88 research outputs found
Waveguide Bandpass Filters for Millimeter-Wave Radiometers
A fundamental requirement for most mm-wave heterodyne receivers is the rejection of the input image signal which is located close to the local oscillator frequency. For this purpose we use a bandpass filter, which for heterodyne receivers is also called an image rejection filter. In this paper we present a systematic approach to the design of a waveguide bandpass filter with a passband from 100 to 110 GHz and upper rejection bandwidth in the range from 113 to 145 GHz. We consider two non-tunable filter configurations: the first one is relatively selective with 11 sections (poles) whereas the second one is simpler with 5 sections. We used established design equations to propose an initial guess for the geometries of the filters, optimized the geometries, constructed the filters using two different milling methods, measured their transmission and reflection characteristics, and compared the measurements with numerical simulations. Measurements of both filters agree well with simulations in frequency response and rejection bandwidth. The insertion loss of the 11-pole filter is better than 10 dB and that of the 5-pole filter is better than 5 dB. The 11-pole filter has a sharper attenuation roll-off compared with the 5-pole filter. The upper out-of-band rejection is better than 40 dB up to 145 GHz for the 11-pole filter and up to 155 GHz for the 5-pole filter
Vapor Deposited Cr-doped ZnS Thin Films: Towards Optically Pumped Mid-Infrared Waveguide Lasers
Compact, affordable mid-IR lasers require the development of gain materials in waveguide form. We report on the high vacuum deposition of Cr:ZnS films with concentration ranging from 1018-1020 dopants/cm3 . At low concentrations, films display well-isolated absorption associated with substitutional Cr2+ ions in the lattice. Spatial modulation of the dopant concentration suppresses the absorption associated with this substitution. Lateral crystallite sizes less than 30 nm are associated with the lowest substrate temperatures (\u3c50 °C) used during deposition, and waveguide losses as low as 8dB/cm are observed. These materials are promising candidates as gain media for fabrication of waveguide mid-IR lasers
Assessment of the reliability of the motor unit size index (MUSIX) in single subject âround-robinâ and multi-centre settings
Objective
The motor unit size index (MUSIX) is incorporated into the motor unit number index (MUNIX). Our objective was to assess the intra-/inter-rater reliability of MUSIX in healthy volunteers across single subject âround robinâ and multi-centre settings.
Methods
Data were obtained from i). a round-robin assessment in which 12 raters (6 with prior experience and 6 without) assessed six muscles (abductor pollicis brevis, abductor digiti minimi, biceps brachii, tibialis anterior, extensor digitorum brevis and abductor hallucis) and ii). a multi-centre study with 6 centres studying the same muscles in 66 healthy volunteers. Intra/inter-rater data were provided by 5 centres, 1 centre provided only intra-rater data.
Intra/inter-rater variability was assessed using the coefficient of variation (COV), Bland-Altman plots, bias and 95% limits of agreement.
Results
In the round-robin assessment intra-rater COVs for MUSIX ranged from 7.8% to 28.4%. Inter-rater variability was between 7.8% and 16.2%. Prior experience did not impact on MUSIX values. In the multi-centre study MUSIX was more consistent than the MUNIX. Abductor hallucis was the least reliable muscle.
Conclusions
The MUSIX is a reliable neurophysiological biomarker of reinnervation.
Significance
MUSIX could provide insights into the pathophysiology of a range of neuromuscular disorders, providing a quantitative biomarker of reinnervation
Quality Control of Motor Unit Number Index (MUNIX) Measurements in 6 Muscles in a Single-Subject âRound-Robinâ Setup
Background
Motor Unit Number Index (MUNIX) is a neurophysiological measure that provides an index
of the number of lower motor neurons in a muscle. Its performance across centres in healthy
subjects and patients with Amyotrophic Lateral Sclerosis (ALS) has been established, but
inter-rater variability between multiple raters in one single subject has not been
investigated.
Objective
To assess reliability in a set of 6 muscles in a single subject among 12 examiners (6 experienced
with MUNIX, 6 less experienced) and to determine variables associated with variability
of measurements.
Methods
Twelve raters applied MUNIX in six different muscles (abductor pollicis brevis (APB),
abductor digiti minimi (ADM), biceps brachii (BB), tibialis anterior (TA), extensor dig. brevis
(EDB), abductor hallucis (AH)) twice in one single volunteer on consecutive days. All raters
visited at least one training course prior to measurements. Intra- and inter-rater variability as
determined by the coefficient of variation (COV) between different raters and their levels of
experience with MUNIX were compared.
Results
Mean intra-rater COV of MUNIX was 14.0% (±6.4) ranging from 5.8 (APB) to 30.3% (EDB).
Mean inter-rater COV was 18.1 (±5.4) ranging from 8.0 (BB) to 31.7 (AH). No significant differences
of variability between experienced and less experienced raters were detected.
Conclusion
We provide evidence that quality control for neurophysiological methods can be performed
with similar standards as in laboratory medicine. Intra- and inter-rater variability of MUNIX is
muscle-dependent and mainly below 20%. Experienced neurophysiologists can easily
adopt MUNIX and adequate teaching ensures reliable utilization of this method
Combination of fast-ion diagnostics in velocity-space tomographies:Paper
Fast-ion Dα (FIDA) and collective Thomson scattering (CTS) diagnostics provide indirect measurements of fastion velocity distribution functions in magnetically confined plasmas. Here we present the first prescription for
velocity-space tomographic inversion of CTS and FIDA measurements that can use CTS and FIDA measurements
together and that takes uncertainties in such measurements into account. Our prescription is general and could
be applied to other diagnostics. We demonstrate tomographic reconstructions of an ASDEX Upgrade beam ion
velocity distribution function. First, we compute synthetic measurements from two CTS views and two FIDA
views using a TRANSP/NUBEAM simulation, and then we compute joint tomographic inversions in velocity-space from these. The overall shape of the 2D velocity distribution function and the location of the maxima at full and half beam injection energy are well reproduced in velocity-space tomographic inversions, if the noise level in the measurements is below 10%. Our results suggest that 2D fast-ion velocity distribution functions can be directly inferred from fast-ion measurements and their uncertainties, even if the measurements are taken with different diagnostic methods
Age-dependent motor unit remodelling in human limb muscles.
Voluntary control of skeletal muscle enables humans to interact with and manipulate the environment. Lower muscle mass, weakness and poor coordination are common complaints in older age and reduce physical capabilities. Attention has focused on ways of maintaining muscle size and strength by exercise, diet or hormone replacement. Without appropriate neural innervation, however, muscle cannot function. Emerging evidence points to a neural basis of muscle loss. Motor unit number estimates indicate that by age around 71 years, healthy older people have around 40Â % fewer motor units. The surviving low- and moderate-threshold motor units recruited for moderate intensity contractions are enlarged by around 50Â % and show increased fibre density, presumably due to collateral reinnervation of denervated fibres. Motor unit potentials show increased complexity and the stability of neuromuscular junction transmissions is decreased. The available evidence is limited by a lack of longitudinal studies, relatively small sample sizes, a tendency to examine the small peripheral muscles and relatively few investigations into the consequences of motor unit remodelling for muscle size and control of movements in older age. Loss of motor neurons and remodelling of surviving motor units constitutes the major change in ageing muscles and probably contributes to muscle loss and functional impairments. The deterioration and remodelling of motor units likely imposes constraints on the way in which the central nervous system controls movements
- âŠ