22 research outputs found
Cherenkov Radiation from Pairs and Its Effect on Induced Showers
We calculate the Cherenkov radiation from an pair at small
separations, as occurs shortly after a pair conversion. The radiation is
reduced (compared to that from two independent particles) when the pair
separation is smaller than the wavelength of the emitted light. We estimate the
reduction in light in large electromagnetic showers, and discuss the
implications for detectors that observe Cherenkov radiation from showers in the
Earth's atmosphere, as well as in oceans and Antarctic ice.Comment: Final version, with minor changes, to appear in PRD. 5 pages with 4
figure
Effect of Disorder on Ultrafast Exciton Dynamics Probed by Single Molecule Spectroscopy
We present a single-molecule study unraveling the effect of static disorder on the vibrational-assisted ultrafast exciton dynamics in multichromophoric systems. For every single complex, we probe the initial exciton relaxation process by an ultrafast pump-probe approach and the coupling to vibrational modes by emission spectra, while fluorescence lifetime analysis measures the amount of static disorder. Exploiting the wide range of disorder found from complex to complex, we demonstrate that static disorder accelerates the dephasing and energy relaxation rate of the exciton
Observation of the Askaryan Effect: Coherent Microwave Cherenkov Emission from Charge Asymmetry in High Energy Particle Cascades
We present the first direct experimental evidence for the charge excess in
high energy particle showers predicted nearly 40 years ago by Askaryan. We
directed bremsstrahlung photons from picosecond pulses of 28.5 GeV electrons at
the SLAC Final Focus Test Beam facility into a 3.5 ton silica sand target,
producing electromagnetic showers several meters long. A series of antennas
spanning 0.3 to 6 GHz were used to detect strong, sub-nanosecond radio
frequency pulses produced whenever a shower was present. The measured electric
field strengths are consistent with a completely coherent radiation process.
The pulses show 100% linear polarization, consistent with the expectations of
Cherenkov radiation. The field strength versus depth closely follows the
expected particle number density profile of the cascade, consistent with
emission from excess charge distributed along the shower. These measurements
therefore provide strong support for experiments designed to detect high energy
cosmic rays and neutrinos via coherent radio emission from their cascades.Comment: 10 pages, 4 figures. Submitted to Phys. Rev. Let
Cerenkov Radiation Energy Transfer (CRET) Imaging: A Novel Method for Optical Imaging of PET Isotopes in Biological Systems
Positron emission tomography (PET) allows sensitive, non-invasive analysis of the distribution of radiopharmaceutical tracers labeled with positron (β(+))-emitting radionuclides in small animals and humans. Upon β(+) decay, the initial velocity of high-energy β(+) particles can momentarily exceed the speed of light in tissue, producing Cerenkov radiation that is detectable by optical imaging, but is highly absorbed in living organisms.To improve optical imaging of Cerenkov radiation in biological systems, we demonstrate that Cerenkov radiation from decay of the PET isotopes (64)Cu and (18)F can be spectrally coupled by energy transfer to high Stokes-shift quantum nanoparticles (Qtracker705) to produce highly red-shifted photonic emissions. Efficient energy transfer was not detected with (99m)Tc, a predominantly γ-emitting isotope. Similar to bioluminescence resonance energy transfer (BRET) and fluorescence resonance energy transfer (FRET), herein we define the Cerenkov radiation energy transfer (CRET) ratio as the normalized quotient of light detected within a spectral window centered on the fluorophore emission divided by light detected within a spectral window of the Cerenkov radiation emission to quantify imaging signals. Optical images of solutions containing Qtracker705 nanoparticles and [(18)F]FDG showed CRET ratios in vitro as high as 8.8±1.1, while images of mice with subcutaneous pseudotumors impregnated with Qtracker705 following intravenous injection of [(18)F]FDG showed CRET ratios in vivo as high as 3.5±0.3.Quantitative CRET imaging may afford a variety of novel optical imaging applications and activation strategies for PET radiopharmaceuticals and other isotopes in biomaterials, tissues and live animals
The development and validation of a scoring tool to predict the operative duration of elective laparoscopic cholecystectomy
Background: The ability to accurately predict operative duration has the potential to optimise theatre efficiency and utilisation, thus reducing costs and increasing staff and patient satisfaction. With laparoscopic cholecystectomy being one of the most commonly performed procedures worldwide, a tool to predict operative duration could be extremely beneficial to healthcare organisations.
Methods: Data collected from the CholeS study on patients undergoing cholecystectomy in UK and Irish hospitals between 04/2014 and 05/2014 were used to study operative duration. A multivariable binary logistic regression model was produced in order to identify significant independent predictors of long (> 90 min) operations. The resulting model was converted to a risk score, which was subsequently validated on second cohort of patients using ROC curves.
Results: After exclusions, data were available for 7227 patients in the derivation (CholeS) cohort. The median operative duration was 60 min (interquartile range 45–85), with 17.7% of operations lasting longer than 90 min. Ten factors were found to be significant independent predictors of operative durations > 90 min, including ASA, age, previous surgical admissions, BMI, gallbladder wall thickness and CBD diameter. A risk score was then produced from these factors, and applied to a cohort of 2405 patients from a tertiary centre for external validation. This returned an area under the ROC curve of 0.708 (SE = 0.013, p 90 min increasing more than eightfold from 5.1 to 41.8% in the extremes of the score.
Conclusion: The scoring tool produced in this study was found to be significantly predictive of long operative durations on validation in an external cohort. As such, the tool may have the potential to enable organisations to better organise theatre lists and deliver greater efficiencies in care
Acute Renal Failure Secondary to Inadvertent Propylene Glycol Overdose with Single-Day High-Dose Vitamin D (Stosstherapy)
Globally, there has been increasing attention paid to vitamin D deficiency and its treatment. Vitamin D stosstherapy with high-dose ergocalciferol in a single day is reemerging as a potential treatment option. We present an as yet unreported complication of acute renal injury due to propylene glycol toxicity in a 7-month infant treated with vitamin D stosstherapy. The product label for the vitamin D used for this patient states it is dissolved in propylene glycol (PG), but the amount is not listed on this or other US ergocalciferol liquid products that contain PG. Caution should be used when considering vitamin D stosstherapy with liquid ergocalciferol products available in the United States