14 research outputs found

    Impact of operatoŕs experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry

    Get PDF
    Background: The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX. Methods: Prospective, multicenter, 'real-world' registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center's prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed ≤ 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared. Results: 359 patients [mean age 75.5 (SD8.1), CHA2DS2-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9)] were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the centeŕs previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed. Conclusions: The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operatoŕs experience with its previous device iteration or the number of Watchman FLX devices implanted

    Accuracy of Xpert Ultra for the diagnosis of paediatric tuberculosis in a low TB burden country: a prospective multicentre study

    Get PDF
    [Introduction] Childhood pulmonary tuberculosis (TB) remains a diagnostic challenge. This study aimed to evaluate the performance of Xpert Ultra for the diagnosis of pulmonary TB in children in a low TB prevalence setting.[Methods] Prospective, multicentre, diagnostic accuracy study. Children with clinical or radiological suspicion of pulmonary TB were recruited at 11 paediatric units in Spain. Up to three gastric or sputum specimens were taken on 3 consecutive days, and analysed by Xpert MTB/RIF, Xpert Ultra and culture in parallel.[Results] 86 children were included (median age 4.9 years, IQR 2.0–10.0; 51.2% male). The final diagnosis was pulmonary TB in 75 patients (87.2%); 33 (44.0%) were microbiologically confirmed. A total of 219 specimens, comprising gastric aspirates (n=194; 88.6%) and sputum specimens (n=25; 11.4%), were analysed. Using culture as reference standard and comparing individual specimens, the sensitivity was 37.8% (14/37) for Xpert MTB/RIF and 81.1% (30/37) for Xpert Ultra (p<0.001); specificity was 98.4% (179/182) and 93.4% (170/182), respectively (p=0.02). In the per-patient analysis, considering positive results on any specimen, the sensitivity was 42.9% (9/21) for Xpert MTB/RIF and 81.0% for Xpert Ultra (17/21, p=0.01); specificity was 96.9% (63/65) and 87.7% (57/65, p=0.07), respectively.[Conclusions] In children with pulmonary TB in a low burden setting, Xpert Ultra has significantly higher sensitivity than the previous generation of Xpert assay and only marginally lower specificity. Therefore, in children undergoing evaluation for suspected pulmonary TB, Xpert Ultra should be used in preference to Xpert MTB/RIF whenever possible.This study did not receive any project-specific funding. DA-A was supported by the Spanish Ministry of Health – Instituto de Salud Carlos III (ISCIII) and cofunded by the European Union (FEDER) (Contrato Río Hortega CM18/00100). AN-J was supported by 'Subvencions per a la Intensificació de Facultatius Especialistes' (Departament de Salut de la Generalitat de Catalunya, Programa PERIS 2016-2020) (SLT008/18/00193). DBG was supported by the Spanish Ministry of Science and Innovation – Instituto de Salud Carlos III and Fondos FEDER by 'Contratos para la intensificación de la actividad investigadora en el Sistema Nacional de Salud, 2020 (INT20/00086)'. BS-G was supported by the Spanish Ministry of Health – Instituto de Salud Carlos III (ISCIII) and cofunded by the European Union (FEDER) (Contrato Juan Rodés JR16/00036).Peer reviewe

    Role of age and comorbidities in mortality of patients with infective endocarditis

    Get PDF
    [Purpose]: The aim of this study was to analyse the characteristics of patients with IE in three groups of age and to assess the ability of age and the Charlson Comorbidity Index (CCI) to predict mortality. [Methods]: Prospective cohort study of all patients with IE included in the GAMES Spanish database between 2008 and 2015.Patients were stratified into three age groups:<65 years,65 to 80 years,and ≥ 80 years.The area under the receiver-operating characteristic (AUROC) curve was calculated to quantify the diagnostic accuracy of the CCI to predict mortality risk. [Results]: A total of 3120 patients with IE (1327 < 65 years;1291 65-80 years;502 ≥ 80 years) were enrolled.Fever and heart failure were the most common presentations of IE, with no differences among age groups.Patients ≥80 years who underwent surgery were significantly lower compared with other age groups (14.3%,65 years; 20.5%,65-79 years; 31.3%,≥80 years). In-hospital mortality was lower in the <65-year group (20.3%,<65 years;30.1%,65-79 years;34.7%,≥80 years;p < 0.001) as well as 1-year mortality (3.2%, <65 years; 5.5%, 65-80 years;7.6%,≥80 years; p = 0.003).Independent predictors of mortality were age ≥ 80 years (hazard ratio [HR]:2.78;95% confidence interval [CI]:2.32–3.34), CCI ≥ 3 (HR:1.62; 95% CI:1.39–1.88),and non-performed surgery (HR:1.64;95% CI:11.16–1.58).When the three age groups were compared,the AUROC curve for CCI was significantly larger for patients aged <65 years(p < 0.001) for both in-hospital and 1-year mortality. [Conclusion]: There were no differences in the clinical presentation of IE between the groups. Age ≥ 80 years, high comorbidity (measured by CCI),and non-performance of surgery were independent predictors of mortality in patients with IE.CCI could help to identify those patients with IE and surgical indication who present a lower risk of in-hospital and 1-year mortality after surgery, especially in the <65-year group

    Outpatient Parenteral Antibiotic Treatment vs Hospitalization for Infective Endocarditis: Validation of the OPAT-GAMES Criteria

    Get PDF

    Abbreviated or Standard Antiplatelet Therapy in HBR Patients: Final 15-Month Results of the MASTER-DAPT Trial.

    No full text
    BACKGROUND Clinical outcomes and treatment selection after completing the randomized phase of modern trials, investigating antiplatelet therapy (APT) after percutaneous coronary intervention (PCI), are unknown. OBJECTIVES The authors sought to investigate cumulative 15-month and 12-to-15-month outcomes after PCI during routine care in the MASTER DAPT trial. METHODS The MASTER DAPT trial randomized 4,579 high bleeding risk patients to abbreviated (n = 2,295) or standard (n = 2,284) APT regimens. Coprimary outcomes were net adverse clinical outcomes (NACE) (all-cause death, myocardial infarction, stroke, and BARC 3 or 5 bleeding); major adverse cardiac and cerebral events (MACCE) (all-cause death, myocardial infarction, and stroke); and BARC type 2, 3, or 5 bleeding. RESULTS At 15 months, prior allocation to a standard APT regimen was associated with greater use of intensified APT; NACE and MACCE did not differ between abbreviated vs standard APT (HR: 0.92 [95% CI: 0.76-1.12]; P = 0.399 and HR: 0.94 [95% CI: 0.76-1.17]; P = 0.579; respectively), as during the routine care period (HR: 0.81 [95% CI: 0.50-1.30]; P = 0.387 and HR: 0.74 [95% CI: 0.43-1.26]; P = 0.268; respectively). BARC 2, 3, or 5 was lower with abbreviated APT at 15 months (HR: 0.68 [95% CI: 0.56-0.83]; P = 0.0001) and did not differ during the routine care period. The treatment effects during routine care were consistent with those observed within 12 months after PCI. CONCLUSIONS At 15 months, NACE and MACCE did not differ in the 2 study groups, whereas the risk of major or clinically relevant nonmajor bleeding remained lower with abbreviated compared with standard APT. (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With an Abbreviated Versus Prolonged DAPT Regimen [MASTER DAPT]; NCT03023020)

    Impact of operator's experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry

    No full text
    Background The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX. Methods Prospective, multicenter, ?real-world? registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center?s prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed ? 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared. Results 359 patients [mean age 75.5 (SD8.1), CHA2DS2-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9)] were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the cente?s previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed. Conclusions The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operato?s experience with its previous device iteration or the number of Watchman FLX devices implanted.Acknowledgments: We would like to express our gratitude to Jose Santaursula Pastor for the production of the figures in this work
    corecore