10 research outputs found

    Diagnosis of tuberculosis infection using interferon-Îł-based assays

    Get PDF
    Interferon-Îł-based assays, collectively known as IFN-Îł release assays (IGRAs), have emerged as a reliable alternative to the old tuberculin skin test (TST) for the immunodiagnosis of tuberculosis (TB) infection. The 2 commercially available tests, the enzyme-linked immunosorbent assay (ELISA), QuantiFERON-TB Gold Intube (QFT-IT), and the enzyme-linked immunospot assay (ELISPOT), T-SPOT.TB, are more accurate than TST for the diagnosis of TB, since they are highly specific and correlate better with the existence of risk factors for the infection. According to the available data, T-SPOT.TB obtains a higher number of positive results than QFT-IT, while its specificity seems to be lower. Although the sensitivity of the IFN-Îł -based assays may be impaired to some extent by cellular immunosuppression and extreme ages of life, they perform better than TST in these situations. Data from longitudinal studies suggest that IFN-Îł-based tests are better predictors of subsequent development of active TB than TST; however this prognostic value has not been consistently demonstrated. This review focuses on the clinical use of the IFN-Îł -based tests in different risk TB groups, and notes the main limitations and areas for future development

    Predictors of persistently positive Mycobacterium-tuberculosis-specific interferon-gamma responses in the serial testing of health care workers

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Data on the performance of Mycobacterium-tuberculosis-specific interferon-(IFN)-Îł release assays (IGRAs) in the serial testing of health care workers (HCWs) is limited. The objective of the present study was to determine the frequency of IGRA conversions and reversions and to identify predictors of persistent IGRA positivity among serially tested German HCWs in the absence of recent extensive tuberculosis (TB) exposure.</p> <p>Methods</p> <p>In this observational cohort-study HCWs were prospectively recruited within occupational safety and health measures and underwent a tuberculin skin test (TST) and the IGRA QuantiFERON<sup>Âź</sup>-TB Gold In-Tube (QFT-GIT) at baseline. The QFT-GIT was repeated 18 weeks later in the median. QFT-GIT conversions (and reversions) were defined as baseline IFN-Îł < 0.35 IU/ml and follow-up IFN-Îł ≄ 0.35 IU/ml (and vice versa). Predictors of persistently positive QFT-GIT results were calculated by logistic regression analysis.</p> <p>Results</p> <p>In total, 18 (9.9%) and 15 (8.2%) of 182 analyzed HCWs were QFT-GIT-positive at baseline and at follow-up, respectively. We observed a strong overall agreement between baseline and follow-up QFT-GIT results (Îș = 0.70). Reversions (6/18, 33.3%) occurred more frequently than conversions (3/162, 1.9%). Age and positive prior and recent TST results independently predicted persistent QFT-GIT positivity. Furthermore, the chance of having persistently positive QFT-GIT results raised about 3% with each additional 0.1 IU/ml increase in the baseline IFN-Îł response (adjusted odds ratio 1.03, 95% confidence interval 1.01-1.04). No active TB cases were detected within an observational period of more than two years.</p> <p>Conclusions</p> <p>The QFT-GIT's utility for the application in serial testing was limited by a substantial proportion of reversions. This shortcoming could be overcome by the implementation of a borderline zone for the interpretation of QFT-GIT results. However, further studies are needed to clearly define the within-subject variability of the QFT-GIT and to confirm that increasing age, concordantly positive TST results, and the extend of baseline IFN-Îł responses may predict the persistence of QFT-GIT positivity over time in serially tested HCWs with only a low or medium TB screening risk in a TB low-incidence setting.</p

    Integrating volunteers into rescue processes: analysis of user requirements and mobile app conception

    No full text
    Recently, rescue worker resources have not been sufficient to meet the regular response time during large-scale catastrophic events in every case. However, many volunteers supported official forces in different disaster situations, often self-organized through social media. In this paper, a system will be introduced which allows the coordination of trained volunteers by a professional control center with the objective of a more efficient distribution of human resources and technical equipment. Volunteers are contacted via app on their private smartphone. The design of this app is based on user requirements gathered in focus group discussions. The feedback of the potential users includes privacy aspects, low energy consumption, and mechanisms for long-term motivation and training. The authors present the results of the focus group analyses as well as the transfer to their app design concept

    Perception of Barriers to Immunization Among Parents of Hmong Origin in California

    No full text
    Objectives. We explored factors associated with perception of barriers to immunization among parents of Hmong origin in California, whose children experience persistent immunization inequities even with health insurance

    Within-Subject Variability of Mycobacterium tuberculosis-Specific Gamma Interferon Responses in German Health Care Workers ▿

    No full text
    Gamma interferon (IFN-γ) release assays (IGRAs) are used increasingly for the periodic tuberculosis (TB) screening of health care workers (HCWs), although data regarding the reproducibility and interpretation of serial testing results in countries with a low incidence of TB are scarce. The present study evaluated and compared the within-subject variability of dichotomous and continuous results of two commercial IGRAs, the QuantiFERON-TB Gold In-Tube (QFT) and the T-SPOT.TB (T-SPOT), in German HCWs during a 4-week period. Thirty-five immunocompetent HCWs with low or medium TB screening risk and without known recent TB exposure or tuberculin skin test application were tested repeatedly with both IGRAs at weekly intervals. A total of 158 valid results were obtained for each IGRA. Changes of about ±70% (QFT) and ±60% (T-SPOT) from the mean IFN-γ response accounted for 95% of the within-subject variability. However, according to the manufacturers' cutoffs, inconsistent results were observed more frequently for the QFT (28.6%; four conversions, six reversions) than for the T-SPOT (8.6%; three reversions; P < 0.001). The overall agreement between the IGRAs was good. Regression toward the means accounted for a significant decline in mean IFN-γ responses of about 25% between successive visits for both IGRAs. Although both assays were highly reliable and reproducible, we observed substantial within-subject variability and regression toward the means during a 4-week period, which should be considered when interpreting serial testing results in comparable populations and settings. Our data support the use of borderline zones for the interpretation of serial IGRA results and the retesting of borderline positive results before offering preventive chemotherapy
    corecore