44 research outputs found

    Why Are Outcomes Different for Registry Patients Enrolled Prospectively and Retrospectively? Insights from the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF).

    Get PDF
    Background: Retrospective and prospective observational studies are designed to reflect real-world evidence on clinical practice, but can yield conflicting results. The GARFIELD-AF Registry includes both methods of enrolment and allows analysis of differences in patient characteristics and outcomes that may result. Methods and Results: Patients with atrial fibrillation (AF) and ≄1 risk factor for stroke at diagnosis of AF were recruited either retrospectively (n = 5069) or prospectively (n = 5501) from 19 countries and then followed prospectively. The retrospectively enrolled cohort comprised patients with established AF (for a least 6, and up to 24 months before enrolment), who were identified retrospectively (and baseline and partial follow-up data were collected from the emedical records) and then followed prospectively between 0-18 months (such that the total time of follow-up was 24 months; data collection Dec-2009 and Oct-2010). In the prospectively enrolled cohort, patients with newly diagnosed AF (≀6 weeks after diagnosis) were recruited between Mar-2010 and Oct-2011 and were followed for 24 months after enrolment. Differences between the cohorts were observed in clinical characteristics, including type of AF, stroke prevention strategies, and event rates. More patients in the retrospectively identified cohort received vitamin K antagonists (62.1% vs. 53.2%) and fewer received non-vitamin K oral anticoagulants (1.8% vs . 4.2%). All-cause mortality rates per 100 person-years during the prospective follow-up (starting the first study visit up to 1 year) were significantly lower in the retrospective than prospectively identified cohort (3.04 [95% CI 2.51 to 3.67] vs . 4.05 [95% CI 3.53 to 4.63]; p = 0.016). Conclusions: Interpretations of data from registries that aim to evaluate the characteristics and outcomes of patients with AF must take account of differences in registry design and the impact of recall bias and survivorship bias that is incurred with retrospective enrolment. Clinical Trial Registration: - URL: http://www.clinicaltrials.gov . Unique identifier for GARFIELD-AF (NCT01090362)

    Risk profiles and one-year outcomes of patients with newly diagnosed atrial fibrillation in India: Insights from the GARFIELD-AF Registry.

    Get PDF
    BACKGROUND: The Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF) is an ongoing prospective noninterventional registry, which is providing important information on the baseline characteristics, treatment patterns, and 1-year outcomes in patients with newly diagnosed non-valvular atrial fibrillation (NVAF). This report describes data from Indian patients recruited in this registry. METHODS AND RESULTS: A total of 52,014 patients with newly diagnosed AF were enrolled globally; of these, 1388 patients were recruited from 26 sites within India (2012-2016). In India, the mean age was 65.8 years at diagnosis of NVAF. Hypertension was the most prevalent risk factor for AF, present in 68.5% of patients from India and in 76.3% of patients globally (P < 0.001). Diabetes and coronary artery disease (CAD) were prevalent in 36.2% and 28.1% of patients as compared with global prevalence of 22.2% and 21.6%, respectively (P < 0.001 for both). Antiplatelet therapy was the most common antithrombotic treatment in India. With increasing stroke risk, however, patients were more likely to receive oral anticoagulant therapy [mainly vitamin K antagonist (VKA)], but average international normalized ratio (INR) was lower among Indian patients [median INR value 1.6 (interquartile range {IQR}: 1.3-2.3) versus 2.3 (IQR 1.8-2.8) (P < 0.001)]. Compared with other countries, patients from India had markedly higher rates of all-cause mortality [7.68 per 100 person-years (95% confidence interval 6.32-9.35) vs 4.34 (4.16-4.53), P < 0.0001], while rates of stroke/systemic embolism and major bleeding were lower after 1 year of follow-up. CONCLUSION: Compared to previously published registries from India, the GARFIELD-AF registry describes clinical profiles and outcomes in Indian patients with AF of a different etiology. The registry data show that compared to the rest of the world, Indian AF patients are younger in age and have more diabetes and CAD. Patients with a higher stroke risk are more likely to receive anticoagulation therapy with VKA but are underdosed compared with the global average in the GARFIELD-AF. CLINICAL TRIAL REGISTRATION-URL: http://www.clinicaltrials.gov. Unique identifier: NCT01090362

    Improved risk stratification of patients with atrial fibrillation: an integrated GARFIELD-AF tool for the prediction of mortality, stroke and bleed in patients with and without anticoagulation.

    Get PDF
    OBJECTIVES: To provide an accurate, web-based tool for stratifying patients with atrial fibrillation to facilitate decisions on the potential benefits/risks of anticoagulation, based on mortality, stroke and bleeding risks. DESIGN: The new tool was developed, using stepwise regression, for all and then applied to lower risk patients. C-statistics were compared with CHA2DS2-VASc using 30-fold cross-validation to control for overfitting. External validation was undertaken in an independent dataset, Outcome Registry for Better Informed Treatment of Atrial Fibrillation (ORBIT-AF). PARTICIPANTS: Data from 39 898 patients enrolled in the prospective GARFIELD-AF registry provided the basis for deriving and validating an integrated risk tool to predict stroke risk, mortality and bleeding risk. RESULTS: The discriminatory value of the GARFIELD-AF risk model was superior to CHA2DS2-VASc for patients with or without anticoagulation. C-statistics (95% CI) for all-cause mortality, ischaemic stroke/systemic embolism and haemorrhagic stroke/major bleeding (treated patients) were: 0.77 (0.76 to 0.78), 0.69 (0.67 to 0.71) and 0.66 (0.62 to 0.69), respectively, for the GARFIELD-AF risk models, and 0.66 (0.64-0.67), 0.64 (0.61-0.66) and 0.64 (0.61-0.68), respectively, for CHA2DS2-VASc (or HAS-BLED for bleeding). In very low to low risk patients (CHA2DS2-VASc 0 or 1 (men) and 1 or 2 (women)), the CHA2DS2-VASc and HAS-BLED (for bleeding) scores offered weak discriminatory value for mortality, stroke/systemic embolism and major bleeding. C-statistics for the GARFIELD-AF risk tool were 0.69 (0.64 to 0.75), 0.65 (0.56 to 0.73) and 0.60 (0.47 to 0.73) for each end point, respectively, versus 0.50 (0.45 to 0.55), 0.59 (0.50 to 0.67) and 0.55 (0.53 to 0.56) for CHA2DS2-VASc (or HAS-BLED for bleeding). Upon validation in the ORBIT-AF population, C-statistics showed that the GARFIELD-AF risk tool was effective for predicting 1-year all-cause mortality using the full and simplified model for all-cause mortality: C-statistics 0.75 (0.73 to 0.77) and 0.75 (0.73 to 0.77), respectively, and for predicting for any stroke or systemic embolism over 1 year, C-statistics 0.68 (0.62 to 0.74). CONCLUSIONS: Performance of the GARFIELD-AF risk tool was superior to CHA2DS2-VASc in predicting stroke and mortality and superior to HAS-BLED for bleeding, overall and in lower risk patients. The GARFIELD-AF tool has the potential for incorporation in routine electronic systems, and for the first time, permits simultaneous evaluation of ischaemic stroke, mortality and bleeding risks. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier for GARFIELD-AF (NCT01090362) and for ORBIT-AF (NCT01165710)

    Two-year outcomes of patients with newly diagnosed atrial fibrillation: results from GARFIELD-AF.

    Get PDF
    AIMS: The relationship between outcomes and time after diagnosis for patients with non-valvular atrial fibrillation (NVAF) is poorly defined, especially beyond the first year. METHODS AND RESULTS: GARFIELD-AF is an ongoing, global observational study of adults with newly diagnosed NVAF. Two-year outcomes of 17 162 patients prospectively enrolled in GARFIELD-AF were analysed in light of baseline characteristics, risk profiles for stroke/systemic embolism (SE), and antithrombotic therapy. The mean (standard deviation) age was 69.8 (11.4) years, 43.8% were women, and the mean CHA2DS2-VASc score was 3.3 (1.6); 60.8% of patients were prescribed anticoagulant therapy with/without antiplatelet (AP) therapy, 27.4% AP monotherapy, and 11.8% no antithrombotic therapy. At 2-year follow-up, all-cause mortality, stroke/SE, and major bleeding had occurred at a rate (95% confidence interval) of 3.83 (3.62; 4.05), 1.25 (1.13; 1.38), and 0.70 (0.62; 0.81) per 100 person-years, respectively. Rates for all three major events were highest during the first 4 months. Congestive heart failure, acute coronary syndromes, sudden/unwitnessed death, malignancy, respiratory failure, and infection/sepsis accounted for 65% of all known causes of death and strokes for <10%. Anticoagulant treatment was associated with a 35% lower risk of death. CONCLUSION: The most frequent of the three major outcome measures was death, whose most common causes are not known to be significantly influenced by anticoagulation. This suggests that a more comprehensive approach to the management of NVAF may be needed to improve outcome. This could include, in addition to anticoagulation, interventions targeting modifiable, cause-specific risk factors for death. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov. Unique identifier: NCT01090362

    Implementation of harmonic propagation damping feature on a storage and grid support equipment.

    No full text
    Este trabalho trata do amortecimento de propaga??o harm?nica em linhas de distribui??o, visando melhora na qualidade da tens?o. A propaga??o harm?nica ocorre devido ?s resson?ncias entre as imped?ncias indutivas do sistema e bancos de capacitores utilizados em filtros passivos e compensadores de reativos, amplificando a distor??o causada por cargas n?o lineares nas proximidades, e pode ser amortecida atrav?s do uso de filtros ativos emulando resist?ncias harm?nicas. Esta abordagem (ao inv?s do uso convencional dos filtros ativos shunt para diretamente compensar as correntes harm?nicas) ? muito atrativa para sistemas de distribui??o, aonde as cargas n?o lineares est?o distribu?das e inacess?veis. A contribui??o principal deste artigo ? a implementa??o desta resist?ncia harm?nica em um equipamento de armazenamento de energia e suporte de rede como uma funcionalidade extra, sem necessidade de sensores adicionais. Resultados experimentais s?o apresentados em uma bancada de testesThis work discusses harmonic propagation damping on distribution lines, aiming for better voltage quality. The harmonic propagation is due to resonances between the inductive impedances of the system and the capacitor banks installed in passive filters and reactive power compensators, amplifying the distortion caused by non-linear loads nearby, and can be damped with the use of active filters emulating harmonic resistances. This approach (instead of the conventional use of shunt active filters to directly compensate harmonic currents) is very attractive for distribution systems, where the non-linear loads are distributed and inaccessible. The main contribution of this paper is the implementation of this harmonic resistance in an energy storage and grid support equipment as an extra feature, without the need of additional sensors. Experimental results are presented in a test bench

    Development and 24 Hour Behavior Analysis of a Peak-Shaving Equipment with Battery Storage

    No full text
    This paper presents the development of a peak-shaving equipment, composed by a multilevel converter in a cascaded H-bridge topology and battery banks on the DC links. Between specific time periods, when the demand is higher, the equipment injects active power from the batteries into the grid to provide support to the system. During the other times of the day, when the demand is lower, the converter charges its battery banks with the exceeding (and low producing cost) energy from the grid. The charge and discharge control algorithms are implemented in a digital signal processor (DSP). The precise time of the day information is obtained from a real-time-clock from a global positioning system module (GPS), which communicates with the DSP through the serial interface. This paper presents the control algorithms and experimental results obtained in a 24 h continuous operation of the equipment

    Real-World Outcomes of Autologous and Allogeneic Hematopoietic Stem Cell Transplantation for Relapsed/Refractory Hodgkin Lymphoma in the Era of Novel Therapies: A Canadian Perspective

    No full text
    Despite high cure rates with frontline therapy for Hodgkin lymphoma (HL), approximately 30% of patients will relapse or develop primary refractory disease (R/r). Autologous hematopoietic stem cell transplantation (autoHSCT) is the standard of care for R/r disease, and allogeneic HSCT (alloHSCT) is a curative option for patients in second relapse. Novel agents are being incorporated for the treatment of R/r HL, such that the optimal timing of transplantation is currently being challenged. In this rapidly evolving field, we sought to offer a Canadian perspective on the optreatment of R/r HL and demonstrate the role and effectiveness of both autoHSCT and alloHSCT for the treatment of R/r HL. This single-center retrospective study examined outcomes in 89 consecutive patients with R/r HL treated with autoHSCT between January 2007 and December 2019. A total of 17 patients underwent alloHSCT either as a tandem auto-allo approach or as salvage therapy. With a median follow-up of 5.0 years, the estimated 5-year PFS and OS for patients undergoing autoHSCT were 57.5% (95% confidence interval [CI], 45.2% to 68.0%) and 81.3% (95% CI, 70.0% to 88.8%), respectively. Corresponding values for patients who underwent alloHSCT were 76.5% (95% CI, 48.8% to 90.4%) and 82.4% (95% CI, 54.7% to 93.9%). Nonrelapse mortality at 0% at 100 days and 9.4% at 5 years post-autoHSCT and 0% and 5.9%, respectively, post-alloHSCT. The cumulative incidence of acute graft-versus-host disease (GVHD) at day +100 was 35.3% (95% CI, 17.7% to 62.3%), and that of chronic GVHD at 1 year was 23.5% (95% CI, 6.9% to 45.8%). Both autoHSCT and alloHSCT provide robust and prolonged disease control New agents should be used as a bridge to improve the curative potential of these definitive cellular therapies
    corecore