39 research outputs found

    Experimental study of short concrete columns reinforced with GFRP bars under monotonic loading

    Get PDF
    The glass fiber reinforced polymer (GFRP) bars are considered as an alternative reinforcement to steel in concrete structures subjected to chloride environment because of their non- corrosive and non-magnetic properties. To examine the applicability of GFRP bars to performance of concrete columns, this work was conducted. The effect of the compressive reinforcement ratio and stirrup spacing on the load carrying capacity of concrete columns reinforced with GFRP bars is experimentally investigated. Nine short concrete columns with dimensions of 150 × 150 × 600 mm were cast and tested until failure under displacement-controlled concentric loading. The experimental results demonstrated that by increasing the reinforcement ratio from 0.37% to 3.24%, the load-bearing capacity of GFRP RC columns was found to increase by an average of 28%. Moreover, the tested results confirmed that the GFRP stirrup spacing had a significant influence on the load-carrying capacity of the columns

    Experimental study of short concrete columns reinforced with GFRP bars under monotonic loading

    Get PDF
    The glass fiber reinforced polymer (GFRP) bars are considered as an alternative reinforcement to steel in concrete structures subjected to chloride environment because of their non- corrosive and non-magnetic properties. To examine the applicability of GFRP bars to performance of concrete columns, this work was conducted. The effect of the compressive reinforcement ratio and stirrup spacing on the load carrying capacity of concrete columns reinforced with GFRP bars is experimentally investigated. Nine short concrete columns with dimensions of 150 × 150 × 600 mm were cast and tested until failure under displacement-controlled concentric loading. The experimental results demonstrated that by increasing the reinforcement ratio from 0.37% to 3.24%, the load-bearing capacity of GFRP RC columns was found to increase by an average of 28%. Moreover, the tested results confirmed that the GFRP stirrup spacing had a significant influence on the load-carrying capacity of the columns

    Concrete beams using seawater and sea sand reinforced with steel and GFRP rebars exposed to marine environment: An experimental study

    Get PDF
    Using fresh water and river sand in concrete mix composition makes a lot of negative impacts on resources and the environment while the source of sea sand and sea water is abundant and less harmful to the environment. However, sea sand and seawater in concrete can cause severe corrosion of the reinforcement, reducing the durability and bearing capacity of the structure. This paper illustrates the results of a comparative study on the flexural behavior of six corroded seawater sea-sand concrete (SWSSC) beams. The corrosion process of two concrete beams reinforced with traditional steel bars and four concrete beams reinforced with a combination of glass fiber reinforced polymer (GFRP) and steel bars was coupled by the effect of seawater exposure and sustained load. It was found that after exposure to a marine environment during the period of 60 months the GFRP bar retains surface integrity, meanwhile, the steel bars were significantly corroded with a cross-sectional area loss of approximately 13.93%. The decrease in bending stiffness, yield load, and ultimate load of the RC beams was found due to the deterioration of SWSSC and corrosion of steel bars.

    Concrete beams using seawater and sea sand reinforced with steel and GFRP rebars exposed to marine environment: An experimental study

    Get PDF
    Using fresh water and river sand in concrete mix composition makes a lot of negative impacts on resources and the environment while the source of sea sand and sea water is abundant and less harmful to the environment. However, sea sand and seawater in concrete can cause severe corrosion of the reinforcement, reducing the durability and bearing capacity of the structure. This paper illustrates the results of a comparative study on the flexural behavior of six corroded seawater sea-sand concrete (SWSSC) beams. The corrosion process of two concrete beams reinforced with traditional steel bars and four concrete beams reinforced with a combination of glass fiber reinforced polymer (GFRP) and steel bars was coupled by the effect of seawater exposure and sustained load. It was found that after exposure to a marine environment during the period of 60 months the GFRP bar retains surface integrity, meanwhile, the steel bars were significantly corroded with a cross-sectional area loss of approximately 13.93%. The decrease in bending stiffness, yield load, and ultimate load of the RC beams was found due to the deterioration of SWSSC and corrosion of steel bars.

    LAND USE CHANGE AND RELATED PROBLEMS UNDER URBANIZATION IN SUBURBAN AREA OF HANOI CITY (A CASE STUDY OF HOANG LIET COMMUNE, THANH TRI DISTRICT)

    Full text link
    Joint Research on Environmental Science and Technology for the Eart

    Helicobacter pylori-Negative Gastric Mucosa-Associated Lymphoid Tissue Lymphoma in a Girl

    Get PDF
    Introduction: Extranodal marginal zone lymphoma (MZL) arises in a number of epithelial tissues, including the stomach, salivary gland, lung, small bowel, thyroid, ocular adnexa, skin, and elsewhere. It has also been called low-grade B-cell lymphoma of mucosa-associated lymphoid tissue (MALT). MALT lymphoma predominantly occurs in adults and is rare in children. Case Presentation: We report a case of MALT lymphoma involving the stomach, which is the most common subtype, in a 12-year-old girl. Initially, the patient relapsed after antibiotic therapy but achieved successful treatment subsequently through irradiation. Conclusion: Helicobacter pylori eradication therapy should be given to all patients with gastric MZL, irrespective of stage. In patients who do not respond to antibiotic therapy, treatment options such as irradiation and systemic cancer therapies should be considered, depending on the disease stage

    Safety and efficacy of fluoxetine on functional outcome after acute stroke (AFFINITY): a randomised, double-blind, placebo-controlled trial

    Get PDF
    Background Trials of fluoxetine for recovery after stroke report conflicting results. The Assessment oF FluoxetINe In sTroke recoverY (AFFINITY) trial aimed to show if daily oral fluoxetine for 6 months after stroke improves functional outcome in an ethnically diverse population. Methods AFFINITY was a randomised, parallel-group, double-blind, placebo-controlled trial done in 43 hospital stroke units in Australia (n=29), New Zealand (four), and Vietnam (ten). Eligible patients were adults (aged ≥18 years) with a clinical diagnosis of acute stroke in the previous 2–15 days, brain imaging consistent with ischaemic or haemorrhagic stroke, and a persisting neurological deficit that produced a modified Rankin Scale (mRS) score of 1 or more. Patients were randomly assigned 1:1 via a web-based system using a minimisation algorithm to once daily, oral fluoxetine 20 mg capsules or matching placebo for 6 months. Patients, carers, investigators, and outcome assessors were masked to the treatment allocation. The primary outcome was functional status, measured by the mRS, at 6 months. The primary analysis was an ordinal logistic regression of the mRS at 6 months, adjusted for minimisation variables. Primary and safety analyses were done according to the patient's treatment allocation. The trial is registered with the Australian New Zealand Clinical Trials Registry, ACTRN12611000774921. Findings Between Jan 11, 2013, and June 30, 2019, 1280 patients were recruited in Australia (n=532), New Zealand (n=42), and Vietnam (n=706), of whom 642 were randomly assigned to fluoxetine and 638 were randomly assigned to placebo. Mean duration of trial treatment was 167 days (SD 48·1). At 6 months, mRS data were available in 624 (97%) patients in the fluoxetine group and 632 (99%) in the placebo group. The distribution of mRS categories was similar in the fluoxetine and placebo groups (adjusted common odds ratio 0·94, 95% CI 0·76–1·15; p=0·53). Compared with patients in the placebo group, patients in the fluoxetine group had more falls (20 [3%] vs seven [1%]; p=0·018), bone fractures (19 [3%] vs six [1%]; p=0·014), and epileptic seizures (ten [2%] vs two [<1%]; p=0·038) at 6 months. Interpretation Oral fluoxetine 20 mg daily for 6 months after acute stroke did not improve functional outcome and increased the risk of falls, bone fractures, and epileptic seizures. These results do not support the use of fluoxetine to improve functional outcome after stroke

    Nhìn lại lịch sử

    No full text
    1134 tr. ; 21 c
    corecore