706 research outputs found

    Field based reliability and validity of the Bioharness multivariable monitoring device

    Get PDF
    The BioharnessTM device is designed for monitoring physiological variables in free-living situations but has only been proven to be reliable and valid in a laboratory environment. Therefore, this study aimed to determine the reliability and validity of the BioharnessTM using a field based protocol. Twenty healthy males participated. Heart rate (HR), breathing frequency (BF) and accelerometry (ACC) were assessed by simultaneous measurement of two BioharnessTM devices and a test-retest of a discontinuous incremental walk-jog-run protocol (4 – 11 km·h-1) completed in a sports hall. Adopted precision of measurement devices were; HR: Polar T31 (Polar Electro), BF: Spirometer (Cortex Metalyser), ACC: Oxygen expenditure (Cortex Metalyser). For all data, precision of measurement reported good relationships (r = 0.61 to 0.67, p \u3c 0.01) and large Limits of Agreement for HR (\u3e79.2 b·min-1) and BF (\u3e54.7 br·min-1). ACC presented excellent precision (r = 0.94, p \u3c 0.01). Results for HR (r= ~0.91, p \u3c 0.01: CV \u3c7.6) and ACC (r \u3e 0.97, p \u3c 0.01; CV \u3c14.7) suggested these variables are reliable. BF presented more variable data (r = 0.46-0.61, p \u3c 0.01; CV \u3c 23.7). As velocity of movement increased (\u3e8 km·h-1) data became more erroneous. A data cleaning protocol removed gross errors in the data analysis and subsequent reliability and validity statistics improved across all variables. In conclusion, the BioharnessTM HR and ACC variables have demonstrated reliability and validity in a field setting, though data collected at higher velocities should be treated with caution. Measuring human physiological responses in a field based environment allows for more ecologically valid data to be collected and devices such as the BioharnessTM could be used by exercise professionals to begin to further investigate this area

    Field based reliability and validity of the Bioharness multivariable monitoring device

    Get PDF
    The Bioharnessℱ device is designed for monitoring physiological variables in free-living situations but has only been proven to be reliable and valid in a laboratory environment. Therefore, this study aimed to determine the reliability and validity of the Bioharnessℱ using a field based protocol. Twenty healthy males participated. Heart rate (HR), breathing frequency (BF) and accelerometry (ACC) were assessed by simultaneous measurement of two Bioharnessℱ devices and a test-retest of a discontinuous incremental walk-jog-run protocol (4 - 11 km·h-1) completed in a sports hall. Adopted precision of measurement devices were; HR: Polar T31 (Polar Electro), BF: Spirometer (Cortex Metalyser), ACC: Oxygen expenditure (Cortex Metalyser). For all data, precision of measurement reported good relationships (r = 0.61 to 0.67, p 79.2 b·min-1) and BF (>54.7 br·min-1). ACC presented excellent precision (r = 0.94, p 0.97, p 8 km·h-1) data became more erroneous. A data cleaning protocol removed gross errors in the data analysis and subsequent reliability and validity statistics improved across all variables. In conclusion, the Bioharnessℱ HR and ACC variables have demonstrated reliability and validity in a field setting, though data collected at higher velocities should be treated with caution. Measuring human physiological responses in a field based environment allows for more ecologically valid data to be collected and devices such as the Bioharnessℱ could be used by exercise professionals to begin to further investigate this area

    Physiological predictors of acute coronary syndromes: emerging insights from the plaque to the vulnerable patient

    Get PDF
    In this review, the authors explore the evolving evidence linking physiological assessment of coronary artery disease with plaque progression and vulnerability. Reducing adverse clinical events remains the ultimate goal for diagnostic tests, and this review highlights evidence supporting the prognostic value of physiological metrics in predicting outcomes. Historical and contemporary studies support synergy among lesion severity, ischemia, plaque vulnerability, and patient prognosis. Ischemia contributes to clinical events through association with plaque burden, but this review addresses the emerging concept that it associates with atherothrombosis via disturbed lesion hemodynamics. Biomechanical pathophysiological forces including endothelial shear stress-the frictional force generated by blood flow on the vessel wall-are increasingly linked with atherogenesis, vulnerable plaque morphology, and platelet and leukocyte activation. The authors conclude by transitioning from the model of the vulnerable plaque to the concept of the "vulnerable patient," looking more broadly at physiological contributors to Virchow's triad underpinning acute coronary syndrome

    On the Nature of the Phase Transition in SU(N), Sp(2) and E(7) Yang-Mills theory

    Full text link
    We study the nature of the confinement phase transition in d=3+1 dimensions in various non-abelian gauge theories with the approach put forward in [1]. We compute an order-parameter potential associated with the Polyakov loop from the knowledge of full 2-point correlation functions. For SU(N) with N=3,...,12 and Sp(2) we find a first-order phase transition in agreement with general expectations. Moreover our study suggests that the phase transition in E(7) Yang-Mills theory also is of first order. We find that it is weaker than for SU(N). We show that this can be understood in terms of the eigenvalue distribution of the order parameter potential close to the phase transition.Comment: 15 page

    Spin Glass Behavior in RuSr2Gd1.5Ce0.5Cu2O10

    Full text link
    The dynamics of the magnetic properties of polycrystalline RuSr2Gd1.5Ce0.5Cu2O10 (Ru-1222) have been studied by ac susceptibility and dc magnetization measurements, including relaxation and ageing studies. Ru-1222 is a reported magneto-superconductor with Ru spins magnetic ordering at temperatures near 100 K and superconductivity in Cu-O2 planes below Tc ~ 40 K. The exact nature of Ru spins magnetic ordering is still debated and no conclusion has been reached yet. In this work, a frequency-dependent cusp was observed in ac susceptibility vs. T measurements, which is interpreted as a spin glass transition. The change in the cusp position with frequency follows the Vogel-Fulcher law, which is commonly accepted to describe a spin glass with magnetically interacting clusters. Such interpretation is supported by themoremanaent magnetization (TRM) measurements at T = 60 K. TRM relaxations are well described by a stretched exponential relation, and present significant ageing effects.Comment: 4 pages, 6 figures, submitted to Phys. Rev.

    Cold Gas in Cluster Cores

    Full text link
    I review the literature's census of the cold gas in clusters of galaxies. Cold gas here is defined as the gas that is cooler than X-ray emitting temperatures (~10^7 K) and is not in stars. I present new Spitzer IRAC and MIPS observations of Abell 2597 (PI: Sparks) that reveal significant amounts of warm dust and star formation at the level of 5 solar masses per year. This rate is inconsistent with the mass cooling rate of 20 +/- 5 solar masses per year inferred from a FUSE [OVI] detection.Comment: 10 pages, conference proceeding

    Nurture, nature and some very dubious social skills: An interpretative phenomenological analysis of talent identification practices in elite English youth soccer

    Get PDF
    This paper reports qualitative findings regarding the concepts and practices utilised in talent identification (TI) among professional coaches working in English youth soccer. Using interpretative phenomenological analysis, detailed interviews with seven such coaches are explored, with a view to elucidating the links between understanding, practice, experience and professional context. Findings reveal three superordinate themes, relating to (1) a primarily ‘nurtured’ and trainable understanding of the broad concept of talent itself, (2) an ostensibly contradictory model of semi-static player psychology, and (3) a highly selective mechanism for separating evidence for ‘mental strength’ and ‘social skills’. It is contended that these findings underscore a case for more thorough interrogation of the real worlds inhabited by coaches, such that ideas about ‘good practice’ in TI might be more effectively reconciled with grounded knowledge of the practical everyday necessities of being a coach

    Fast variability from black-hole binaries

    Full text link
    Currently available information on fast variability of the X-ray emission from accreting collapsed objects constitutes a complex phenomenology which is difficult to interpret. We review the current observational standpoint for black-hole binaries and survey models that have been proposed to interpret it. Despite the complex structure of the accretion flow, key observational diagnostics have been identified which can provide direct access to the dynamics of matter motions in the close vicinity of black holes and thus to the some of fundamental properties of curved spacetimes, where strong-field general relativistic effects can be observed.Comment: 20 pages, 11 figures. Accepted for publication in Space Science Reviews. Also to appear in hard cover in the Space Sciences Series of ISSI "The Physics of Accretion onto Black Holes" (Springer Publisher

    Measurement of the B0-anti-B0-Oscillation Frequency with Inclusive Dilepton Events

    Get PDF
    The B0B^0-Bˉ0\bar B^0 oscillation frequency has been measured with a sample of 23 million \B\bar B pairs collected with the BABAR detector at the PEP-II asymmetric B Factory at SLAC. In this sample, we select events in which both B mesons decay semileptonically and use the charge of the leptons to identify the flavor of each B meson. A simultaneous fit to the decay time difference distributions for opposite- and same-sign dilepton events gives Δmd=0.493±0.012(stat)±0.009(syst)\Delta m_d = 0.493 \pm 0.012{(stat)}\pm 0.009{(syst)} ps−1^{-1}.Comment: 7 pages, 1 figure, submitted to Physical Review Letter
    • 

    corecore