29 research outputs found

    Determination of Sugar Level and the Existence of Magic Sugar in Various Beverages using a Glucose Meter with Four-Point Probe and Electrochemical Impedance

    Get PDF
    Nowadays, people are being inconsiderate about the healthy lifestyle that might lead us to be unhealthy and be prone to developing tumors in the kidney due to some kind of sugar being used. In order to minimize these problems, the team will raise people awareness. Raising people awareness is not the same as telling them what to do. It is about giving them the knowledge to let them decide for themselves. This is why the team developed a device that can measure the sugar level and determine the existence of magic sugar in various beverages. The device is composed of two major parts: first is the circuit that will measure the impedance of a liquid sample and second, is a four-point probe, which includes a microcontroller that will display and interpret the results. The Four-point probe applies the concept of Wenner method and Electrochemical Impedance. After constructing the device, the team performed its calibration that requires different liquid samples. Based on its gathered data, different graphical representations were formulated and translated into mathematical equations in order to integrate it onto the microcontroller. Whenever the microcontroller encounters an unknown solution, it can determine the sugar level and classify the type of sugar being used

    The SuperCam Remote Sensing Instrument Suite for Mars 2020

    No full text
    International audienceThe Mars 2020 rover, essentially a structural twin of MSL, is being built to a) characterize the geology and history of a new landing site on Mars, b) find and characterize ancient habitable environments, c) cache samples for eventual return to Earth, and d) demonstrate in-situ production of oxygen needed for human exploration. Remote-sensing instrumentation is needed to support the first three of these goals [1]. The SuperCam instrument meets these needs with a range of instrumentation including the highest-resolution remote imaging on the rover, two different techniques for determining mineralogy , and one technique to provide elemental compositions. All of these techniques are co-boresighted, providing rapid comprehensive characterization. In addition, for targets within 7 meters of the rover the laser shock waves brush away the dust, providing cleaner surfaces for analysis. SuperCam will use an advanced version of the AEGIS robotic target selection software

    A global experiment on motivating social distancing during the COVID-19 pandemic

    Get PDF
    Finding communication strategies that effectively motivate social distancing continues to be a global public health priority during the COVID-19 pandemic. This cross-country, preregistered experiment (n = 25,718 from 89 countries) tested hypotheses concerning generalizable positive and negative outcomes of social distancing messages that promoted personal agency and reflective choices (i.e., an autonomy-supportive message) or were restrictive and shaming (i.e., a controlling message) compared with no message at all. Results partially supported experimental hypotheses in that the controlling message increased controlled motivation (a poorly internalized form of motivation relying on shame, guilt, and fear of social consequences) relative to no message. On the other hand, the autonomy-supportive message lowered feelings of defiance compared with the controlling message, but the controlling message did not differ from receiving no message at all. Unexpectedly, messages did not influence autonomous motivation (a highly internalized form of motivation relying on one’s core values) or behavioral intentions. Results supported hypothesized associations between people’s existing autonomous and controlled motivations and self-reported behavioral intentions to engage in social distancing. Controlled motivation was associated with more defiance and less long-term behavioral intention to engage in social distancing, whereas autonomous motivation was associated with less defiance and more short- and long-term intentions to social distance. Overall, this work highlights the potential harm of using shaming and pressuring language in public health communication, with implications for the current and future global health challenges

    Design and baseline characteristics of the finerenone in reducing cardiovascular mortality and morbidity in diabetic kidney disease trial

    Get PDF
    Background: Among people with diabetes, those with kidney disease have exceptionally high rates of cardiovascular (CV) morbidity and mortality and progression of their underlying kidney disease. Finerenone is a novel, nonsteroidal, selective mineralocorticoid receptor antagonist that has shown to reduce albuminuria in type 2 diabetes (T2D) patients with chronic kidney disease (CKD) while revealing only a low risk of hyperkalemia. However, the effect of finerenone on CV and renal outcomes has not yet been investigated in long-term trials. Patients and Methods: The Finerenone in Reducing CV Mortality and Morbidity in Diabetic Kidney Disease (FIGARO-DKD) trial aims to assess the efficacy and safety of finerenone compared to placebo at reducing clinically important CV and renal outcomes in T2D patients with CKD. FIGARO-DKD is a randomized, double-blind, placebo-controlled, parallel-group, event-driven trial running in 47 countries with an expected duration of approximately 6 years. FIGARO-DKD randomized 7,437 patients with an estimated glomerular filtration rate >= 25 mL/min/1.73 m(2) and albuminuria (urinary albumin-to-creatinine ratio >= 30 to <= 5,000 mg/g). The study has at least 90% power to detect a 20% reduction in the risk of the primary outcome (overall two-sided significance level alpha = 0.05), the composite of time to first occurrence of CV death, nonfatal myocardial infarction, nonfatal stroke, or hospitalization for heart failure. Conclusions: FIGARO-DKD will determine whether an optimally treated cohort of T2D patients with CKD at high risk of CV and renal events will experience cardiorenal benefits with the addition of finerenone to their treatment regimen. Trial Registration: EudraCT number: 2015-000950-39; ClinicalTrials.gov identifier: NCT02545049

    Nocturnal Continuous Glucose and Sleep Stage Data in Adults with Type 1 Diabetes in Real-World Conditions

    No full text
    BackgroundSleep plays an important role in health, and poor sleep is associated with negative impacts on diabetes management, but few studies have objectively evaluated sleep in adults with type 1 diabetes mellitus (T1DM). Nocturnal glycemia and sleep characteristics in T1DM were evaluated using body-worn sensors in real-world conditions.MethodsAnalyses were performed on data collected by the Diabetes Management Integrated Technology Research Initiative pilot study of 17 T1DM subjects: 10 male, 7 female; age 19-61 years; T1DM duration 14.9 ± 11.0 years; hemoglobin A1c (HbA1c) 7.3% ± 1.3% (mean ± standard deviation). Each subject was equipped with a continuous glucose monitor and a wireless sleep monitor (WSM) for four nights. Sleep stages [rapid eye movement (REM), light, and deep sleep] were continuously recorded by the WSM. Nocturnal glycemia (mg/dl) was evaluated as hypoglycemia (&lt;50 mg/dl), low (50-69 mg/dl), euglycemia (70-120 mg/dl), high (121-250 mg/dl), and hyperglycemia (&gt;250 mg/dl) and by several indices of glycemic variability. Glycemia was analyzed within each sleep stage.ResultsSubjects slept 358 ± 48 min per night, with 85 ± 27 min in REM sleep, 207 ± 42 min in light sleep, and 66 ± 30 min in deep sleep (mean ± standard deviation). Increased time in deep sleep was associated with lower HbA1c (R2 = 0.42; F = 9.37; p &lt; .01). Nocturnal glycemia varied widely between and within subjects. Glycemia during REM sleep was hypoglycemia 5.5% ± 18.1%, low 6.6% ± 18.5%, euglycemia 44.6% ± 39.5%, high 37.9% ± 39.7%, and hyperglycemia 5.5% ± 21.2%; glycemia during light sleep was hypoglycemia 4.8% ± 12.4%, low 7.3% ± 12.9%, euglycemia 42.1% ± 33.7%, high 39.2% ± 34.6%, and hyperglycemia 6.5% ± 20.5%; and glycemia during deep sleep was hypoglycemia 0.5% ± 2.2%, low 5.8% ± 14.3%, euglycemia 48.0% ± 37.5%, high 39.5% ± 37.6%, and hyperglycemia 6.2% ± 19.5%. Significantly less time was spent in the hypoglycemic range during deep sleep compared with light sleep (p = .02).ConclusionsIncreased time in deep sleep was associated with lower HbA1c, and less hypoglycemia occurred in deep sleep in T1DM, though this must be further evaluated in larger subsequent studies. Furthermore, the consumer-grade WSM device was useful for objectively studying sleep in a real-world setting

    PF-06463922, an ALK/ROS1 Inhibitor, Overcomes Resistance to First and Second Generation ALK Inhibitors in Preclinical Models

    Get PDF
    SummaryWe report the preclinical evaluation of PF-06463922, a potent and brain-penetrant ALK/ROS1 inhibitor. Compared with other clinically available ALK inhibitors, PF-06463922 displayed superior potency against all known clinically acquired ALK mutations, including the highly resistant G1202R mutant. Furthermore, PF-06463922 treatment led to regression of EML4-ALK-driven brain metastases, leading to prolonged mouse survival, in a superior manner. Finally, PF-06463922 demonstrated high selectivity and safety margins in a variety of preclinical studies. These results suggest that PF-06463922 will be highly effective for the treatment of patients with ALK-driven lung cancers, including those who relapsed on clinically available ALK inhibitors because of secondary ALK kinase domain mutations and/or brain metastases

    Impact of the permanent ventricular pacing site on left ventricular function in children: A retrospective multicentre survey

    No full text
    Background: Chronic right ventricular (RV) pacing is associated with deleterious effects on cardiac function. Objective In an observational multicentre study in children with isolated atrioventricular (AV) block receiving chronic ventricular pacing, the importance of the ventricular pacing site on left ventricular (LV) function was investigated. Methods: Demographics, maternal autoantibody status and echocardiographic measurements on LV end-diastolic and end-systolic dimensions and volumes at age 1 year) for isolated AV block. LV fractional shortening (LVFS) and, if possible LV ejection fraction (LVEF) were calculated. Linear regression analyses were adjusted for patient characteristics. Results: From 27 centres, 297 children were included, in whom pacing was applied at the RV epicardium (RVepi, n=147), RV endocardium (RVendo, n=113) or LV epicardium (LVepi, n=37). LVFS was significantly affected by pacing site (p=0.001), and not by maternal autoantibody status (p=0.266). LVFS in LVepi (39±5%) was significantly higher than in RVendo (33±7%, p<0.001) and RVepi (35±8%, p=0.001; no significant difference between RV-paced groups, p=0.275). Subnormal LVFS (LVFS<28%) was seen in 16/113 (14%) RVendo-paced and 21/147 (14%) RVepi-paced children, while LVFS was normal (LVFS≥28%) in all LVepi-paced children (p=0.049). These results are supported by the findings for LVEF (n=122): LVEF was <50% in 17/69 (25%) RVendo- and in 10/35 (29%) RVepi-paced patients, while LVEF was ≥50% in 17/18 (94%) LVepi-paced patients. Conclusion: In children with isolated AV block, permanent ventricular pacing site is an important determinant of LV function, with LVFS being significantly higher with LV pacing than with RV pacing

    The SuperCam Remote Sensing Instrument Suite for Mars 2020

    Get PDF
    The Mars 2020 rover, essentially a structural twin of MSL, is being built to a) characterize the geology and history of a new landing site on Mars, b) find and characterize ancient habitable environments, c) cache samples for eventual return to Earth, and d) demonstrate in-situ production of oxygen needed for human exploration. Remote-sensing instrumentation is needed to support the first three of these goals [1]. The SuperCam instrument meets these needs with a range of instrumentation including the highest-resolution remote imaging on the rover, two different techniques for determining mineralogy , and one technique to provide elemental compositions. All of these techniques are co-boresighted, providing rapid comprehensive characterization. In addition, for targets within 7 meters of the rover the laser shock waves brush away the dust, providing cleaner surfaces for analysis. SuperCam will use an advanced version of the AEGIS robotic target selection software
    corecore