44 research outputs found

    Response of Silicon photo-multipliers to a constant light flux

    Get PDF
    The response of a Silicon Photomultiplier to a constant illumination has been interpreted in term of Geiger- Mueller avalanche frequency, actually correlated to the photon flux via the photon detection efficiency. The hypothesis has been verified in laboratory tests and applied throughout the development of a device for real-time dosimetry in mammography

    Binary Sequences for Online Electrochemical Impedance Spectroscopy of Battery Cells

    Get PDF
    Online diagnostic of lithium-ion battery (LIB) cells may have significant impact on chemical energy storage systems. Electrochemical impedance spectroscopy (EIS) is widely used for the characterization of LIBs and could be the most appropriate technique for online diagnostic, but its response time should be shortened. This work investigates the usage of multisine excitation to shorten the measurement time and simplify the hardware implementation for EIS of battery cells. Two types of multisine binary sequences are considered: sigma-delta modulated multisine sequences (SDMSs) and maximum length binary sequences (MLBSs). Their applicability to online and in situ EIS monitoring is evaluated by designing a measurement architecture also suitable to be implemented in a system-on-chip. The calibrated measurement system is compared with a benchtop reference instrument, reporting an RMSE deviation smaller than 5% in the frequency range of interest 1-200 Hz. The realized system is then used for online monitoring of the discharge process of a commercial 18650 LIB cell. The two proposed sequences are compared in terms of accuracy using a digital battery emulator circuit. Both the sequences demonstrated to be suitable for fast measurement and simple hardware integration, enabling online in situ EIS monitoring at cell level

    3D atomic structure from a single XFEL pulse

    Full text link
    X-ray Free Electron Lasers (XFEL) are the most advanced pulsed x-ray sources. Their extraordinary pulse parameters promise unique applications. Indeed, several new methods have been developed at XFEL-s. However, no methods are known, which would allow ab initio atomic level structure determination using only a single XFEL pulse. Here, we present experimental results, demonstrating the determination of the 3D atomic structure from data obtained during a single 25 fs XFEL pulse. Parallel measurement of hundreds of Bragg reflections was done by collecting Kossel line patterns of GaAs and GaP. With these measurements, we reached the ultimate temporal limit of the x-ray structure solution possible today. These measurements open the way for studying non-repeatable fast processes and structural transformations in crystals for example measuring the atomic structure of matter at extremely non-ambient conditions or transient structures formed in irreversible physical, chemical, or biological processes. It would also facilitate time resolved pump-probe structural studies making them significantly shorter than traditional serial crystallography.Comment: 16 pages of manuscript followed by 15 pages of supplementary informatio

    Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter

    Full text link
    Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.Comment: 26 pages, 16 figures, JINST style, changes in the author list, typos corrected, new section added, figures regrouped. Accepted for publication in JINS

    Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

    Get PDF
    A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques

    Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter

    Get PDF
    The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from Geant4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.Comment: 38 pages, 19 figures, 5 tables; author list changed; submitted to JINS

    Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter

    Full text link
    We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.Comment: 35 pages, 21 figures, 8 table

    The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers

    Get PDF
    The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.Comment: 24 pages including author list, 9 figures, published in JINS

    Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter

    Get PDF
    A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.Comment: 28 pages, 24 figures, accepted for publication in NIM
    corecore