62 research outputs found

    Can remifentanil use in obstetrics be improved by optimal patient-controlled analgesia bolus timing?

    Get PDF
    Background The safety of patient-controlled i.v. analgesia (PCA) with remifentanil for obstetrical analgesia remains a matter of concern. The efficacy of remifentanil bolus application, that is, the coincidence between pain and remifentanil effect-site concentration, may be improved by forecasting contractions, but it is not known whether such a technique would also improve safety. Methods We recorded pain intensity during labour continuously using a handheld dynamometer in 43 parturients. Using these data, we compared different models in their ability to predict future contractions. In addition, we modelled remifentanil effect-site concentration using three simulated modes of bolus administration, with and without prediction of future contractions. Results The average duration of pain during contractions recorded by the dynamometer was 45 [14 standard deviation (sd)] s. The time interval between painful contractions was highly variable, with a mean of 151 (31 sd) s during the first and 154 (52 sd) s during the second recording. Using a simple algorithm (three-point moving average), the sd of the difference between predicted and observed inter-contraction intervals can be reduced from 0.95 to 0.79 min. However, the coincidence between remifentanil concentration and pain during contraction is not substantially improved when using these models to guide remifentanil bolus application. Conclusions Because of the large variability of inter-contraction intervals, the use of prediction models will not influence the mean remifentanil concentration in-between contractions. Using models predicting future contractions to improve the timing of remifentanil PCA bolus administration will not diminish the need of continuous clinical surveillance and other safety measure

    Innovations to Improve Lung Isolation Training for Thoracic Anesthesia: A Narrative Review.

    Get PDF
    A double-lumen tube or bronchial blocker positioning using flexible bronchoscopy for lung isolation and one-lung ventilation requires specific technical competencies. Training to acquire and retain such skills remains a challenge in thoracic anesthesia. Recent technological and innovative developments in the field of simulation have opened up exciting new horizons and possibilities. In this narrative review, we examine the latest development of existing training modalities while investigating, in particular, the use of emergent techniques such as virtual reality bronchoscopy simulation, virtual airway endoscopy, or the preoperative 3D printing of airways. The goal of this article is, therefore, to summarize the role of existing and future applications of training models/simulators and virtual reality simulators for training flexible bronchoscopy and lung isolation for thoracic anesthesia

    Multimodal Highlighting of Structural Abnormalities in Diabetic Rat and Human Corneas.

    Get PDF
    PURPOSE: This study aimed to highlight structural corneal changes in a model of type 2 diabetes, using in vivo corneal confocal microscopy (CCM). The abnormalities were also characterized by transmission electron microscopy (TEM) and second harmonic generation (SHG) microscopy in rat and human corneas. METHODS: Goto-Kakizaki (GK) rats were observed at age 12 weeks (n = 3) and 1 year (n = 6), and compared to age-matched controls. After in vivo CCM examination, TEM and SHG microscopy were used to characterize the ultrastructure and the three-dimensional organization of the abnormalities. Human corneas from diabetic (n = 3) and nondiabetic (n = 3) patients were also included in the study. RESULTS: In the basal epithelium of GK rats, CCM revealed focal hyper-reflective areas, and histology showed proliferative cells with irregular basement membrane. In the anterior stroma, extracellular matrix modifications were detected by CCM and confirmed in histology. In the Descemet's membrane periphery of all the diabetic corneas, hyper-reflective deposits were highlighted using CCM and characterized as long-spacing collagen fibrils by TEM. SHG microscopy revealed these deposits with high contrast, allowing specific detection in diabetic human and rat corneas without preparation and characterization of their three-dimensional organization. CONCLUSION: Pathologic findings were observed early in the development of diabetes in GK rats. Similar abnormalities have been found in corneas from diabetic patients. TRANSLATIONAL RELEVANCE: This multidisciplinary study highlights diabetes-induced corneal abnormalities in an animal model, but also in diabetic donors. This could constitute a potential early marker for diagnosis of hyperglycemia-induced tissue changes

    Total gas and methane emissions of black soldier fly Hermetia illucens grown on different organic wastes

    Get PDF
    Edible insects have been suggested as an alternative source of protein for animal feeding. The production of insect meals should have a lower environmental impact as compared to other productions such as beef or dairy products. However, few information is available in literature with special regards to Green House gases emissions. An experiment was conducted to quantify emission of gas and methane by larvae of the black soldier fly (BSF) Hermetia illucens (Diptera Stratiomyidae) grown on different organic wastes. The experimental substrates were: a standard hen diet (control), okara, maize grain dry distillers and brewers spent grain mixed with trub (derived from brewing process). An in vitro method derived by evaluation of feed for ruminants using a semiautomatic pressure system was adapted for this purpose. Twenty BSF larvae were positioned in duplicate into serum bottles and added with the experimental substrates (diets) ad libitum. For each sample two blanks (i.e. substrates without larvae) were added. Headspace pressure was recorded after 24 hours of incubation using a digital manometer (model 840082, Sper Scientific, Scottsdale, AZ, USA). The gas pressure data were converted to moles of gas using the ideal gas law. A fixed-volume sample of gas was also collected for subsequent methane analysis using gas-tight syringes fitted with needles through the bottle top. The gas composition of the headspace was determined by micro GC gas chromatograph (Agilent Technologies, Santa Clara, CA, USA). An external standard mixture of CO2 and CH4 was used for instrument calibration. For all substrates, no detectable traces of methane were determined in the analysed air samples. There were differences on total gas (ml of Gas/g of incubated dry matter) produced by BSF larvae incubated with the different substrates and corrected for the blank gas production. Particularly, total gas productions were higher for larvae incubated with hen diet and brewers mixed with trub, intermediate for okara and lower for larvae incubated with distiller grains. The method proposed seems promising to estimate gas and CH4 productions of BSF larvae in a simply and fast way. The differences in gas production between BSF larvae fed with the different substrates could be useful to better define the optimal diets for this specie

    The outer limiting membrane (OLM) revisited: clinical implications

    Get PDF
    PURPOSE: The outer limiting membrane (OLM) is considered to play a role in maintaining the structure of the retina through mechanical strength. However, the observation of junction proteins located at the OLM and its barrier permeability properties may suggest that the OLM may be part of the retinal barrier. MATERIAL AND METHODS: Normal and diabetic rat, monkey, and human retinas were used to analyze junction proteins at the OLM. Proteome analyses were performed using immunohistochemistry on sections and flat-mounted retinas and western blotting on protein extracts obtained from laser microdissection of the photoreceptor layers. Semi-thin and ultrastructure analyses were also reported. RESULTS: In the rat retina, in the subapical region zonula occludens-1 (ZO-1), junction adhesion molecule (JAM), an atypical protein kinase C, is present and the OLM shows dense labeling of occludin, JAM, and ZO-1. The presence of occludin has been confirmed using western blot analysis of the microdissected OLM region. In diabetic rats, occludin expression is decreased and glial cells junctions are dissociated. In the monkey retina, occludin, JAM, and ZO-1 are also found in the OLM. Junction proteins have a specific distribution around cone photoreceptors and Müller glia. Ultrastructural analyses suggest that structures like tight junctions may exist between retinal glial Müller cells and photoreceptors. CONCLUSIONS: In the OLM, heterotypic junctions contain proteins from both adherent and tight junctions. Their structure suggests that tight junctions may exist in the OLM. Occludin is present in the OLM of the rat and monkey retina and it is decreased in diabetes. The OLM should be considered as part of the retinal barrier that can be disrupted in pathological conditions contributing to fluid accumulation in the macula

    Injury and Illness Rates During Ultratrail Running

    Get PDF
    This study aimed to describe injury/illness rates in ultratrail runners competing in a 65-km race to build a foundation for injury prevention and help race organizers to plan medical provision for these events. Prospectively transcribed medical records were analysed for 77 athletes at the end of the race. Number of injuries/illnesses per 1\u2009000 runners and per 1\u2009000-h run, overall injury/illness rate and 90% confidence intervals and rates for major and minor illnesses, musculoskeletal injuries, and skin disorders were analysed. A total of 132 injuries/illnesses were encountered during the race. The overall injuries/illnesses were 1.9 per runner and 13.1 per 1\u2009000-h run. Medical illnesses were the most prominent medical diagnoses encountered (50.3%), followed by musculoskeletal injuries (32.8%), and skin-related disorders (16.9%). Despite the ultra-long nature of the race, the majority of injuries/illnesses were minor in nature. Medical staff and runners should prepare to treat all types of injuries and illnesses, especially the fatigue arising throughout the course of an ultratrail run and injuries to the lower limbs. Future studies should attempt to systematically identify injury locations and mechanisms in order to better direct injury prevention strategies and plan more accurate medical care

    The use of the Airtraq® optical laryngoscope for routine tracheal intubation in high-risk cardio-surgical patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Airtraq<sup>® </sup>optical laryngoscope (Prodol Ltd., Vizcaya, Spain) is a novel disposable device facilitating tracheal intubation in routine and difficult airway patients. No data investigating routine tracheal intubation using the Airtaq<sup>® </sup>in patients at a high cardiac risk are available at present. Purpose of this study was to investigate the feasibility and hemodynamic implications of tracheal intubation with the Aitraq<sup>® </sup>optical laryngoscope, in high-risk cardio-surgical patients.</p> <p>Methods</p> <p>123 consecutive ASA III patients undergoing elective coronary artery bypass grafting were routinely intubated with the Airtraq<sup>® </sup>laryngoscope. Induction of anesthesia was standardized according to our institutional protocol. All tracheal intubations were performed by six anesthetists trained in the use of the Airtraq<sup>® </sup>prior.</p> <p>Results</p> <p>Overall success rate was 100% (n = 123). All but five patients trachea could be intubated in the first attempt (95,9%). 5 patients were intubated in a 2nd (n = 4) or 3rd (n = 1) attempt. Mean intubation time was 24.3 s (range 16-128 s). Heart rate, arterial blood pressure and SpO<sub>2 </sub>were not significantly altered. Minor complications were observed in 6 patients (4,8%), i.e. two lesions of the lips and four minor superficial mucosal bleedings. Intubation duration (p = 0.62) and number of attempts (p = 0.26) were independent from BMI and Mallampati score.</p> <p>Conclusion</p> <p>Tracheal intubation with the Airtraq<sup>® </sup>optical laryngoscope was feasible, save and easy to perform in high-risk patients undergoing cardiac surgery. In all patients, a sufficient view on the vocal cords could be obtained, independent from BMI and preoperative Mallampati score.</p> <p>Trial Registration</p> <p>DRKS 00003230</p

    Patient Safety in the Cardiac Operating Room: Human Factors and Teamwork: A Scientific Study from the American Heart Association

    Get PDF
    The cardiac surgical operating room (OR) is a complex environment in which highly trained subspecialists interact with each other using sophisticated equipment to care for patients with severe cardiac disease and significant comorbidities. Thousands of patient lives have been saved or significantly improved with the advent of modern cardiac surgery. Indeed, both mortality and morbidity for coronary artery bypass surgery have decreased during the past decade. Nonetheless, the highly skilled and dedicated personnel in cardiac ORs are human and will make errors. Refined techniques, advanced technologies, and enhanced coordination of care have led to significant improvements in cardiac surgery outcomes
    corecore