degradation of the particle ID performance. Additionally, upgrades to other subdetectors of CMS allow for extended coverage for particle tracking, and adding muon system coverage to this region will further enhance the performance of CMS
A novel application of Fiber Bragg Grating (FBG) sensors in MPGD
We present a novel application of Fiber Bragg Grating (FBG) sensors in the
construction and characterisation of Micro Pattern Gaseous Detector (MPGD),
with particular attention to the realisation of the largest triple (Gas
electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the
CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of
about 0.5 m2 active area each, employing three GEM foils per chamber, to be
installed in the forward region of the CMS endcap during the long shutdown of
LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM
foils that are mechanically stretched in order to secure their flatness and the
consequent uniform performance of the GE1/1 chamber across its whole active
surface. So far FBGs have been used in high energy physics mainly as high
precision positioning and re-positioning sensors and as low cost, easy to
mount, low space consuming temperature sensors. FBGs are also commonly used for
very precise strain measurements in material studies. In this work we present a
novel use of FBGs as flatness and mechanical tensioning sensors applied to the
wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used
to determine the optimal mechanical tension applied and to characterise the
mechanical tension that should be applied to the foils. We discuss the results
of the test done on a full-sized GE1/1 final prototype, the studies done to
fully characterise the GEM material, how this information was used to define a
standard assembly procedure and possible future developments.Comment: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste,
Italy). arXiv admin note: text overlap with arXiv:1512.0848
Charged particle detection performance of Gas Electron Multiplier (GEM) detectors for the upgrade of CMS endcap muon system at the CERN LHC
The Compact Muon Solenoid (CMS) detector is one of the two general-purpose detectors at the CERN LHC. LHC will provide exceptional high instantaneous and integrated luminosity after second long shutdown. The forward region |η| ≥ 1:5 of CMS detector will face extremely high particle rates in tens of kHz/cm2 and hence it will affect the momentum resolution, efficiency and longevity of the muon detectors. Here, η is pseudorapidity defined as η = -ln(tan(θ/2)), where θ is the polar angle measured from z-axis. To overcome these issues the CMSGEM collaboration has proposed to install new large size rate capable Triple Gas Electron Multiplier (GEM) detectors in the forward region of CMS muon system. The first set of Triple GEM detectors will be installed in the GE1/1 region (1:6 <; |η| <; 2.2) of the muon endcap during the long shutdown 2 (LS2) of the LHC. Towards this goal, full size CMS Triple GEM detectors have been fabricated and tested at the CERN SPS, H2 and H4 test beam facility. The GEM detectors were operated with two gas mixtures: Ar/CO2 (70/30) and Ar/CO2/CF4 (45/15/40). In 2014, good quality data was collected during test beam campaigns. In this paper, the performance of the detectors is summarized based on their tracking efficiency and time resolution
- …