158 research outputs found
Observation of longitudinal and transverse self-injections in laser-plasma accelerators
Laser-plasma accelerators can produce high quality electron beams, up to
giga-electronvolts in energy, from a centimeter scale device. The properties of
the electron beams and the accelerator stability are largely determined by the
injection stage of electrons into the accelerator. The simplest mechanism of
injection is self-injection, in which the wakefield is strong enough to trap
cold plasma electrons into the laser wake. The main drawback of this method is
its lack of shot-to-shot stability. Here we present experimental and numerical
results that demonstrate the existence of two different self-injection
mechanisms. Transverse self-injection is shown to lead to low stability and
poor quality electron beams, because of a strong dependence on the intensity
profile of the laser pulse. In contrast, longitudinal injection, which is
unambiguously observed for the first time, is shown to lead to much more stable
acceleration and higher quality electron beams.Comment: 7 pages, 7 figure
Angular momentum evolution in laser-plasma accelerators
The transverse properties of an electron beam are characterized by two
quantities, the emittance which indicates the electron beam extend in the phase
space and the angular momentum which allows for non-planar electron
trajectories. Whereas the emittance of electron beams produced in laser- plasma
accelerator has been measured in several experiments, their angular momentum
has been scarcely studied. It was demonstrated that electrons in laser-plasma
accelerator carry some angular momentum, but its origin was not established.
Here we identify one source of angular momentum growth and we present
experimental results showing that the angular momentum content evolves during
the acceleration
Effect of experimental laser imperfections on laser wakefield acceleration and betatron source
International audienceLaser pulses in current ultra-short TW systems are far from being ideal Gaussian beams. The influence of the presence of non-Gaussian features of the laser pulse is investigated here from experiments and 3D Particle-in-Cell simulations. Both the experimental intensity distribution and wavefront are used as input in the simulations. It is shown that a quantitative agreement between experimental data and simulations requires to use realistic pulse features. Moreover, some trends found in the experiments, such as the growing of the X-ray signal with the plasma length, can only be retrieved in simulations with realistic pulses. The performances on the electron acceleration and the synchrotron X-ray emission are strongly degraded by these non-Gaussian features, even keeping constant the total laser energy. A drop on the X-ray photon number by one order of magnitude was found. This clearly put forward the limitation of using a Gaussian beam in the simulations
Phenotype of autosomal dominant spastic paraplegia linked to chromosome 2
Summary We report the clinical features of 12 families with autosomal dominant spastic paraplegia (ADSP) linked to the SPG4 locus on chromosome 2p, the major locus for this disorder that accounts for ∼40% of the families. Among 93 gene carriers, 32 (34%) were unaware of symptoms but were clinically affected. Haplotype reconstruction showed that 90% of the asymptomatic gene carriers presented increased reflexes and/or extensor plantar responses independent of age at examination. The mean age at onset was 29 years, ranging from 1 to 63 years. Intra- as well as inter-familial variability of age at onset was important, but did not result from anticipation. Phenotype—genotype correlations and comparison with SPG3 and SPG5 families indicated that despite the variability of age at onset, SPG4 is a single genetic entity but no clinical features distinguish individual SPG4 patients from those with SPG3 or SPG5 mutation
Les immunothérapies spécifiques dans le traitement des cancers
The offer of anti-cancer drugs has recently been disrupted by the introduction of checkpoint inhibitors on the market. Currently, one anti-CTLA-4, two anti-PD-1 and two anti-PD-L1 are authorized in the European Union, in seven different types of cancer. The clinical development of these therapies is still in full swing: in July 2017, more than 1 500 clinical trials were evaluating anti-PD-1, anti-PD-L1 and anti-CTLA-4 drugs in about twenty different locations and this number continues to increase. In the short term in France, other immunotherapies, the CAR-T cells, will complete this therapeutic arsenal. These immunotherapies appear as a real revolution in the treatment of some cancers. Nevertheless, many issues are associated with these therapies, particularly regarding the identification of good responders, the proper use of these drugs including the management of therapeutic strategies and safety profile, as well as the organization of care. In addition, the expenses associated with ipilimumab, nivolumab and pembrolizumab are substantial and almost tripled in one year, going from 120 million euros in 2015 to more than 340 million euros in 2016. This raises the question of the ability of the current healthcare system to maintain equitable access to innovation and best treatments for all patients. For all these reasons, the French National Cancer Institute decided to dedicate its thematic annual report on these innovative immunotherapies, targeting in particular checkpoint inhibitors and CAR-T cells, in order to produce an inventory of current data and an analysis regarding the different issues associated with these therapies
High-Flux Femtosecond X-Ray Emission from Controlled Generation of Annular Electron Beams in a Laser Wakefield Accelerator
Annular quasimonoenergetic electron beams with a mean energy in the range 200-400 MeV and charge on the order of several picocoulombs were generated in a laser wakefield accelerator and subsequently accelerated using a plasma afterburner in a two-stage gas cell. Generation of these beams is associated with injection occurring on the density down ramp between the stages. This well-localized injection produces a bunch of electrons performing coherent betatron oscillations in the wakefield, resulting in a significant increase in the x-ray yield. Annular electron distributions are detected in 40% of shots under optimal conditions. Simultaneous control of the pulse duration and frequency chirp enables optimization of both the energy and the energy spread of the annular beam and boosts the radiant energy per unit charge by almost an order of magnitude. These well-defined annular distributions of electrons are a promising source of high-brightness laser plasma-based x rays
Spatiotemporal dynamics of ultrarelativistic beam-plasma instabilities
An electron or electron-positron beam streaming through a plasma is
notoriously prone to micro-instabilities. For a dilute ultrarelativistic
infinite beam, the dominant instability is a mixed mode between longitudinal
two-stream and transverse filamentation modes, with a phase velocity oblique to
the beam velocity. A spatiotemporal theory describing the linear growth of this
oblique mixed instability is proposed, which predicts that spatiotemporal
effects generally prevail for finite-length beams, leading to a significantly
slower instability evolution than in the usually assumed purely temporal
regime. These results are accurately supported by particle-in-cell (PIC)
simulations. Furthermore, we show that the self-focusing dynamics caused by the
plasma wakefields driven by finite-width beams can compete with the oblique
instability. Analyzed through PIC simulations, the interplay of these two
processes in realistic systems bears important implications for upcoming
accelerator experiments on ultrarelativistic beam-plasma interactions
The LUNEX5 project
http://accelconf.web.cern.ch/AccelConf/FEL2012/papers/froa03.pdfInternational audienceLUNEX5 (free electron Laser Using a New accelerator for the Exploitation of X-ray radiation of 5th generation) aims at investigating the production of short, intense, and coherent pulses in the soft X-ray region. The project consists of a Free Electron Laser (FEL) line enabling the most advanced seeding configurations: High order Harmonic in Gas (HHG) seeding and Echo Enable Harmonic Generation (EEHG) with in-vacuum (potentially cryogenic) undulators of 15 and 30 mm period. Two accelerator types feed this FEL line : a 400 MeV Conventional Linear Accelerator (CLA) using superconducting cavities compatible with a future upgrade towards high repetition rate, for the investigations of the advanced FEL schemes; and a 0.4 - 1 GeV Laser Wake Field Accelerator (LWFA), to be qualified in view of FEL application, in the single spike or seeded regime. Two pilot user experiments for timeresolved studies of isolated species and solid state matter dynamics will take benefit of LUNEX5 FEL radiation and provide feedback of the performance of the different schemes under real user conditions
Loss of paraplegin drives spasticity rather than ataxia in a cohort of 241 patients with SPG7
Objective : We took advantage of a large multinational recruitment to delineate genotype-phenotype correlations in a large, trans-European multicenter cohort of patients with spastic paraplegia gene 7 (SPG7).
Methods : We analyzed clinical and genetic data from 241 patients with SPG7, integrating neurologic follow-up data. One case was examined neuropathologically.
Results : Patients with SPG7 had a mean age of 35.5 +/- 14.3 years (n = 233) at onset and presented with spasticity (n = 89), ataxia (n = 74), or both (n = 45). At the first visit, patients with a longer disease duration (> 20 years, n = 62) showed more cerebellar dysarthria (p < 0.05), deep sensory loss (p < 0.01), muscle wasting (p < 0.01), ophthalmoplegia (p < 0.05), and sphincter dysfunction (p < 0.05) than those with a shorter duration (< 10 years, n = 93). Progression, measured by Scale for the Assessment and Rating of Ataxia evaluations, showed a mean annual increase of 1.0 +/- 1.4 points in a subgroup of 30 patients. Patients homozygous for loss of function (LOF) variants (n = 65) presented significantly more often with pyramidal signs (p < 0.05), diminished visual acuity due to optic atrophy (p < 0.0001), and deep sensory loss (p < 0.0001) than those with at least 1 missense variant (n = 176). Patients with at least 1 Ala510Val variant (58%) were older (age 37.6 +/- 13.7 vs 32.8 +/- 14.6 years, p < 0.05) and showed ataxia at onset (p < 0.05). Neuropathologic examination revealed reduction of the pyramidal tract in the medulla oblongata and moderate loss of Purkinje cells and substantia nigra neurons.
Conclusions : This is the largest SPG7 cohort study to date and shows a spasticity-predominant phenotype of LOF variants and more frequent cerebellar ataxia and later onset in patients carrying at least 1 Ala510Val variant
- …