96 research outputs found

    Validity and reliability of the assessment tool for Asthma (ATA) questionnaire: the ATA study

    Get PDF
    OBJECTIVES: A multicenter trial was designed to validate the “Assessment Tools for Asthma (ATA)” questionnaire, a newly developed questionnaire, which evaluates both asthma control and risk factors associated with asthma control with a single instrument. MATERIALS AND METHODS: This cross-sectional study involved 810 cases from 14 clinics in 9 Turkish cities. The ATA questionnaire and Asthma Control Test (ACT) were administered. The Visual Analog Scale (VAS) was used to evaluate the control status of 100 randomized cases. ATA is an eight-item physician-administered questionnaire. It comprises the following two sections-ATA1, assesses symptomatic control criteria, and the remaining section, queries the flre-up of asthma, control of comorbidities, treatment adherence, and inhaler technique. RESULTS: The mean scores for ATA1, ATA total, VAS, and ACT were 24.7±14.8, 53.8±19, 7.1±3, and 18.8±5.5, respectively. According to the ATA questionnaire, among all patients, 34.3% had controlled, 18.8% had partly controlled, and 46.9% had uncontrolled asthma. Furthermore, 16.6% patients had flre-ups between visits, 96.4% patients had uncontrolled comorbidity, 17% patients had irregular asthma treatment, and only 8.4% patients used the incorrect inhaler technique. The ATA questionnaire showed internal consistency (Cronbach’s alpha coeffiient=0.683). ACT, ATA1, and two specialists’ evaluations using VAS correlated strongly with the ATA total scores (Spearman correlation coeffiient (r) values: 0.776, 0.783, and 0.909, respectively; p-values: p<0.001, p<0.001, and p<0.001, respectively). According to Receiver Operating Characteristic analysis, the cut-off value of ATA was 50 (sensitivity=84.4%, specifiity=82.40%). CONCLUSION: The validated ATA questionnaire may be a practical tool for physicians in asthma management

    Spices to Control COVID-19 Symptoms:Yes, but Not Only…

    Get PDF
    There are large country variations in COVID-19 death rates that may be partly explained by diet. Many countries with low COVID-19 death rates have a common feature of eating large quantities of fermented vegetables such as cabbage and, in some continents, various spices. Fermented vegetables and spices are agonists of the antioxidant transcription factor nuclear factor (erythroid-derived 2)-like 2 (Nrf2), and spices are transient receptor potential ankyrin 1 and vanillin 1 (TRPA1/V1) agonists. These mechanisms may explain many COVID-19 symptoms and severity. It appears that there is a synergy between Nrf2 and TRPA1/V1 foods that may explain the role of diet in COVID-19. One of the mechanisms of COVID-19 appears to be an oxygen species (ROS)-mediated process in synergy with TRP channels, modulated by Nrf2 pathways. Spicy foods are likely to desensitize TRP channels and act in synergy with exogenous antioxidants that activate the Nrf2 pathway

    Country activities of Global Alliance against Chronic Respiratory Diseases (GARD): focus presentations at the 11th GARD General Meeting, Brussels

    Get PDF
    © Journal of Thoracic Disease. All rights reserved.The Global Alliance against Chronic Respiratory Diseases (GARD) is a voluntary network of national and international organizations, institutions and agencies led by the World Health Organization (WHO), working towards the vision of a world where all people breathe freely (1). GARD is supporting WHO in successfully implementing the WHO’s Global Action Plan for the Prevention and Control of Noncommunicable Diseases (NCDs) 2013–2020. The GARD report on GARD activities is published on a regular basis. Collaboration among GARD countries is critical for sharing experiences and providing technical assistance to developing countries based on each country’s needs (2). The annual GARD meeting is a unique opportunity for assembling all of the GARD participants from developed and developing countries: European countries, North and South American Countries, China, Vietnam as well as Eastern Mediterranean, and African countries. Coordinator for Management of NCDs in the WHO Department for Management of Noncommunicable Diseases, Disability, Violence and Injury Prevention (Cherian Varghese) is present at this meeting. The annual meeting of GARD is a forum for exchanging opinions in order to improve care for chronic respiratory diseases (CRDs) and to achieve the GARD goal—a world where all people breathe freely. Experts—in collaboration with WHO—are helping developing countries to achieve their projects regarding teaching, research and programming for CRD. Each year, there is a poster presentation session on country activities. Each participant is able to present his/her country activities that have been achieved since the last meeting. This is followed by discussion. In this paper, we summarize the posters presented during the 11th GARD general meeting. We hope that this will give readers of the GARD section an opportunity to learn for their countries. We can find all posters on the link: https://gard-breathefreely.org/resources-poster/.info:eu-repo/semantics/publishedVersio

    Validity, reliability, and responsiveness of daily monitoring visual analog scales in MASK‐air®

    Get PDF
    Background: MASK-air® is an app that supports allergic rhinitis patients in disease control. Users register daily allergy symptoms and their impact on activities using visual analog scales (VASs). We aimed to assess the concurrent validity, reliability, and responsiveness of these daily VASs. Methods: Daily monitoring VAS data were assessed in MASK-air® users with allergic rhinitis. Concurrent validity was assessed by correlating daily VAS values with those of the EuroQol-5 Dimensions (EQ-5D) VAS, the Control of Allergic Rhinitis and Asthma Test (CARAT) score, and the Work Productivity and Activity Impairment Allergic Specific (WPAI-AS) Questionnaire (work and activity impairment scores). Intra-rater reliability was assessed in users providing multiple daily VASs within the same day. Test–retest reliability was tested in clinically stable users, as defined by the EQ-5D VAS, CARAT, or “VAS Work” (i.e., VAS assessing the impact of allergy on work). Responsiveness was determined in users with two consecutive measurements of EQ-5D-VAS or “VAS Work” indicating clinical change. Results: A total of 17,780 MASK-air® users, with 317,176 VAS days, were assessed. Concurrent validity was moderate–high (Spearman correlation coefficient range: 0.437–0.716). Intra-rater reliability intraclass correlation coefficients (ICCs) ranged between 0.870 (VAS assessing global allergy symptoms) and 0.937 (VAS assessing allergy symptoms on sleep). Test–retest reliability ICCs ranged between 0.604 and 0.878—“VAS Work” and “VAS asthma” presented the highest ICCs. Moderate/large responsiveness effect sizes were observed—the sleep VAS was associated with lower responsiveness, while the global allergy symptoms VAS demonstrated higher responsiveness. Conclusion: In MASK-air®, daily monitoring VASs have high intra-rater reliability and moderate–high validity, reliability, and responsiveness, pointing to a reliable measure of symptom loads

    Validity, reliability, and responsiveness of daily monitoring visual analog scales in MASK-air (R)

    Get PDF
    Background MASK-air (R) is an app that supports allergic rhinitis patients in disease control. Users register daily allergy symptoms and their impact on activities using visual analog scales (VASs). We aimed to assess the concurrent validity, reliability, and responsiveness of these daily VASs. Methods Daily monitoring VAS data were assessed in MASK-air (R) users with allergic rhinitis. Concurrent validity was assessed by correlating daily VAS values with those of the EuroQol-5 Dimensions (EQ-5D) VAS, the Control of Allergic Rhinitis and Asthma Test (CARAT) score, and the Work Productivity and Activity Impairment Allergic Specific (WPAI-AS) Questionnaire (work and activity impairment scores). Intra-rater reliability was assessed in users providing multiple daily VASs within the same day. Test-retest reliability was tested in clinically stable users, as defined by the EQ-5D VAS, CARAT, or "VAS Work" (i.e., VAS assessing the impact of allergy on work). Responsiveness was determined in users with two consecutive measurements of EQ-5D-VAS or "VAS Work" indicating clinical change. Results A total of 17,780 MASK-air (R) users, with 317,176 VAS days, were assessed. Concurrent validity was moderate-high (Spearman correlation coefficient range: 0.437-0.716). Intra-rater reliability intraclass correlation coefficients (ICCs) ranged between 0.870 (VAS assessing global allergy symptoms) and 0.937 (VAS assessing allergy symptoms on sleep). Test-retest reliability ICCs ranged between 0.604 and 0.878-"VAS Work" and "VAS asthma" presented the highest ICCs. Moderate/large responsiveness effect sizes were observed-the sleep VAS was associated with lower responsiveness, while the global allergy symptoms VAS demonstrated higher responsiveness. Conclusion In MASK-air (R), daily monitoring VASs have high intra-rater reliability and moderate-high validity, reliability, and responsiveness, pointing to a reliable measure of symptom loads.</p

    Erratum to: Scaling up strategies of the chronic respiratory disease programme of the European Innovation Partnership on Active and Healthy Ageing (Action Plan B3: Area 5)

    Get PDF

    The reference site collaborative network of the european innovation partnership on active and healthy ageing

    Get PDF
    Seventy four Reference Sites of the European Innovation Partnership on Active and Healthy Ageing (EIP on AHA) have been recognised by the European Commission in 2016 for their commitment to excellence in investing and scaling up innovative solutions for active and healthy ageing. The Reference Site Collaborative Network (RSCN) brings together the EIP on AHA Reference Sites awarded by the European Commission, and Candidate Reference Sites into a single forum. The overarching goals are to promote cooperation, share and transfer good practice and solutions in the development and scaling up of health and care strategies, policies and service delivery models, while at the same time supporting the action groups in their work. The RSCN aspires to be recognized by the EU Commission as the principal forum and authority representing all EIP on AHA Reference Sites. The RSCN will contribute to achieve the goals of the EIP on AHA by improving health and care outcomes for citizens across Europe, and the development of sustainable economic growth and the creation of jobs

    ARIA digital anamorphosis: Digital transformation of health and care in airway diseases from research to practice

    Get PDF
    Digital anamorphosis is used to define a distorted image of health and care that may be viewed correctly using digital tools and strategies. MASK digital anamorphosis represents the process used by MASK to develop the digital transformation of health and care in rhinitis. It strengthens the ARIA change management strategy in the prevention and management of airway disease. The MASK strategy is based on validated digital tools. Using the MASK digital tool and the CARAT online enhanced clinical framework, solutions for practical steps of digital enhancement of care are proposed
    corecore