10 research outputs found

    Coefficient of restitution for elastic disks

    Full text link
    We calculate the coefficient of restitution, ϵ\epsilon, starting from a microscopic model of elastic disks. The theory is shown to agree with the approach of Hertz in the quasistatic limit, but predicts inelastic collisions for finite relative velocities of two approaching disks. The velocity dependence of ϵ\epsilon is calculated numerically for a wide range of velocities. The coefficient of restitution furthermore depends on the elastic constants of the material via Poisson's number. The elastic vibrations absorb kinetic energy more effectively for materials with low values of the shear modulus.Comment: 25 pages, 12 Postscript figures, LaTex2

    Immunoassay screening in urine for synthetic cannabinoids – an evaluation of the diagnostic efficiency

    No full text
    Background: The abuse of synthetic cannabinoids (SCs) as presumed legal alternative to cannabis poses a great risk to public health. For economic reasons many laboratories use immunoassays (IAs) to screen for these substances in urine. However, the structural diversity and high potency of these designer drugs places high demands on IAs regarding cross-reactivity of the antibodies used and detection limits. Methods: Two retrospective studies were carried out in order to evaluate the capability of two homogenous enzyme IAs for the detection of currently prevalent SCs in authentic urine samples. Urine samples were analyzed utilizing a 'JWH-018' kit and a 'UR-144' kit. The IA results were confirmed by an up-to-date liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) screening method covering metabolites of 45 SCs. Results: The first study (n = 549) showed an 8% prevalence of SCs use (LC-MS/MS analysis) among inpatients of forensic-psychiatric clinics, whereas all samples were tested negative by the IAs. In a second study (n = 200) the combined application of both IAs led to a sensitivity of 2% and a diagnostic accuracy of 51% when applying the recommended IA cut-offs. Overall, 10 different currently prevalent SCs were detected in this population. The results can be explained by an insufficient cross-reactivity of the antibodies towards current SCs in combination with relatively high detection limits of the IAs. Conclusions: In light of the presented study data it is strongly recommended not to rely on the evaluated IA tests for SCs in clinical or forensic settings. For IA kits of other providers similar results can be expected

    Literaturverzeichnis

    No full text

    Literatur

    No full text
    corecore