206 research outputs found
Quantum-enhanced gyroscopy with rotating anisotropic Bose–Einstein condensates
High-precision gyroscopes are a key component of inertial navigation systems. By considering matter wave gyroscopes that make use of entanglement it should be possible to gain some advantages in terms of sensitivity, size, and resources used over unentangled optical systems. In this paper we consider the details of such a quantum-enhanced atom interferometry scheme based on atoms trapped in a carefully-chosen rotating trap. We consider all the steps: entanglement generation, phase imprinting, and read-out of the signal and show that quantum enhancement should be possible in principle. While the improvement in performance over equivalent unentangled schemes is small, our feasibility study opens the door to further developments and improvements
Characterisation of the Gradient Coatings TiN/(Ti,Al,Si)N/TiN Type Deposited on Sintered Tool Materials
The paper presents results of the structural examinations, tests of mechanical and working properties ofthin wear resistant gradient coatings of the TiN/(Ti,Al,Si)N/TiN type, deposited in the CAE process ontothe substrate from the cermets and cemented carbides. Structural examinations are presented of theapplied coatings and their substrate made on the SEM, TEM and on the LM.Evaluation of the adhesion of the deposited coatings onto the cemented carbides and cermets was madeusing the scratch test. Cutting properties of the investigated materials were determined basing on thetechnological continuous cutting tests of the C45E steel. Substrate hardness tests and microhardness testsof the deposited coatings were made on the ultra-micro-hardness tester at 70 mN load. Surface roughnesstests were also made before depositing the coatings and after completing the PVD process
Entanglement production in Quantized Chaotic Systems
Quantum chaos is a subject whose major goal is to identify and to investigate
different quantum signatures of classical chaos. Here we study entanglement
production in coupled chaotic systems as a possible quantum indicator of
classical chaos. We use coupled kicked tops as a model for our extensive
numerical studies. We find that, in general, presence of chaos in the system
produces more entanglement. However, coupling strength between two subsystems
is also very important parameter for the entanglement production. Here we show
how chaos can lead to large entanglement which is universal and describable by
random matrix theory (RMT). We also explain entanglement production in coupled
strongly chaotic systems by deriving a formula based on RMT. This formula is
valid for arbitrary coupling strengths, as well as for sufficiently long time.
Here we investigate also the effect of chaos on the entanglement production for
the mixed initial state. We find that many properties of the mixed state
entanglement production are qualitatively similar to the pure state
entanglement production. We however still lack an analytical understanding of
the mixed state entanglement production in chaotic systems.Comment: 16 pages, 5 figures. To appear in Pramana:Journal of Physic
Photocatalytic activity of nanostructured anatase coatings obtained by cold gas spray
This article describes a photocatalytic nanostructured anatase coating deposited by cold gas spray (CGS)supported on titanium sub-oxide (TiO22x) coatings obtained by atmospheric plasma spray (APS) onto stainless steel cylinders. The photocatalytic coating was homogeneous and preserved the composition and nanostructure of the starting powder. The inner titanium sub-oxide coating favored the deposition of anatase particles in the solid state. Agglomerated nano-TiO2 particles fragmented when impacting onto the hard surface of the APS TiO22x bond coat. The rough surface provided by APS provided an ideal scenario for entrapping the nanostructured particles, which may be adhered onto the bond coat due to chemical bonding; a possible bonding mechanism is described. Photocatalytic experiments showed that CGS nano-TiO2 coating was active for photodegrading phenol and formic acid under aqueous conditions. The results were similar to the performance obtained by competitor technologies and materials such as dip-coating P25 photocatalysts. Disparity in the final performance of the photoactive materials may have been caused by differences in grain size and the crystalline composition of titanium dioxide
Minor and potentially toxic trace elements in milk and blood serum of dairy donkeys
The aim of this trial was to study the concentration of Ti, V, As, Rb, Sr, Mo, Cd, Cs, and Pb in donkey milk and blood serum. One hundred twelve individual milk and blood serum samples were collected from 16 lactating donkeys (Martina-Franca-derived population; 6 to 12 yr old; 3 to 7 parities; average live weight 205.4kg; 32 to 58 d after foaling at the beginning of the trial) during a 3-mo-long experiment. The samples were analyzed for the aforementioned elements by inductively coupled plasma-mass spectrometry. Feedstuff and drinking water were also analyzed for the investigated elements. Data were processed by ANOVA for repeated measures. Average milk concentrations (±SD) of Ti, Rb, Sr, Mo, Cs, and Pb were 77.3 (±7.7), 339.1 (±82.1), 881.7 (±270.4), 4.5 (±1.6), 0.49 (±0.09), and 3.2 (±2.7) μg/L, respectively. More than 80% of samples were below the limit of detection for V, As, and Cd in milk and for Cd, and Pb in blood serum. The lower bound calculated for milk V, As, and Cd was 0.03μg/L for the 3 elements, the upper bound was calculated at 0.23, 0.10, and 0.31μg/L and the maximum value was observed at 0.54, 0.15, and 0.51μg/L, respectively. The average milk concentrations of Ti, Rb, Sr, Mo, and Cs were 600, 458, 346, 16, and 294%, respectively, than those of blood serum. Yet, Cs concentrations were in the same order of magnitude in milk and serum. Moderate to strong positive and significant correlation coefficients were observed between milk and blood serum concentrations for Ti, Rb, Sr, and Cs. The effect of the stage of lactation was significant for all the investigated elements in milk and blood serum, but most of the elements showed only small changes or inconsistent trends, and only the concentrations of Rb and Sr showed decreasing trends both in milk and blood serum. The relationship between milk and blood serum element concentrations indicates that the mammary gland plays a role in determining the milk concentrations of Mo, Ti, Rb, Sr, Mo, and Cs. In the current experimental conditions, in agreement with the low levels in drinking water and feedstuff, donkey milk concentration of potentially toxic elements was very low and did not raise health concerns for human consumption
Influence of organic versus inorganic dietary selenium supplementation on the concentration of selenium in colostrum, milk and blood of beef cows
<p>Abstract</p> <p>Background</p> <p>Selenium (Se) is important for the postnatal development of the calf. In the first weeks of life, milk is the only source of Se for the calf and insufficient level of Se in the milk may lead to Se deficiency. Maternal Se supplementation is used to prevent this.</p> <p>We investigated the effect of dietary Se-enriched yeast (SY) or sodium selenite (SS) supplements on selected blood parameters and on Se concentrations in the blood, colostrum, and milk of Se-deficient Charolais cows.</p> <p>Methods</p> <p>Cows in late pregnancy received a mineral premix with Se (SS or SY, 50 mg Se per kg premix) or without Se (control – C). Supplementation was initiated 6 weeks before expected calving. Blood and colostrum samples were taken from the cows that had just calved (Colostral period). Additional samples were taken around 2 weeks (milk) and 5 weeks (milk and blood) after calving corresponding to Se supplementation for 6 and 12 weeks, respectively (Lactation period) for Se, biochemical and haematological analyses.</p> <p>Results</p> <p>Colostral period. Se concentrations in whole blood and colostrum on day 1 <it>post partum </it>and in colostrum on day 3 <it>post partum </it>were 93.0, 72.9, and 47.5 μg/L in the SY group; 68.0, 56.0 and 18.8 μg/L in the SS group; and 35.1, 27.3 and 10.5 μg/L in the C group, respectively. Differences among all the groups were significant (<it>P </it>< 0.01) at each sampling, just as the colostrum Se content decreases were from day 1 to day 3 in each group. The relatively smallest decrease in colostrum Se concentration was found in the SY group (<it>P </it>< 0.01).</p> <p>Lactation period. The mean Se concentrations in milk in weeks 6 and 12 of supplementation were 20.4 and 19.6 μg/L in the SY group, 8.3 and 11.9 μg/L in the SS group, and 6.9 and 6.6 μg/L in the C group, respectively. The values only differed significantly in the SS group (<it>P </it>< 0.05). The Se concentrations in the blood were similar to those of cows examined on the day of calving. The levels of glutathione peroxidase (GSH-Px) activity were 364.70, 283.82 and 187.46 μkat/L in the SY, SS, and C groups, respectively. This was the only significantly variable biochemical and haematological parameter.</p> <p>Conclusion</p> <p>Se-enriched yeast was much more effective than sodium selenite in increasing the concentration of Se in the blood, colostrum and milk, as well as the GSH-Px activity.</p
The elusive Heisenberg limit in quantum enhanced metrology
We provide efficient and intuitive tools for deriving bounds on achievable
precision in quantum enhanced metrology based on the geometry of quantum
channels and semi-definite programming. We show that when decoherence is taken
into account, the maximal possible quantum enhancement amounts generically to a
constant factor rather than quadratic improvement. We apply these tools to
derive bounds for models of decoherence relevant for metrological applications
including: dephasing,depolarization, spontaneous emission and photon loss.Comment: 10 pages, 4 figures, presentation imporved, implementation of the
semi-definite program finding the precision bounds adde
Non-Canonical NF-κB Activation and Abnormal B Cell Accumulation in Mice Expressing Ubiquitin Protein Ligase-Inactive c-IAP2
Loss of c-IAP2 ubiquitin ligase activity, which occurs in the lymphoma-causing c-IAP2/MALT1 fusion protein, activates non-canonical NF-κB signaling and results in B cell abnormalities characteristic of MALT lymphoma
Advances in quantum metrology
The statistical error in any estimation can be reduced by repeating the measurement and averaging the results. The central limit theorem implies that the reduction is proportional to the square root of the number of repetitions. Quantum metrology is the use of quantum techniques such as entanglement to yield higher statistical precision than purely classical approaches. In this Review, we analyse some of the most promising recent developments of this research field and point out some of the new experiments. We then look at one of the major new trends of the field: analyses of the effects of noise and experimental imperfections
- …