124 research outputs found

    Degenerative lumbar scoliosis: features and surgical treatment

    Get PDF
    Degenerative lumbar scoliosis is a de novo deformity of the spine occurring after the fourth or fifth decade of life in patients with no history of scoliosis in the growing age. We evaluated complications and functional and radiographic outcomes of twelve patients with degenerative lumbar scoliosis, treated by spinal decompression associated with posterolateral and/or interbody fusion. Mean lumbar scoliosis angle was 18\ub0 (SD=4\ub0) and mean age at surgery was 57 years (SD=6 years). Average follow\u2013up was 3.5 years. Surgical treatment consisted in decompression of one or more roots, associated with stabilization with pedicle screws and posterolateral fusion. To correct the deformity, the collapse of the disc was corrected by implanting a cage in the anterior interbody cage. Clinical symptoms and functional tolerance for daily activities improved after surgery. Radiographic evaluation showed a reduction in the deformity on the frontal and sagittal planes. There were no infections, evidence of pseudoarthrosis, instrumentrelated failures or re\u2013operations in this series. In patients with persisting pain caused by degenerative scoliosis associated with spinal stenosis, in whom conservative treatment has failed, spinal decompression and segmented fusion with instrumentation represents a valid treatment option

    Solution NMR studies of the plant peptide hormone CEP inform function

    Get PDF
    AbstractThe C-terminally Encoded Peptide (CEP) family of regulatory peptides controls root development in vascular plants. Here, we present the first NMR structures of CEP. We show that root-knot nematode (RKN: Meloidogyne spp.) also encodes CEP, presumably to mimic plant CEP as part of their stereotypic, parasitic interaction with vascular plants. Molecular dynamics simulations of plant- and nematode-encoded CEP displaying known posttranslational modifications (PTM) provided insight into the structural effects of PTM and the conformational plasticity and rigidity of CEP. Potential mechanisms of action are discussed with respect to the structure and sampling of conformational space

    Total knee replacements using rotating hinge implants in polio patients: clinical and functional outcomes

    Get PDF
    Little evidences are available in the literature concerning the outcomes of total knee replacement (TKR) in poliomyelitis patients with severe knee deformities or degeneration. Encouraging results have been reported concerning the use of constrained implants, i.e., rotating hinge knee prosthesis (RHK), compared to less constrained ones. The purpose of this paper is to report our experience with rotating hinge total knee replacement, using only RHK prosthesis, to determine functional results, complications, and survival of TKR in poliomyelitis patients. We performed a retrospective chart review of 14 patients with a history of knee osteoarthritis following poliomyelitis that underwent primary TKR, for a total of 15 surgical procedure (one bilateral case). Preoperative and postoperative clinical measurements have been conducted for all patients using the Knee Society Score (KSS). Hip-knee angle, recurvatum knee angle, and Insall-Salvati index were evaluated with full weight-bearing panoramic view X-ray preoperatively and postoperatively. The 2-year postoperative clinical KSS significantly improved from the preoperative scores. The average clinical KSS improved from 32,9 (range 3-48) preoperatively to 77,4 (range 60-88) postoperatively (P value < 0.005). The average functional KSS improved from 32,5 (range 10-60) preoperatively to 59,4 (range 30-95) postoperatively (P value < 0.005). TKR is a successful treatment in improving knee function and patient's quality of life. Using constrained implants, especially rotating hinge implants in polio patients with a quadriceps muscle weakness, could be a good alternative to maintain a physiological kinematics and reducing the revision rate due to knee instability

    Osteochondral impaction of the posterior acetabular surface without cortical fracture of any wall or column: an undescribed pattern of acetabular injury

    Get PDF
    Surgical treatment of a unusual acetabular fracture is described. This fracture was characterized by impaction and breaking down of the posterior articular surface and comminution of lamina quadrilatera lower portion, without cortical fracture of both columns. The fracture was treated surgically through the Kocher–Langenbeck approach. A small hole was created in the acetabulum posterior wall, the impacted fragment was reduced, and the bone defect was filled with autologous bone from the greater trochanter. A plate was shaped in order to fix both bone graft and fractured fragment

    Biomarker phenotyping drives clinical management in axillary sentinel node: A retrospective study on women with primary breast cancer in 2002

    Get PDF
    The current study examined if cancer biomarker phenotyping could predict the clinical/pathological status of axillary nodes in women with primary breast cancer. Primary breast cancers from 2002 were analyzed for tumor size, estrogen receptor (ER), progesterone receptor (PgR), Ki.67MIB expression and Her2/neu amplification. Relationships between the clinical and pathological status of the axilla and the biological subtypes classification were analyzed using univariate, multivariate and regression tree analysis. A total of 65% of women with axillary nodes clinically involved had complete axillary node dissection (ALND) while 705 women with clinically negative axillary underwent sentinel lymph node biopsy (SLNB), 18.5% of the latter had at least one pathologically SLNB involved node. Multivariate analysis revealed that the Luminal A subtype was significantly associated (OR 0.62; P<10-9) with clinical negative axilla while HER2pos/not Luminal was associated with clinical positivity (OR 1.71; P<0.01). No significant association between biological subtypes and SLNB status was demonstrated. Regression tree analysis revealed that subgroups with significantly different probability of SLNB status were separated according to tumor size and PgR values. In conclusion, the current study demonstrated that biomarker breast cancer phenotyping is significantly associated with clinical status of axillary nodes but not with pathological involvement of nodes at SLNB. Regression tree analysis could represent a valid attempt to individualize some patients subgroups candidate to different surgical axilla approaches

    Improving procedural fidelity of behavioural interventions for people with intellectual and developmental disabilities: A systematic review

    Get PDF
    Background: Despite its importance within behavioural intervention, it remains unclear how best to achieve high procedural fidelity. This paper reviewed studies on improving procedural fidelity of behavioural interventions for individuals with intellectual and developmental disabilities (IDD). Method: A systematic literature search was conducted, which identified 20 studies meeting inclusion criteria. Data were extracted on study design, participant characteristics, intervention, target behaviours, effect sizes, maintenance, generalisation, and social validity. A quality rating was also applied. Results: A total of 100 participants took part in the included studies. Most participants were teachers working with children in school settings. There was a significant positive correlation between level of procedural fidelity and client outcomes. Feedback was the most commonly employed intervention to improve procedural fidelity. Conclusions: More research should be conducted in environments with high levels of variability such as community homes to determine how to reach and maintain high levels of procedural fidelity

    Weak Lensing from Space I: Instrumentation and Survey Strategy

    Full text link
    A wide field space-based imaging telescope is necessary to fully exploit the technique of observing dark matter via weak gravitational lensing. This first paper in a three part series outlines the survey strategies and relevant instrumental parameters for such a mission. As a concrete example of hardware design, we consider the proposed Supernova/Acceleration Probe (SNAP). Using SNAP engineering models, we quantify the major contributions to this telescope's Point Spread Function (PSF). These PSF contributions are relevant to any similar wide field space telescope. We further show that the PSF of SNAP or a similar telescope will be smaller than current ground-based PSFs, and more isotropic and stable over time than the PSF of the Hubble Space Telescope. We outline survey strategies for two different regimes - a ``wide'' 300 square degree survey and a ``deep'' 15 square degree survey that will accomplish various weak lensing goals including statistical studies and dark matter mapping.Comment: 25 pages, 8 figures, 1 table, replaced with Published Versio

    Deep Underground Science and Engineering Laboratory - Preliminary Design Report

    Full text link
    The DUSEL Project has produced the Preliminary Design of the Deep Underground Science and Engineering Laboratory (DUSEL) at the rehabilitated former Homestake mine in South Dakota. The Facility design calls for, on the surface, two new buildings - one a visitor and education center, the other an experiment assembly hall - and multiple repurposed existing buildings. To support underground research activities, the design includes two laboratory modules and additional spaces at a level 4,850 feet underground for physics, biology, engineering, and Earth science experiments. On the same level, the design includes a Department of Energy-shepherded Large Cavity supporting the Long Baseline Neutrino Experiment. At the 7,400-feet level, the design incorporates one laboratory module and additional spaces for physics and Earth science efforts. With input from some 25 science and engineering collaborations, the Project has designed critical experimental space and infrastructure needs, including space for a suite of multidisciplinary experiments in a laboratory whose projected life span is at least 30 years. From these experiments, a critical suite of experiments is outlined, whose construction will be funded along with the facility. The Facility design permits expansion and evolution, as may be driven by future science requirements, and enables participation by other agencies. The design leverages South Dakota's substantial investment in facility infrastructure, risk retirement, and operation of its Sanford Laboratory at Homestake. The Project is planning education and outreach programs, and has initiated efforts to establish regional partnerships with underserved populations - regional American Indian and rural populations

    Measurement of the angular correlation between the two gamma rays emitted in the radioactive decays of a 60^{60}Co source with two NaI(Tl) scintillator

    Full text link
    We implemented a didactic experiment to study the angular correlation between the two gamma rays emitted in typical 60^{60}Co radioactive decays. We used two NaI(Tl) scintillators, already available in our laboratory, and a low-activity 60^{60}Co source. The detectors were mounted on two rails, with the source at their center. The first rail was fixed, while the second could be rotated around the source. We performed several measurements by changing the angle between the two scintillators in the range from 9090^\circ to 180180^\circ. Dedicated background runs were also performed, removing the source from the experimental setup. We found that the signal rate increases with the angular separation between the two scintillators, with small discrepancies from the theoretical expectations.Comment: 15 pages, 12 figure

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead
    corecore